The Dri-Eaz

®

 Cube Dehumidifier reduces humidity in enclosed environments by removing water vapor 

from the air. The Cube is ideal for water damage restoration, structural drying, construction, and many 
other applications requiring temporary, high-performance dehumidification.  

Patents: http://www.LBpatents.com 

S A V E   T H E S E   I N S T R U C T I O N S

 

 

 

 

 

Read and understand manual before operating. 

 

 

 

 

 

SAFETY INSTRUCTIONS 

WARNING! Do not alter or modify your unit in any 
way. Use only replacement parts authorized by 
Dri-Eaz Products, Inc. Modifications or use of unap-
proved parts could create a hazard and will void 
your warranty. Contact your authorized distributor 
for assistance. 

WARNING! Electric shock hazard, rotating fan, hot 
surface hazards. Unplug unit before opening cover 
for cleaning or servicing. Unit must be grounded. 

  Inspect the power cord before use. If cord is dam-

aged, do not use. Always grasp the plug (not the 
cord) to unplug. 

  Insert three-prong plug on power cord into a match-

ing electrically grounded outlet. Do not use adapter. 
Never cut off third prong. Do not use an extension 
cord.  

  The unit must be operated on a 115V/60Hz circuit 

protected by a Ground Fault Circuit Interrupter 
(GFCI) device.  

  Keep motor and wiring dry. 

  Do not attempt to repair the unit. For Authorized 

Service Centers, contact Dri-Eaz.  

BEFORE YOU BEGIN 

Warranty registration 

Visit 

warranty.drieaz.com

 to register your purchase. 

Registration allows us to better assist you with using, 

maintaining or servicing your equipment and to contact 
you in case we have important safety information con-
cerning your Dri-Eaz product. If you determine service is 
required, have your equipment model, serial number and 
original proof of purchase available and call your distrib-
utor for assistance with obtaining a return material au-
thorization (RMA). 

 

INTRODUCTION 

The Cube Dehumidifier reduces humidity in enclosed 
structural environments by removing water vapor from 
the air. With proper use, the Cube can help to dry out 
damp structural materials, insulation, and contents, and 

WARNING

 

Carry handles 

Fig. A: Parts Identification 

Air inlet 

Control 
panel 

Air outlet 
(both sides) 

Cord and 
hose storage 
compartment. 

Air outlet 
(both sides)

 

Remove/Insert 
air filter here.

 

Summary of Contents for F571-115V

Page 1: ...plug not the cord to unplug Insert three prong plug on power cord into a match ing electrically grounded outlet Do not use adapter Never cut off third prong Do not use an extension cord The unit must...

Page 2: ...20 ft 6 m above the bottom of the unit Also check for kinks or other obstruc tions that might restrict the flow of water Obstructions may cause a water backup and result in overflows Plug in electrica...

Page 3: ...he unit completes the compressor delay the display shows UNIT ON XX HRS and cycles between INLET XX F and INLET XX NOTE If no compressor delay countdown is displayed a delay is not necessary and the m...

Page 4: ...T OUTLET 100 80 115 30 For information only 3 GRAIN DPR XX GPP XX X g kg for 230V models 4 FILTER CLEANED XXX HRS 5 FILTER CLEANED 0 HRS Press to clear filter hours 5 COIL CLEANED XXX HRS 5 COIL CLEAN...

Page 5: ...ensure any water re maining on interior surfaces falls into the sump area 3 Press the PURGE key When the purge cycle is complete turn the unit off 4 Remove the external drain hose drain it carefully c...

Page 6: ...ck valve and pump basin may need to be cleaned Remove grills and cover as shown in Fig B Remove screws from pump base and lift out pump Wipe out pump basin with a damp cloth Inspect the pump base for...

Page 7: ...ture and in let RH every 2 seconds None HUMIDISTAT INLET XXX F XX First line indicates unit is in humidistat mode Second line Toggles between inlet temperature and in let RH every 2 seconds None LOW T...

Page 8: ...or ER4 OUTLET SENSOR CONNECT Temp sensor is open missing or shorted Check that temp sensors are installed cor rectly on control panel If error persists contact service ER5 SENSOR CONNECTION ON BD Inl...

Page 9: ...essary Check coils Clean as necessary If the problem you are experiencing is not listed here call your local distributor or contact our Service Department toll free at 800 932 3030 for further assista...