HPG 13150 400 V (A)
Communication Interfaces
4-49
HPG™ 13150 400 V RF Power Generator
Prerelease version
27
set pulsing
Sets the desired pulsing. Send one data
byte.
• 0 = Pulsing off
• 1 = Internal pulsing
• 2 = External pulsing
• 3 = External pulsing inverted
• 4 = Enable internal pulsing by
external pulsing input
See also commands
93
and
96
.
For more information, see
Pulsing Function” on page 5-37
.
Read back with command
177
.
1
1
(CSR only)
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes