4-56
Communication Interfaces
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
148
tube state
Reports the state of the tube.Send 1 data
byte (8-bit value) indicating the
parameter you want to read:
• 0 = Amount of time that tube was
heated
• 2 = tubes working parameters
Returns 4 data bytes.
If you sent a value of 0:
• Bytes 1 and 2 (16-bit value) =
Amount of time tube has been
heated, in hours
• Bytes 3 and 4 (16-bit value) = End of
tube life in hours
If you sent a value of 2:
• Bytes 1 and 2 (16-bit value) = Plate
voltage in volts
• Bytes 3 (8-bit value) = Plate current
in tenth of amperes
• Byte 4 (8-bit value) = Grid current in
tenth of amperes
1
4
151
report
ramping
rise and fall
times
Report on and off ramping rise and fall
times. The controller returns four data
bytes, least significant byte first:
• Bytes 1 and 2 represent rise time in
tenths of a second.
• Bytes 3 and 4 represent fall time in
tenths of a second.
Set with commands
31
and
32
.
0
4
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...