User manual
BUILT
– IN GAS STOVE | TURIN 60
12
6.
BURNERS AND NOZZLE SPECIFICATIONS
ADAPTING THE GAS HOB FOR DIFFERENT TYPES OF GAS
At 15°C and 1013 mbar - dry gas
P.C.I.G20 37.78 MJ/m³ P.C.I.G25.1 32.51 MJ/m³
P.C.I.G25 32.49 MJ/m³ P.C.I.G27 30.98 MJ/m³
P.C.I.G2.350 27.20MJ/ m³ P.C.I.G30 49.47MJ/Kg
Replacement of burner nozzle: loosen the nozzle with a dedicated wrench (7).Fit the new
nozzle according to the required gas type (see table 1 for reference)
。
After you have converted the gas hob to another gas type, make sure you have placed a label
containing that information on the appliance.
G20
G30
Burner
Thermal
power (kW)
Nozzle 1/100
(mm)
Thermal power (kW)
Nozzle 1/100 (mm)
Auxiliary (Small) (A)
1.0
71
1.0
52
Semi rapid (Medium)
1.80
97
1.8
67
Rapid (R)
2.40
110
2.40
77
Triple Ring (TR)
3.40
125
3.40
93
Supply pressures
20mbar
30mbar