background image

Odor Sensor

Negative Ions (NO OZONE)

Air Quality Sensor (PM2.5)

Remote Control

Ultra Quiet Sleep Mode

Multi Stage Filtration

U s e r   M a n u a l

UV Light

Intelligent All In One 

Summary of Contents for D950

Page 1: ...Odor Sensor Negative Ions NO OZONE Air Quality Sensor PM2 5 Remote Control Ultra Quiet Sleep Mode Multi Stage Filtration U ser Manual UV Light Intelligent All In One ...

Page 2: ...er Features Illustration of the Product Installation Instructions Function Descriptions Humidifier Functions Cleaning the Filter s Precautions Intelligent AirQualitySystem Troubleshooting Warranty 1 1 3 4 6 8 9 10 11 12 13 CONTENTS ...

Page 3: ...r Control Air Quality Sensor Humidity Indicator 1 The cold catalyst will play a catalyst effect in normal living environment without any external assistance like UV light sunlight high temperature or pressure 2 lt catalyzes the formaldehyde ammonia benzene TVOC hydrogen sulfide and other harmful gases to work with oxygen and then decompose them into water and carbon dioxide 3 The cold catalyst its...

Page 4: ...sesandsmoke The particles become denser and can be easily trapped by filters or sink to the ground The smaller the particle size the higher the capture rate Does not produce Ozone A variety of bacteria and airborne viruses can be killed by the 365nm ultraviolet light The UV germicidal lamp is used to purify the air and it is able to eliminate odor caused by smoke and mold Besides it also produces ...

Page 5: ...tlet Display Panel Middle Case Rear Case Remote Control Receiver Humiditity Sensor Water Tank Dumping Switch Air Quality Display Board Handle Control Button I L LU S T R AT I O N O F T H E P R O D U C T 15 1 6 11 2 7 12 3 8 13 4 9 14 5 10 15 12 13 4 3 14 1 2 5 6 11 10 9 8 7 ...

Page 6: ...s With your thumb against the front panel and your right hand in the gap at the front panel of the machine gently pull on the panel to open the front panel Make sure the filters are installed in position Turn the buckles to secure the filters Remove all packaging bags of filter 1 and filter 2 1 2 3 ...

Page 7: ...facing you Make sure the filters are installed in position Turn the buckles to secure the filters To install the front panel place the bottom part into the host buckle and close the front panel The front panel will be held by built in magnets Place Filter 1 Cold Catalyst and Activated Carbon Compound Filters back into the inner side of the product Note Ensure the tab side is facing you 1 3 4 2 ...

Page 8: ...st the use of perspective Product powered have a buzzer sounds The digital screen display the machine is in stand by mode 00 When pressing on the On Off button the tree design will flash in the digital screen When pressing on the timer button the machine is turned on and the intelligent odor sensor control is started too The machine will adjust the speed automatically according to the air quality ...

Page 9: ... odor sensor control is turned on automatically at the same time Press the sterilize button to turn on the UV germicidal light and the icon will be shown on the display screen When it is turned on The intelligent odor sensor control is turned on automatically at the same time Press the Mist button to turn on the humidifier Press the AUTO button the anion Germicide and wind speed and mist will turn...

Page 10: ...clockwise manner Please ensure that the rubber seal does not fall off Keep water tank inclined at 45 when installing it back into the machine After the installation of the water tank please ensure that no bubbles are generated before pressing the humidify button You can adjust the mist amount by pressing the mist button by low medium and high speed When the humidifier is not in use discharge the w...

Page 11: ...to release the harmful gas and odor at the same time to kill bacteria Use citric acid detergent and follow the instructions to configure solution pour into the humidifier and soak for 10 20 minutes then use the toothbrush or cloth to clean the humidifier discharge the water through the outlet and then rinse one more time Use the Brush Pen as cleaning tool brush tip enter from the airflow outlet on...

Page 12: ...o not allow children or the disabled to handle the equipment unsupervised 3 3 Before using the machine need to first check the power cord and plug are damaged do not bend or pull the power cord power cord and power cable do not arbitrarily change so as not to loose contact or an electric shock hazard 4 Do not use wet hand to plug power plug make sure the local power supply voltage is the same as i...

Page 13: ... a larger environment because it may create condensation water droplets within the product 15 Please use distilled purified or tap water for humidifier 16 Do not use any aroma or essential oils Intelligent Air Quality system memory reset instructions If the air quality indicator displays a red light and the machine power is cut off suddenly you may have to reset the intelligent memory sensor Other...

Page 14: ...e air quality is not significantly improved after long run of the machine Check the filter layers installation sequence Filters are worn out you need to replace all the filters When should I replace the filters The first filter The surface is dirty and fades in color The tiny hole of the cold catalyst is blocked by dust or the color of the active carbon has obviously changed Life time 8 14 months ...

Page 15: ...r six months whichever is greater This limited warranty does not apply to any defect resulting from accident misuse improper maintenance or normal wear and tear Your machine s proper functioning and lifetime are only guaranteed with the usage of DrevalAir filters Any defect resulting from the usage of non genuine DrevalAir filters or parts will not be covered by this warranty If you believe your p...

Reviews: