DRANE-KOOLER

Water tempering device

 Installation, operation and maintenance manual

Summary of Contents for DK-12

Page 1: ...Read and save these instructions DRANE KOOLER Water tempering device Installation operation and maintenance manual ...

Page 2: ...ort group at 800 328 4447 Technicians are available from 7 30 a m to 5 00 p m central standard time Monday through Friday excluding major holidays Visit our web site www dristeem com For information about other DRI STEEM products visit our web site or contact us using the information listed below Corporate headquarters 14949 Technology Drive Eden Prairie MN 55344 952 949 2415 800 328 4447 952 229 ...

Page 3: ...pacities and connection sizes 2 Dimensions 3 Warranty 12 Installation Installation instructions 4 Mounting 5 Piping 6 7 Table of contents Operation Start up and operation instructions 8 Maintenance Maintenance instructions 9 Troubleshooting guide 10 Replacement parts 11 ...

Page 4: ......

Page 5: ...er or other appliance enters the DRANE KOOLER through piping connected to the top threaded connection A vacuum breaker prevents backflow into potable water systems 2 Cold water enters through the temperature actuated valve The valve and the DRANE KOOLER s straightforward design ensure efficient mixing of hot and cold water The valve s sensor located near the outlet ensures that water leaving the D...

Page 6: ...inflow 6 22 7 212 100 Cold water inflow 6 22 7 70 21 Tempered water outflow 12 45 4 140 60 This table applies only if one humidifier is connected to one DRANE KOOLER with no more than 10 3 m of vertical dimension between the humidifier and the DRANE KOOLER If you wish to connect more than one humidifier to a DRANE KOOLER or if you need more than 10 3 m of vertical dimension consult the factory Col...

Page 7: ...w t o h f o p o t o t k n a t f o m o t t o b m o r f t h g i e H 5 7 1 9 1 C e v l a v f o p o t o t k n a t f o m o t t o b m o r f t h g i e H 5 0 1 8 6 2 D e v l a v f o p o t o t t e l n i r e t a w t o h f o p o t m o r f t h g i e H 0 3 6 7 E e l o h g n i t n u o m f o r e t n e c o t k n a t f o m o t t o b m o r f t h g i e H 5 2 6 9 5 1 F t e l t u o r e t a w d e r e p m e t f o r e t ...

Page 8: ...DICATED TO OTHER APPLIANCES If installing the DRANE KOOLER with a humidifier do not branch off the 1 4 DN8 cold water supply line to the humidifier Verify that the supply water pressure to the valve is at least 25 psi 172 kPa and not more than 80 psi 552 kPa Install a cold water supply union as close to the DRANE KOOLER as possible Install a cold water shut off valve before the union in the cold w...

Page 9: ... the DRANE KOOLER will be properly supported and not secured entirely by piping Floor stand and suspension mount hanger assembly are ordered separately Suspension mount The suspension mount hanger assembly includes an L bracket two nuts and two bolts that attach to the DRANE KOOLER Beam clamp assembly and 1 4 threaded rod are supplied by others OM 1115 OM 1116 OM 1114 5 ...

Page 10: ...ATE WATER PRESSURE TO THE DRANE KOOLER DO NOT CONNECT TO A SUPPLY WATER LINE THAT IS DEDICATED TO OTHER APPLIANCES Cold water supply shut off valve 1 25 mm air gap before drain Drain Evaporative humidifier Tempered water drain piping 2 DN50 NPT PIPING MUST BE RUN FULL SIZE TO DRAIN WITH NO REDUCERS Recommended minimum pitch 1 8 per ft 1 Tempered water outlet service union 2 DN50 NPT Anchor mountin...

Page 11: ...Two examples showing the DRANE KOOLER mounted directly underneath an evaporative humidifier OM 1121 OM 1122 DRANE KOOLER DRANE KOOLER Pitch drain piping at least 1 8 ft 1 in direction of arrows Pitch drain piping at least 1 8 ft 1 in direction of arrows 7 ...

Page 12: ...systems 1 2 3 Temperature actuated valve Sensor Capillary tube 2 Cold water enters through the temperature actuated valve The valve and the DRANE KOOLER s straightforward design ensure efficient mixing of hot and cold water The valve s sensor located near the outlet ensures that water leaving the DRANE KOOLER is less than 140 F 60 C before entering the municipal sewer system 3 Tempered water at 14...

Page 13: ... to a service sink Add water and with pipe caps or hands covering the hot water inlet and tempered water outlet shake the DRANE KOOLER to dislodge mineral deposits Dump mineral deposits and rinse q If severe mineral accumulation has occurred remove the thermal sensor from the DRANE KOOLER chamber and gently clean the sensor with an abrasive pad Do not twist the capillary tube during removal or cle...

Page 14: ...er and hot condensate If a large amount of steam enters the DRANE KOOLER it is likely that discharge water temperatures will be greater than 140 F 60 C Check P traps on humidifier or other appliance to ensure that the P traps have the proper depth and are working properly to prevent steam from entering the DRANE KOOLER If steam is entering the DRANE KOOLER the introduction of cold water through th...

Page 15: ...0 1 0 7 0 5 2 3 s s a r b 4 x T P N 4 1 e l p p i N 4 0 0 2 1 2 0 5 2 4 r e c u d e r x e h 4 1 x 8 3 g n i h s u B 1 0 0 0 5 5 3 0 2 5 g n i t a u t c a f l e s c i r t c e l e n o n e v l a V 1 0 0 0 9 0 5 0 5 6 f e i l e r m u u c a v 6 3 N 2 1 e v l a V 0 0 4 0 2 3 7 y l b m e s s a d n a t s r o o l F 0 1 1 5 8 1 8 y l b m e s s a r e g n a h t n u o m n o i s n e p s u S 0 0 1 5 8 1 DRANE KO...

Page 16: ...STEEM s limited warranty shall not be effective or actionable unless there is compliance with all installation and operating instructions furnished by DRI STEEM or if the products have been modified or altered without the written consent of DRI STEEM or if such products have been subject to accident misuse mishandling tampering negligence or improper maintenance Any warranty claim must be submitte...