Dri-Eaz DriForce XL Owner'S Manual Download Page 2

 

125465A 

Legend Brands, Inc. 

NOTICE: Do NOT use the DriForce XL to extract 

standing water of any kind. Liquid water drawn in 

to the DriForce XL may damage the blower and 

void the DriForce XL warranty. Extract excess 

water with a truckmount or portable extraction 

equipment before attempting to dry. 

The DriForce XL can be used in two ways. 1) As a 

blower, to create high-pressure air (Pressure Mode), 

and 2) as a vacuum blower, to create suction 

(Suction Mode). The DriForce XL is intended for use 

with the Dri-Eaz Air Drying System (ADS) and the 

Dri-Eaz Rescue Mat System.  
For use with the Air Drying System (ADS), see the 

ADS Owner's Manual or visit 

ADS.LegendBrandsRestoration.com

 

For use with the Rescue Mat System, see the 

Rescue Mat System Owner's Manual or visit 

RescueMatSystem.LegendBrandsRestoration.com 

Setup  

Move unit into position.  
IMPORTANT: Lift unit only by frame. Handle 

should only be used for pulling/pushing units 

around and up/down stairs. 
Connect the inlet filter assembly (Fig. A).

 Secure 

in position with cam levers.  

Plug in unit

 to a grounded 115V outlet. 

For use in Suction Mode

, attach either the ADS 

System or the Rescue Mat System to filter hose barb. 

The high temp pressure hose is not used in this 

mode and may be removed.  

IMPORTANT:

 The DriForce XL and Rescue Mat 

System should only be used to remove moisture from 

wood plank floors. 

Do not use on non-porous 

surfaces.

 

IMPORTANT:

 To avoid overheating, do not block air 

inlet or outlet. Ensure that air flows freely at all times 

during operation.  

For use in Pressure Mode, 

attach the black high temp 

pressure outlet hose to the 

Blower OUTLET and clamp 

firmly. Attach either the 

ADS System or the Rescue 

Mat System to the high 

temp hose.  

NOTICE: Use only the 

black high temp hose on 

the Blower OUTLET, 

which produces high heat 

and may damage other 

types of hoses, including 

the hoses supplied with 

the ADS System or the 

Rescue Mat System.

   

Stack units up to two high for storage. See Fig. C.  

MAINTENANCE 

WARNING: Always unplug unit prior to servicing 

or cleaning. 
WARNING: Metal surfaces may become hot 

during operation. Allow unit to cool before 

performing any maintenance.  

After each use 

Check both the inlet and outlet

 for obstructions or 

debris, and clean as needed.  

Clean air inlet filter (Fig. B).

 Unscrew filter cap. If 

cap is too tight to remove by hand, a large wrench 

may be required to unscrew it. Remove filter element 

and use a vacuum cleaner or brush to remove any 

lint or debris. Check that O-ring is intact and properly 

seated before reinstalling the cap. Reassemble 

before use. 

As needed 

When dust is visible,

 clean cooling fan intake cover

 

using a vacuum cleaner and brush tool. 

Parts, service, and warranty information are 

available from your Legend Brands distributor.  

CONTACT 

Legend Brands, Inc.  

15180 Josh Wilson Road 

Burlington, WA 98233 

Phone: 800-932-3030  Fax: 360-757-7950  

LegendBrandsRestoration.com

 

 

SPECIFICATIONS 

Rated airflow 

130 cfm | 221 m

3

/h 

Vacuum (max.) 

84 in. H

2

O | 20.9 kPa 

Static pressure (max) 

88 in. H

2

O | 21.9 kPa 

Dimensions (W × H × D) 

20.8 × 26.3 × 18.4 in.  

52.3 × 66.8 × 46.8 cm 

Weight (w/attachments) 

86.9 lbs. | 39.4 kg 

Amps/Volts/Freq./Power 

12A / 115V / 60Hz / 1.5kW 

Power cord  

25 ft. | 7.6 m Hospital grade 

lighted NEMA 5-15p 

Sound level 

71 dB 

Safety 

ETL listed to UL 507 and 

CSA C22.2 No. 113:15 

 

Fig. C: Stacking 

Fig. B: Cleaning Air Intake Filter 

Disassemble as shown and rinse or vacuum internal filter 

element. Reassemble, making sure O-ring is intact and 

properly seated on cap. Do not overtighten. 

Inspect O-ring 

 

Rinse or vacuum 

filter element.  

Reviews: