Elite with Digital Pump

User Manual

Summary of Contents for Elite

Page 1: ...Elite with Digital Pump User Manual ...

Page 2: ...both the prevention and treatment of pressure ulcers in any healthcare environment With a fully encased layer of visco elastic foam beneath the cells for added support the Elite mattress combines a comfortable support surface and alternating therapy suitable for patients at Very High Risk of developing pressure ulcers ...

Page 3: ...Content Fire Warning 3 Safeguards 4 Intended Use 5 Contradictions 5 Installation 6 Pump Functions 7 Mattress Functions 8 Storage 8 Damage Prevention 8 Cleaning 9 Maintenance 11 Technical Description 12 Troubleshooting 13 Warranty 14 ...

Page 4: ...rning could result in a severe fire property damage physical injury or death DO NOT use candles on or around the mattress system DO NOT use electric blankets with this mattress system DO NOT use in the presence of flammable anaesthetics explosions could occur DO keep hot equipment off and away from the mattress surface E g Hair dryer curling tong etc DO keep matches and lighters away from children...

Page 5: ...dropped or damaged or dropped in water return the product to a service centre for examination and repair 5 Keep the cord away from heated surfaces 6 Never block the air opening of this product or place it on a soft surface such as a bed or couch where their openings may be blocked Keep the air opening free of lint hair and other similar particles 7 Never drop or insert any object into any opening ...

Page 6: ...tended Use The Elite Replacement System is intended to reduce the incidence of pressure ulcers while optimising patient comfort It may also be appropriate for the following Individual home care setting and long term care facilities Pain management as prescribed by a healthcare professional Contraindications Users with the following condition could experience contraindications if they use this devi...

Page 7: ...o secure the pump against the foot board to reduce vibration Avoid placing the pump on the floor 6 Join the connectors on the mattress feed pipes to the side of the pump NOTE Ensure the feed pipes on the mattress are not kinked or tucked under the mattress as this will restrict airflow 7 Plug the pump into the mains electrical outlet NOTE Any extra power cord should be neatly arranged and off the ...

Page 8: ...ic All cells in the mattress will be inflated by pressing this button The pump will automatically revert back to alternating mode after 20 minutes Alternate One in two cycle this function will provide optimum pressure relief Patient Weight Settings 10 comfort levels are available for a variety of patient weights Use the to adjust the weight settings accordingly Low Pressure Indicator When low pres...

Page 9: ...and stored in a holdall or bag To prevent mattresses becoming contaminated and or damaged during storage Mattresses should be stored within a polythene cover or bag Do not store other objects such as side rails or bed ends on top of mattresses Allow adequate space for the stored mattresses to be manoeuvred Damage Prevention Take extra care not to puncture the cover and cells as this will allow flu...

Page 10: ...ottom and all four sides of the cover and tube set including under the zip flaps MUST be cleaned The foam used in this product cannot be decontaminated therefore it is recommended that any contamination must result in the foam being replaced WARNING Do not use phenolic or biological based cleaning solutions Do not use any abrasive compounds or cleaning pads Ensure the cover and tube set are comple...

Page 11: ...attress covers can be tumble dried on a low heat setting for 90 minutes Drying temperature must not exceed 40 C Exceeding this temperature can cause significant damage to the mattress cover NOTE Covers must be completely dried before refitting to the mattress inners Biocides This product contains a biocide anti fungal agent to control microbial deterioration The active ingredient is silver phospha...

Page 12: ...ses should be checked regularly to ensure they remain fit for purpose clinically effective and pose no risk of infection to either the patient or the carer Drive DeVilbiss Healthcare Ltd recommend that a thorough inspection of both the interior foam base and cells and exterior cover of the mattress is carried out on a weekly basis or each time a new patient is placed on the mattress Visual checks ...

Page 13: ...Elite Cushion Usage Continuous operation Mattress Specification Dimensions 1880 x 890 x175mm Weight 6Kg Max Patient Weight 190kg Top Cover Material Xtreme fabric PU coated fabric substrate Cell Material Nylon PVC Cell Configuration 16 single cell formation Fire Classification BS5852 BS7175 composite Risk assessment to be carried out Risk Factor Very High Risk with pump Electromagnetic Interference...

Page 14: ...ions along the cells are secure Assess the cells for any punctures which maybe causing a leak Patient is bottoming out Pressure setting may be inadequate adjust comfort range No air is being produced from some of the air outlets of the tube connectors This is normal in alternating mode Air outlets take turns to produce air during their cycle time If fault still continues a Drive DeVilbiss Healthca...

Page 15: ...nship of our products and our assurance to the customer In the event of a defect covered by this warranty we will at our option supply parts or replace the device This warranty does not cover device failure due to owner misuse or negligence or normal wear and tear The warranty does not extend to non durable components such as rubber accessories castors and grips which are subject to normal wear an...

Page 16: ...drivedevilbiss co uk The Team at Drive DeVilbiss develops its products to give our customers the freedom to live independently This encompasses their daily home life and provides them with the opportunity to enjoy an outing with family and friends Our goal is to develop a range that will provide individuals with a chance to enjoy everyday life Leaflet code 6002990011 ...