SEREN
TROUBLESHOOTING
Flash Code
Description
1
2
3
4
5
6
7
8
9
10
11
User Fault
Battery Fault
Left Motor Fault
Right Motor Fault
Left Park Brake Fault
Right Park Brake Fault
SHARK Remote Fault
SHARK Power Module
Fault
SHARK
Communications Fault
Unknown Fault
Incompatible Remote
Possible stall timeout or user error.
Release the joystick to neutral and try again.
Try charging the batteries.
Batteries may require replacing.
Check the batteries and cabling.
Check the left motor, connections and
cabling.
Check the right motor, connections and
cabling.
Check the left park brake, connections and
cabling.
Check the right park brake, connections and
cabling.
Check the SHARK Communications Bus
connections and wiring.
Replace the Remote.
Check SHARK connections and wiring.
Replace the Power Module.
Check Battery voltage is greater than 17V.
Check SHARK Bus Cable.
Replace the SHARK Power Module.
Replace the SHARK Remote.
Check all connections and wiring.
Consult a service agent.
The Remote is incompatible with the Power
Module.
Ensure the brand of the Power Module
matches that of the Remote.
Flash codes indicate the nature of an abnormal condition directly from the SHARK lnformation
Gauge. Without the use of any servicing tools, the condition can be simply diagnosed.
18
TROUBLESHOOTING
Instruction Booklet