Dri-Eaz 108110 (F412) Owner'S Manual Download Page 1

Owner’s Manual 

LGR 7000XLi Portable Dehumidifier 

Model #108110 (F412) 

LEGEND BRANDS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233 

Phone: 800-932-3030

 

Fax: 360-757-7950

 

LegendBrandsRestoration.com

 

The Legend Brands® LGR 7000XLi dehumidifier reduces humidity in enclosed environments by 
removing water vapor from the air. The 7000XLi is rugged, durable and highly portable, making 
it ideal for water damage restoration, structural drying, construction, and other applications 
requiring temporary, high-performance dehumidification.  

Patents: 

http://www.LBpatents.com

 

S A V E   T H E S E   I N S T R U C T I O N S

 

WARNING! Do not alter or modify your unit in any 
way. Use only replacement parts authorized by 
Legend Brands. Modifications or use of unapproved 
parts could create a hazard and will void your 
warranty. Contact your local distributor for 
assistance. 

WARNING! Electric shock hazard, rotating fan, hot 
surface hazards. Unplug unit before opening cover 
for cleaning or servicing. Unit must be grounded. 

  Inspect the power cord before use. If cord is 

damaged, do not use. Always grasp the plug (not 
the cord) to unplug. 

  Insert three-prong plug on power cord into a 

matching electrically grounded outlet. Do not use 
adapter. Never cut off third prong. Do not use an 
extension cord.  

  The unit must be operated on a 120V/60Hz circuit 

protected by a Ground Fault Circuit Interrupter 
(GFCI) device.  

  Keep motor and wiring dry. 

  Do not attempt to repair the unit. For Authorized 

Service Centers, contact Legend Brands.  

NOTICE: Do not use in environments where 
corrosive chemicals are present, such as chlorine. 

INTRODUCTION 

LGR (low-grain refrigerant) dehumidifiers utilize an 
internal pre-cooling system to boost water removal 
efficiency. LGR units can continue to remove moisture in 
drier environments where conventional refrigerants 
cannot. 

 

OPERATING YOUR DEHUMIDIFIER 

Set unit upright 

NOTICE: Transporting or storing the unit in a 
horizontal position is not recommended. When the 
machine is placed in a horizontal position, the oil 
from the compressor can flow into the refrigerant 
coils and reduce the ability of the dehumidifier to 
function and possibly damage the unit. If the unit 
has been placed in a horizontal position, set it 
upright and let it stand for at least 30 minutes before 
turning it on.  

Positioning a Dehumidifier 

For best results, operate your dehumidifiers in an 
enclosed area. Close all doors and windows that 
open to the outside to maximize the unit’s water 

 WARNING 

CORRECT PLUG REMOVAL

 

Grasp IEC plug and pull straight out 

IMPORTANT: Damage to IEC receptacle or 
dehumidifier resulting from improper removal 
of the power cord is not covered by warranty. 
The IEC power cord is a wear item and is not 
covered by warranty.

 

108261Q #108110 (F412) 

Legend Brands, Inc. 

Summary of Contents for 108110 (F412)

Page 1: ...be operated on a 120V 60Hz circuit protected by a Ground Fault Circuit Interrupter GFCI device Keep motor and wiring dry Do not attempt to repair the unit For Authorized Service Centers contact Legen...

Page 2: ...ose Do not leave any part of the hose coiled on the unit and do not place the end of the hose higher than 20 ft 6 m above the bottom of the unit Also check for kinks or other obstructions that might r...

Page 3: ...ce Inlet GPP 1 60 GPP 2 60 90 GPP 3 90 GPP Press MENU to access settings and configuration controls Press PURGE to pump out condensate tank Press ON OFF to turn unit off For detailed control panel ins...

Page 4: ...during transport to prevent sliding and possible injury to vehicle occupants Do not transport or store the unit on its front sides or back This will help to prevent any remaining moisture from escapin...

Page 5: ...not shown Heat exchange block Air filter REAR PANEL Condenser hot coil Evaporator cold coil FRONT COVER Electrical box Control panel Rear panel fasteners 6 Sensor chip Lead cable not shown is attache...

Page 6: ...In normal use dust can accumulate and can restrict airflow reducing performance and causing the unit to overheat See Disassembling the unit to clean coils and the heat exchange block below To maintai...

Page 7: ...o change without notice Some values may be approximate Fan speed varies automatically for optimized performance Warranty information is available at LegendBrandsRestoration com Be sure to visit Warran...

Page 8: ...enchufar la unidad tire siempre del enchufe nunca del cable Coloque el enchufe de tres clavijas que est en el extremo del cable de alimentaci n en un tomacorriente con descarga a tierra adecuado No us...

Page 9: ...para aumentar al m ximo la eficiencia de eliminaci n de agua de la unidad Coloque el deshumidificador sin obstrucciones lejos de cualquier objeto que pueda bloquear el flujo de aire que entra y sale...

Page 10: ...Desenrolle toda la manguera y coloque el extremo suelto en un fregadero desag e cubeta al aire libre o en cualquier lugar en que el agua pueda drenarse de forma segura Si utiliza una cubeta u otro re...

Page 11: ...configuraciones Presione PURGA para vaciar el tanque de condensado Presione ENCENDER APAGAR para encender la unidad Unidad ENCENDIDA Presione la tecla ENCENDER APAGAR para encender la unidad Barra sup...

Page 12: ...deje caer ni la aviente ni la coloque en un lugar en que pueda caerse Si maneja la unidad sin el debido cuidado sta puede da arse y causar alg n peligro o anular la garant a No exponga el panel de con...

Page 13: ...nel de control Tornillos de la placa de la base del panel posterior 5 no se muestran Tornillos del panel posterior x 6 Tornillos del panel posterior x 6 IMAGEN D DIAGRAMA DE LAS PIEZAS Tornillos de la...

Page 14: ...nspeccione el filtro reempl celo si observa que hay acumulaci n de polvo y suciedad AVISO Reemplace los filtros usados con un filtro nuevo Legend Brands 4 PRO n mero de pieza 100250 F581 paquete de 24...

Page 15: ...de agua seg n AHAM 80 F 27 C 60 de humedad relativa 130 pt 61 5 L por d a Eliminaci n de agua seg n grano bajo 80 F 27 C 20 de humedad relativa 17 pt 8 L por d a Cantidad m xima de aire procesado 325...

Page 16: ...doit tre mis la terre V rifier l tat du cordon d alimentation avant utilisation Ne pas l utiliser si le cordon est endommag Pour d brancher toujours saisir la prise et non le cordon Enfoncer les troi...

Page 17: ...ent tiquette et num ro de s rie du produit FIG C tiquette d avertissement tiquette de s rie et bouchon de vidange FIG A AVANT FIG B ARRI RE Prise du cordon Entr e d air humide Filtre 4 PRO Sortie d ai...

Page 18: ...a poign e d extension comme dispositif de fixation pour attacher l unit dans un v hicule pour le transport Une telle utilisation exerce une pression excessive sur les points d attache de la poign e da...

Page 19: ...re Heures de travail heure actuelle Affichage de l information Temp rature entr e sortie HR et GPP Retrait actuel GPP Barre de menu du bas GPP d entr e de r f rence rapide 1 60 GPP 2 60 90 GPP 3 90 GP...

Page 20: ...le d shumidificateur et causer un risque de danger ou annuler la garantie N exposez pas le panneau de commande l humidit la neige ou la pluie Entreposez et transportez l unit de mani re s re pour vit...

Page 21: ...rique Panneau de commande Boulons de la plaque d appui du panneau arri re 5 non montr s Boulons 6 du panneau arri re Boulons du panneau arri re 6 FIG D DIAGRAMME DES PI CES Boulons du bo tier x2 Empla...

Page 22: ...ttoyage pour serpentins solution de nettoyage pour bo tiers rotomoul s Avant chaque utilisation Regardez si le cordon de secteur est intact Aucune alt ration coupure etc Remplacez le cordon s il est e...

Page 23: ...CHNIQUE Mod le LGR 7000XLi 108110 AHAM de retrait d eau 26 6 C 80 F 60 HR 130 chopines 61 5 litres jour Retrait d eau Low Grain 26 6 C 80 F 20 HR 17 chopines 8 litres jour D placement de l air max 325...