background image

97377C (Rev. D - 8/01)

ESRC8*1E   ESRC13*1E, 2E, 3E

PAGE 2

FIG. 2

*

RECOMMENDED HEIGHT FOR ADULTS. DECREASE HEIGHT FOR CHILDREN.

*

ALTURA RECOMENDADA PARA ADULTOS. REDUZCA PARA LOS NIÑOS.

*

HAUTEUR RECOMMANDÉE POUR LES ADULTES.  INSTALLEZ PLUS BAS POUR LES ENFANTS.

FINISHED FLOOR

PISO ACABADO PLANCHER FINI

MOUNTING BOX

SHIPPING POSITION OF FASTENING CLIP

COOLER BASE

POSITION FASTENING CLIP AS SHOWN AFTER COOLER IS HUNG IN PLACE

DETAIL A

DETAIL B

SEE DETAILS A & B

MOUNTING BOX

ROUGH-IN

D = ELECTRICAL

 OUTLET LOCA

TION

UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT

E = INSURE PROPER VENTILA

TION BY

 MAINT

AINING 

4" 

(102mm) 

(MIN.) 

CLEARANCE

      FROM CABINET LOUVERS TO WALL.

ASEGURE UNA

 VENTILACIÓN 

ADECUADA

 MANTENIENDO UN ESP

ACIO E 4" (102mm) (MÍN.)

DE HOLGURA

 ENTRE LA

 REJILLA

 DE VENTILACIÓN DEL

 MUEBLE Y

 L

PARED

ASSUREZ-VOUS UNE BONNE VENTILA

TION EN GARDANT

 4

" (102mm) (MIN.)

ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.

F = POWER CORD 1-1/2FEET (457mm) LONG

CABLE ELÉCTRICO DE 1½ PIE, 457 mm DE LARGO CORDON 

D’ALIMENT

ATION 1-1/2' (457mm)

LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W

ATER SUPPL

Y LOCA

TION 3/8 O.D. UNPLA

TED COPPER TUBE CONNECT STUB 1-1/2 IN. (38 m

m

) O

U

T

FROM WALL SHUT OFF BY OTHERS

 SE RECOMIENDA

 UBICAR EL

 TUBO 

COR

TO

 DE CONEXIÓN 

A

TUBO DE COBRE SIN CHAP

AR DE 3/8" DE DIÁM. EXT

. A

 1-1/2"

(38 

m

m

) FUERA

 D

E

 L

A LLA

V

E

 D

E

 P

ASO EN LA

 P

ARED 

COLOCADA

 POR 

TERCEROS.

        EMPLACEMENT 

RECOMMANDÉ 

D'ALIMENT

ATION 

EN 

EAU 

PA

R

 TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 m

m

) D.E.

CONNECT

A

N

UNE 

TU

YAUTERIE DE 1-1/2 PO. (38 m

m

) DEPUIS LE ROBINET D'ARRÊT

 FOURNI P

AR D'AUTRES.

B = RECOMMENDED LOCA

TION 

FOR 

W

ASTE OUTLET 1-1/4” O.D.  DRAIN

 UBICACIÓN RECOMENDADA

 P

A

R

E

DRENAJE 

DE 

SALIDA

 D

E

 AGUA, DE 1¼” DE DIÁMETRO.

EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.

C = 1-1/4 TRAP NOT FURNISHED**

PURGADOR DE 1¼ NO PROPORCIONADO** SIPHON 1-1/4 NON FOURNI**

All manuals and user guides at all-guides.com

Summary of Contents for ESRC8 1E Series

Page 1: ... Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 SEE FIG 3 SEE DETAIL ABOVE 26 6 2 43 8 See Fig 4 42 7 14 41 18 15 16 17 28 25 37 13 23 44 22 30 29 1 27 19 20 21 3 4 5 39 24 45 40 38 46 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...ONNE VENTILATION EN GARDANT 4 102mm MIN ENTRE LES ÉVENTS DE L ENCEINTE ET LE MUR F POWER CORD 1 1 2FEET 457mm LONG CABLE ELÉCTRICO DE 1 PIE 457 mm DE LARGO CORDON D ALIMENTATION 1 1 2 457mm LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38 mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COB...

Page 3: ...t water inlet line See Note 4 of General Instructions 7 Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap Assemble the slip nut and gasket to the trap and tighten securely START UP Also See General Instructions 8 Replace the front panel and secure by retightening all screws FIG 4 10 11 12 8 9 WRAPPER...

Page 4: ...Ferrule Tailpipe Tailpipe Gasket Angle Front Corner Bracket Basin Mounting Frame Back Bottom Bracket Front Locknut Fitting Elbow 1 4 Stem 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK IL PRINTED IN U S A 220 240V 50Hz 31506C 31430C 35763C 31024C 66552C Power Co...

Reviews: