background image

07-01712C 2010-10 Warranty 07-00420 

Dri-Eaz Products, Inc.  

 

 ON-OFF. Press the ON-OFF key to turn the unit on 

or off. When turning the machine on, usually the display 
reads CMPRSR DELAY and performs a numeral count 
down from a maximum of 60 seconds to 0. The 
compressor delay gives the machine time to warm up 
(when needed). If you don’t see a compressor delay 
countdown, the machine is ready to go. Once the unit 
completes the CMPRSR DELAY, the display reads 
DEHUMIDIFIER ON, and continues to cycle between 
TOTAL HOURS, JOB HOURS and DEHUMIDIFIER ON.  
Press the ON-OFF key again to turn the unit off. The 
display will read DEHUMIDIFIER OFF. 
 

 DISPLAY. Press the DISPLAY key to stop the 

display at DEHUMIDIFER ON or OFF, TOTAL HOURS, 
or JOB HOURS as it cycles. Press DISPLAY again to re-
start the display cycle. 

 
How to change the language display 

 
CAUTION: While in the change-language mode, 
pressing other keys can change the programming of the 
machine. Do NOT press other keys you’re not instructed 
to press. 
 
Use the DISPLAY key to change the display language.  
Follow these steps: 

1. Unplug the unit. 

2. While holding down the DISPLAY key, plug the unit in. 
The display reads ENGLISH. 

3. To change to FRANCAIS, DEUTSCH, or ESPANOL, 
press the DISPLAY key or the CLEAR key.   

4. When the desired language is shown in the display, 
unplug the unit, and the language is set. 

 

CLEAR. Press the CLEAR key to reset the JOB 

HOURS 

1. As the display cycles between DEHUMIDIFIER ON, 
JOB HOURS, and TOTAL HOURS, press the DISPLAY 
key when JOB HOURS appears on the screen. That will 
make the display read JOB HOURS steadily.  

2. Then press the CLEAR key to re-set the numerals 
to 00000.  

3. Press DISPLAY again to re-start the display cycle. 
NOTE: the TOTAL HOURS reading cannot be re-set. 
 

PURGE. Press the PURGE key to empty water 

from the pump reservoir. During normal operation, the 
pump purges automatically every six minutes, or 
whenever the reservoir is full. The display will read 
PUMP PURGING with a numeral countdown. To purge 
the pump manually: 

1. Turn the power off using the OFF key, and let the unit 
sit plugged in for about 10 minutes. This allows water to 
drip from the coils and collect in the drip pan. 

2. Press PURGE to remove residual water. 
 

Defrost mode 

During normal operation, the temperature sensor detects 
frost forming on the coils, causing a defrost cycle to 
start. The display will read DEFROST ON. 
Dehumidification stops during the defrost cycle. When 
the unit completes the cycle, the display returns to 
DEHUMIDIFIER ON. 

 
Error messages 

If the DrizAir’s onboard diagnostics discover a problem, 
the unit will display “GET SERVICE,” followed by "ER” 
and a numeral from 01 to 09. If this message appears, 
first follow these steps:  

1. Unplug the unit and then plug it back in. This may re-
set the electronics. 

2. If the error message reappears, try the solution (if one 
is listed) in the “Error Messages,” 5. 

3. If the error message still appears, please contact the 
Dri-Eaz Service Department at 800-932-3030.  

 

At the end of the job 

As with all dehumidifiers, once the drying job is 
completed, it is important to make sure the unit is 
completely purged of water before moving it. 

To ensure 

that all water has drained into the pump, turn the 
unit off, allow it to rest for 10 minutes, then press the 
PURGE button. 

(The unit must be plugged in for the 

purge to operate.) Once the purge cycle is complete, 
unplug the unit and remove it promptly from the job.  

Before transporting, be sure to remove the external drain 
hose, drain it carefully, and return it to the pocket 
provided on the front of the unit. 

MAINTENANCE 

WARNING! ELECTRIC SHOCK HAZARD.

 Unplug 

the DrizAir before performing any maintenance. 

Before each use 

Inspect the electrical cord for damage.

 Look for 

fraying, cuts, etc. Do not use the unit if you find any 
damage. Call Dri-Eaz for the nearest Service Center at 
800-932-3030. 

Inspect and vacuum filter as needed.

 Keep a clean 

filter in the unit at all times to protect internal 
components from dust and other particulate build-up. 
The DrizAir is equipped with a 3M™ High Air-Flow filter. 
The HAF filter may be vacuumed clean and reused up to 
three times. 

Do not rinse or wash the HAF filter

, as it 

will reduce the effectiveness of the electrostatic material.  

Summary of Contents for DrizAir F232-A GG

Page 1: ...well as to contact you in case we have important safety information concerning your Dri Eaz product If you determine service is required have your equipment model serial number and original proof of...

Page 2: ...d end in a sink drain bucket or outside anywhere that water can drain out safely If you use a bucket or other receptacle for water collection check it regularly to prevent spills NOTE Uncoil and strai...

Page 3: ...Turn the power off using the OFF key and let the unit sit plugged in for about 10 minutes This allows water to drip from the coils and collect in the drip pan 2 Press PURGE to remove residual water De...

Page 4: ...eing careful not to let the nozzle touch the fins as that may cause damage by bending them Check catch basin tray Clean when dirt and debris are present 1 Wipe clean with a rag Check drain hose 1 Look...

Page 5: ...or kinks in the drain hose TROUBLESHOOTING F A U L T C A U S E S O L U T I O N Unit does not operate No power to machine Unit not switched on Plug in unit check power at outlet and at base of unit Sw...

Page 6: ...day Water removal max 90 F 90 RH 200 pts 88 5 liters day Water removal 80 F 20 RH 16 pts 7 6 liters day Max process air 360 CFM 612 CMH Operating Range 33 100 F 1 38 C Air filter 3M HAF filter part no...

Page 7: ...az Products Inc PURCHASE Purchase date ________________________ Serial number ________________________ Distributor ________________________ Tel _________________________ MAINTENANCE D A T E S E R V I...

Reviews: