cm away from any walls, cabinets, furniture or other
obstructions that might restrict the flow of air.
Do not operate the unit without the filter in place. Avoid
operating the unit in environments that are excessively
dusty. If this is necessary, be sure to clean the filter
more frequently.
Maintenance
AS NEEDED
Clean Filter.
Vacuum the filter first, and then rinse in
clean water. Allow the filter to dry before reinstalling in
the machine.
Clean collection basin and drain hose (if used).
Periodially rinse out the collection basin and allow it to
dry. A mild detergent solution may be used for more
difficult soiling. Inspect the drain hose for any blockages.
Clean exterior housing.
Wipe the housing with a clean
cloth. A mild detergent solution may be used for more
difficult soiling.
SPECIFICATIONS
Model
BD600 Portable Dehumidifer (F509)
Weight
20,5 kg
Dimensions
(D × W × H)
25,5 × 55,0 × 31,0 cm
Operating range
5°
–32° C
Amp
1,5 A
Power
360W / 220
–230V / 50Hz
Sound level (avg.)
73.43 dB
Water removal
AHAM
9 L/day (27°C/60%RH)
Max
19 L/day (32°C/90%RH)
EU standard
7 L/day (20°C/60%RH)
EU standard
15 L/day (30°C/80%RH)
Sound level
55 dB (avg.)
Air movement
158 m³/hr
Water container
capacity
4 l
Refrigerant
R134A
Safety
CE
Specifications are subject to change without notice. Some