Stream height is factory set at 35 PSI. If supply pressure varies

greatly from this, remove Items 1 & 2 and adjust screw on

Item 4. Clockwise adjustment will raise stream and counter-

clockwise adjustment will lower stream. For best adjustment,

stream should hit basin approximately 6-1/2" (165mm) from

bubbler.

BASIN

FIG. 3

NOTE:

WHEN INSTALLING REPLACEMENT

BUBBLER AND PEDESTAL, TIGHTEN NUT

(ITEM 12) ONLY TO HOLD PARTS SNUG IN

POSITION. 

DO NOT OVER TIGHTEN.

FIG. 4

BASIN

9

10

11

12

8

4

3

1

5

6

2

WIRING DIAGRAM

This Drawing is merely for illustrating the

components of the electrical system.

22111C

22112C

22113C

30980C

31386C

31428C

50787C

70606C

70607C

70640C

70659C

70683C

70793C

22588C

1

2

3

4

5

6

7

8

9

10

11

12

13

NS

PART. NO.

DESCRIPTION

ITEM NO.

HOT TANK PARTS LIST

Heater Clamping Bracket

Heater Clamping Bracket (thrd)

Retaining Bracket

Heater Element & Jacket

Tank & Tube Assy

Hot Control Assy

Washer-Spacer

Drain Plug

Screw 1/4-20 x 3.00" HSHC

Screw #8-18 x 5/16" HHTC

Belleville Washer

1/4 Union

1/4 Elbow

Hot Tank Mounting Bracket

FIG. 5

35

36

38

40

37

39

SERVICING THE HOT CONTROL AND FUSE ASSEMBLY

1.  A temperature sensing non-resetable fuse in the wire is located approximately 3" (76mm) from the thermostat.

    The fuse is located under the retaining bracket (Item 3) in the groove on the heater element jacket (Item 4).

2. The thermostat must be used with a washer-spacer (Item 7) and be centered in the heater element jacket for

    proper temperature control.  Locate the heater element jacket about 3/4" (19mm) above the bottom of the tank.

3. The heater element jacket must be fastened 

VERY TIGHTLY

 to the tank (45+/-10 inch-lbs. of torque on the mounting

     screw Item 9).  Failure to 

TIGHTEN

 heater element jacket may cause rapid failure of the fuse assembly.

10

3

6

7

9

11

1

2

8

13

4

5

12

Summary of Contents for Space-ette FHD7005 10 1C

Page 1: ...C FHD7005 3C THAD5H 1C PAGE 1 Space ette With FLEXI GUARD Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 34 SEE FIG 5 SEE FIG 3 7 26 43 44 14 SEE FIG 4 45 18 16 27 28 15 41 42 22 23 24 25 46 31 32 13 33 SEE PAGE 3 30 19 17 20 29 21 ...

Page 2: ...8mm DEPUIS LE ROBINET D ARRET FOURNI PAR D AUTRES B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN UBICACIÓN RECOMENDADAPARAEL DRENAJE DE SALIDA DE AGUA DE 1 1 4 DE DIÁMETRO EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 4 DE SORTIE D EAU C 1 1 4 TRAP NOT FURNISHED PURGADOR DE 1 1 4 NO PROPORCIONADO SIPHON 1 1 4 NON FOURNI D INSURE PROPER VENTILATION BY MAINTAINING 4 102mm MIN CLEARANCE FR...

Page 3: ...ANK PARTS LIST Heater Clamping Bracket Heater Clamping Bracket thrd Retaining Bracket Heater Element Jacket Tank Tube Assy Hot Control Assy Washer Spacer Drain Plug Screw 1 4 20 x 3 00 HSHC Screw 8 18 x 5 16 HHTC Belleville Washer 1 4 Union 1 4 Elbow Hot Tank Mounting Bracket FIG 5 35 36 38 40 37 39 SERVICING THE HOT CONTROL AND FUSE ASSEMBLY 1 A temperature sensing non resetable fuse in the wire ...

Page 4: ...ssy Housing Assy Pedestal Bubbler Locknut Cold Control Power Cord Condenser 5GPH Condenser 10GPH Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier 5GPH Drier 10GPH Compressor Serv Pak PW3HK7 5GPH Compressor Serv Pak FF7 5HBK 10GPH Compressor Serv Pak EM65 10GPH Overload Relay Assy 1 350 398 5GPH Overload Relay Assy 1 350 358 10GPH Overload Relay Assy P600B 427NFBYY 10GPH Cover Relay C...

Reviews: