Dri-Eaz TurboDryer Sahara E Owner'S Manual Download Page 2

07-01758B 

Legend Brands, Inc. 

used with adequate dehumidification. To help control mould 
growth, keep indoor humidity below 60% RH. If possible, 
maintain indoor humidity below 45% RH. This may require 
the use of DrizAir Refrigerant Dehumidifiers.  

To improve drying, close off the area being dried from the 
rest of structure. Regulate the heating or air conditioning 
system at 20

–27°C. When dehumidifiers are not available, 

run exhaust fans in the attic, kitchen and bathroom to 
remove some humidity. If outdoor air is very dry, open some 
windows or doors at least slightly. Use a thermo-hygrometer 
to determine the relative humidity.  

Check if Materials are Dry 

Monitor the moisture condition of wet materials with moisture 
meters. To check how completely materials have dried out, 
compare your readings to readings you take on similar 
materials you know are dry. 

Cooling & Ventilation 

Over-heated rooms can be cooled with high-volume airflow 
from a TurboDryer. Place the airmover on the floor or other 
flat surface and direct the air from cooler areas or the out-
doors. Use the kickstand or tilt the unit to a 45 or 90 degree 
angle to elevate the snout and circulate cool air throughout 
the room. 

OPERATING INSTRUCTIONS 

1.  Plug in to a standard outlet with the correct voltage and 

amperage for the unit. Set the switch at the desired 
speed. Check for proper operation before leaving the unit 
unattended. 

2.  Do not move or carry the TurboDryer when it is running. 

ELECTRICAL CONNECTIONS 

TurboDryers are designed to operate on a 230V/50 Hz 
electrical connection. Make sure that the electrical outlet is 
grounded and that all safety precautions are taken.  

MAINTENANCE 

Always turn off the power before performing maintenance 
procedures. All the service procedures below are to be 

executed with the unit unplugged. Perform before each use 
or as needed. 

INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord 
for damage at regular intervals. Periodically, remove the 
housing and inspect internal wiring for bare wires, insecure 
fasteners, and discoloration. Remove and repair any dam-
aged wiring as needed. Failure to do so may lead to 
electrical shock or a fire hazard. 

CLEAN AIR INTAKES: Clean off any accumulated lint or 
other materials from the air inlet side-screens. A buildup will 
reduce the airflow and may cause the motor to overheat and 
become a fire hazard.  

CLEAN EXTERIOR: Clean the housing with mild detergent 
and water. Bring back the original shine with a vinyl cleaner 
and polish like those used on automobile plastics. 

EXTERIOR INSPECTION: Evaluate exterior components 
and make sure they are properly installed. Listen to the unit 
for abnormal sounds. Repair or replace components as 
needed. 

Periodic Maintenance (as needed) 

Make sure unit is unplugged and the wheel has stopped. 
Remove four screws to remove each side screen. This will 
permit access to motor and wheel for cleaning.  

CLEAN COMPONENTS: Use compressed air or a vacuum 
to remove lint and dust from blower wheel, motor and side 
screens. 

DO NOT WET MOTOR OR WIRING: To prevent damage to 
electrical components, do not use a hose or pressure washer 
to clean a TurboDryer. If electrical components do become 
wet, dry them immediately.  

MOTOR BEARINGS: The bearings on all Dri-Eaz Turbo-
Dryers are permanently lubricated. Do not oil. 

 

WARRANTY 

TO  REQUEST  WARRANTY  SERVICE:  Write  or  call  your 
Dri-Eaz distributor for instructions.  

 

CONTACT 

For product information, service and warranty repairs, 
contact your Dri-Eaz distributor.  
 

Dri-Eaz Products, Inc.  

15180 Josh Wilson Road 

• Burlington, WA USA 98233 

Fax US: 360-757-7950 

• Phone US: 360-757-7776      

www.dri-eaz.com.  