background image

07-01712C 2010-10 Warranty 07-00420 

Dri-Eaz Products, Inc.  

Owner’s Manual 

DrizAir® Dehumidifier 115V (F232-A GG) 

 

DRI-EAZ PRODUCTS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233 

Phone: 800-932-3030

 

Fax: 360-757-7950

 

www.dri

-

eaz.com

  

The DrizAir Dehumidifier reduces humidity in enclosed structural environments by removing 
water vapor from the air. The DrizAir is engineered to be rugged, durable and highly port-
able, making it ideally suited for construction, remodels, water damage restoration, and 
other applications requiring temporary, high-performance dehumidification.  

 

R E A D   A N D   S A V E   T H E S E   I N S T R U C T I O N S

 

SAFETY INSTRUCTIONS 

 

 

 

 

 

 

WARNING! Electric shock hazard, rotating fan, hot 
surface hazards. Unplug unit before opening cover 
for cleaning or servicing. Unit must be grounded. 

  Inspect the power cord before use. If cord is 

damaged, do not use. Always grasp the plug (not 
the cord) to unplug. 

  Insert three-prong plug on power cord into a 

matching electrically grounded outlet. Do not use 
adapter. Never cut off third prong. Do not use an 
extension cord.  

  The unit must be operated on a 115V/60 Hz circuit 

protected by a Ground Fault Circuit Interrupter 
(GFCI) device.  

  Keep motor and wiring dry. 

  Do not attempt to repair the unit. For Authorized 

Service Centers, call Dri–Eaz at 800-932-3030. 

BEFORE YOU BEGIN 

Unpacking your unit 

Retain all packing material and boxes for possible 
equipment returns.  

Warranty registration 

Visit 

warranty.drieaz.com

 to register your purchase. 

Registration allows us to better assist you with using, 
maintaining or servicing your equipment, as well as to 
contact you in case we have important safety information 

concerning your Dri-Eaz product. If you determine 
service is required, have your equipment model, serial 
number and original proof of purchase available and call 
your distributor for assistance with obtaining a return 
material authorization (RMA). 

 

INTRODUCTION 

Dehumidifiers reduce humidity in enclosed structural 
environments by removing water vapor from the air. With 
proper use, the DrizAir can help dry carpet, carpet pad, 
floors, walls, building contents and more. Using 
dehumidifiers can also help prevent secondary damage 
caused by high humidity. For best results, use the 
DrizAir with Dri-Eaz TurboDryer® airmovers placed 
around the perimeter of the room to distribute heat 
energy and release moisture from wet surfaces into the 
air. 

How the DrizAir dehumidifier works 

Dri-Eaz refrigerant dehumidifiers operate by pulling 
moist air in across a very cold evaporator coil. The 
moisture in the air condenses on the coil. In certain 
conditions, the machine operates in defrost mode, 
warming any frost accumulated on the evaporator coil 
back into water. The water collects in a tray and is 
pumped out through a hose.  
 
IMPORTANT: Before moving the unit, make sure there’s 
no water in the pump. See how to use the PURGE 
function under “How to use the control pad” on page 2.  

POSITIONING A DEHUMIDIFIER 

For best results, operate your dehumidifiers in an 
enclosed area, as this creates a drying chamber. Close 
all doors and windows that open to the outside to 
maximize the unit’s water removal efficiency. Also, keep 
traffic though the drying chamber to a minimum. Place 
your DrizAir dehumidifier against a wall, away from 
obstructions, and keep it away from anything that could 
block airflow into and out of the unit. 

WARNING

 

Summary of Contents for DrizAir F232-A GG

Page 1: ...well as to contact you in case we have important safety information concerning your Dri Eaz product If you determine service is required have your equipment model serial number and original proof of...

Page 2: ...d end in a sink drain bucket or outside anywhere that water can drain out safely If you use a bucket or other receptacle for water collection check it regularly to prevent spills NOTE Uncoil and strai...

Page 3: ...Turn the power off using the OFF key and let the unit sit plugged in for about 10 minutes This allows water to drip from the coils and collect in the drip pan 2 Press PURGE to remove residual water De...

Page 4: ...eing careful not to let the nozzle touch the fins as that may cause damage by bending them Check catch basin tray Clean when dirt and debris are present 1 Wipe clean with a rag Check drain hose 1 Look...

Page 5: ...or kinks in the drain hose TROUBLESHOOTING F A U L T C A U S E S O L U T I O N Unit does not operate No power to machine Unit not switched on Plug in unit check power at outlet and at base of unit Sw...

Page 6: ...day Water removal max 90 F 90 RH 200 pts 88 5 liters day Water removal 80 F 20 RH 16 pts 7 6 liters day Max process air 360 CFM 612 CMH Operating Range 33 100 F 1 38 C Air filter 3M HAF filter part no...

Page 7: ...az Products Inc PURCHASE Purchase date ________________________ Serial number ________________________ Distributor ________________________ Tel _________________________ MAINTENANCE D A T E S E R V I...