HPG 13150 400 V (A)
Communication Interfaces
4-63
HPG™ 13150 400 V RF Power Generator
Prerelease version
187
report
frequency
tuning
parameters
Reports frequency tuning parameters.
The controller returns three bytes, least
significant byte first.
• Bytes1 and 2 return the maximum
frequency in kHz.
• Byte 3 returns the control mode for
frequency shift tuning (FST):
4
0 = No FST (frequency as defined
with command
18
)
4
1 = Integral, phase positive
4
2 = Integral, phase negative
4
3 = Proportional, phase positive
4
4 = Proportional, phase negative
Note:
This command is not available on
generators with fixed frequency.
Set with command
17
.
0
3
188
report
recipe step
set point/
run time
Reports the set point and run time for the
selected recipe step.
Send one byte to select the desired
recipe step.
The controller returns four data bytes:
• Bytes 1 and 2 represent the recipe
step set point in watts.
• Bytes 3 and 4 represent the recipe
step run time in tenths of seconds.
Set with commands
22
and
23
.
1
4
191
report
recipe step
ramp time
Reports the ramp time for the selected
recipe step. The controller returns two
data bytes:
• Bytes 1 and 2 represent the recipe
step ramp time in tenths of seconds.
Set with command
21
.
1
4
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...