4th status byte (bit flags):
• 0 = Current limit
• 1 = Tube parameters near limit
• 2 = PROFIBUS error
• 3 = Low waterflow
• 4 = Excessive humidity
• 5 = Extended fault status
• 6 = Tube parameters exceeded limit
• 7 = CEX is locked (0 = Unlocked, 1 =
Locked)
163
report
tuning
control
Reports matching control when the
generator is connected to a Variomatch
unit through the matching interface. (For
more information on this interface, see
“Matching Interface” on page 4-2
.) This
command will not work with other
matching networks unless they are
electrically compatible and are connected
through the
Matching Interface
connector.
Returns one data byte:
• 0 = Manual control
• 1 = Automatic control
Set with command
13
.
0
1
Table 4-13. Host port commands (Continued)