User manual
ELECTRIC IN BUILT OVEN | ITALIA 94
Professionale
25
Panels adjacent cabinets must be of heat resistant material .In particular, veneered
cabinets must be mounted with tires that can withstand temperatures up to 100
℃
.
In compliance with current safety standards, contact with the electrical parts of the
oven should not be possible until the installation is not completed.
All parts which ensure the safe operation must be removable only with the aid of a
tool.
To hold the oven cabinet, open the oven door and attach by inserting screws 4 into
the 4 holes on the frame perimeter.
Power cable connection to the mains
When connecting the cable directly to the network, install a pole switch with a
minimum contact opening of 3 mm between the appliance and the mains pole .The
switch must be sized according to the load and comply with current regulations (the
ground wire must not be interrupted by the switch).
The power cord should be positioned so that a temperature of over 50
℃
is reached
with respect to the protected insulation room temperature, anywhere along its
length, or having an appropriate rating.
Before making the connection checks the following:
The electrical safety of the appliance can only be guaranteed if the oven is set to
land correctly and efficiently, in compliance with regulations on electrical safety.
Always make sure the ground wire is efficient; if you have any questions call a
qualified technician to check the system .The manufacturer will not be responsible
for damage resulting from a system that has not been grounded.
Before connecting the appliance to the mains, check that the data shown on
the plate (in the apparatus and / or packaging) correspond to the power
system of home.
Check that the electrical capacity of the system and sockets will support the
maximum power of the appliance, as indicated on the nameplate if you have
any questions, call a technician.
220-240 V operation
~: Use H05RR-F type three-wire cable (3 x 2.5
mm²).