Drinking Fountain Doctor EHOA8 1G Installation Use And Care Manual Download Page 3

98061C (Rev. A - 8/05)

EHOA8*1G    EHOA8*2GJO

PAGE 3

SENSOR RANGE ADJUSTMENT

:  The electronic sensor used in this cooler is factory pre-set for a "visual" range of 36

     inches (914 mm).  If actual range varies greatly from this or a different setting is desired, follow the range adjustment
     procedure below:
A.  Remove front panel of cooler.
B.  Using a small tip screwdriver, rotate range adjustment screw clockwise to increase range and counterclockwise to
     decrease range (See Fig. 3).

     CAUTION

:  Complete range of sensor (24-46 inches/610-1168mm) is only one turn of the adjusting screw.

C.  Replace front panel.

SENSOR CONTROL

:  If sensor fails to operate valve mechanism or operates erratically, check the following.

A.  Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler.
B.  Check wire connections at the solenoid valve and sensor.  

CAUTION

:  Make sure unit is unplugged before checking any

     wiring.
C.  Ensure proper operation of solenoid valve.  If there is an audible clicking sound yet no water flows, look for an obstruction
     in the valve itself or elsewhere in the water supply line.

13

14

10

6

FIG. 3

HANGER BRACKETS & TRAP

INSTALLATION

1

) Remove hanger brackets fastened to back of cooler by

removing one (1) screw.

2) Mount the hanger brackets and trap as shown in Figure 2.

NOTE:

  Hanger Brackets MUST be supported securely.  Add

fixture support carrier if wall will not provide adequate
support.

IMPORTANT:

y

Anchor hanger securely to wall using all six (6) 1/4 in. dia.

mounting holes.

3) Install straight valve for 3/8" O.D. unplated copper tube.

INSTALLATION OF COOLER

4) Hang the cooler on the hanger brackets.  Be certain the

hanger brackets are engaged properly in the slots on the
cooler back as shown in Figure 2.

5) Loosen the two (2) screws holding the lower front panel at

the bottom of cooler base.  Remove the front panel and
set aside.

6) Connect water inlet line--See Note 4 of General Instruc-

tions.

7) Remove the slip nut and gasket from the trap and install

them on the cooler waste line making sure that the end of
the waste line fits into the trap.  Assemble the slip nut and
gasket to the trap and tighten securely.

START UP

Also See General Instructions

8) Stream height is factory set at 35 PSI.  If supply

pressure varies greatly from this, adjust screw, ac-
cessible by removing front panel (Item 7, Fig. 3).  CW
adjustment will raise stream and CCW adjustment
will lower stream.  For best adjustment, stream should
hit basin approximately 6-1/2” (165mm) from bub-
bler.

9) Replace the front panel and secure by retightening

two (2) screws.

ITEM NO.

PART NO.

Panel-Bottom Dispenser
Bracket-Valve Mounting
Sensor-Clear (115V & 230V)
Solenoid Valve (115V)
Solenoid Valve (230V)
Panel-Right Side
Panel-Left Side
Panel-Front
Elbow 1/4 Stem x 1/4 O.D.
Fitting 1/4 NPTF x 1/4 O.D.
Nut-Regulator
Screw-#6-32 x 1/2" Lg. PHMS
Screw-#10 x 1/2" Lg. PHSM
Hex Nut
Screw-#8 x 5/8" Lg. Torx/Slot
Holder-Regulator
Regulator
Screw-#10 x 1/2" Lg. HHSM

26588C
26866C
36028C
31272C
35784C

See Color Table
See Color Table
See Color Table

70817C
75507C
56082C
70644C
75497C
40045C
70864C
50986C
61314C
70002C

Item No. 5

Part No.

COLOR TABLE

Gray Beige
Almond
Stainless Stl
Sandalwood
Granite
Light Gray

26635C
26636C
26637C
26638C
26641C
26642C

26605C
26606C
26607C
26608C

26611C

26612C

26731C
26732C
26733C
26734C
26737C
26738C

PANEL

COLOR

Item No. 6

Part No.

Item No. 7

Part No.

11

2

9

4

12

1

1
2
3
4

5
6
7
8
9

10
11
12
13
14
15
16
17

DESCRIPTION

NOTE:  WATER FLOW DIRECTON

RANGE ADJUSTMENT SCREW

3

16

15

14

7

14

5

9 17

8

Summary of Contents for EHOA8 1G

Page 1: ...1G EHOA8 2GJO PAGE 1 With FLEXI GUARD Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 51 34 42 52 39 40 41 50 26 51 25 53 21 53 35 36 37 48 20 18 33 22 23 24 38 49 54 SEE FIG 3 43 44 45 46 56 55 19 27 47 SEE FIG 4 ...

Page 2: ...URA DEL ORIFICIO 1 1 4 32mm SOBRE LA CORONA HAUTEUR DE L ORIFICE 1 1 4 32mm AUDESSUS DU REBORD LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38mm FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR...

Page 3: ... are engaged properly in the slots on the cooler back as shown in Figure 2 5 Loosen the two 2 screws holding the lower front panel at the bottom of cooler base Remove the front panel and set aside 6 Connect water inlet line See Note 4 of General Instruc tions 7 Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits int...

Page 4: ...t Hanger 27097C See Color Table 36208C 27095C 30664C 70018C 31490C 70009C 56237C 70142C 56073C 40322C 55997C 56011C 75580C 66743C 66703C 50144C 70184C 70150C 36094C 36158C 35768C 35959C 66576C 40572C 40575C 50074C 21222C 75536C 31513C 66534C 55996C 27093C 27094C 27096C 56092C 20430C 20774C WRAPPER COLOR DESCRIPTION INCLUDES RELAY OVERLOAD IF UNDER WARRANTY REPLACE WITH SAME COMPRESSOR USED IN ORIG...