Dresser Masoneilan 10000 Series Instruction Manual Download Page 12

www.dresser.com

Dresser Masoneilan 
Dresser, Inc., Flow Technologies 

10343 Sam Houston Park Drive 
Houston, Texas 77064 U.S.A 
T. +1-281-671-1640
F. +1-281-671-1735
E. [email protected]

DIRECT SALES OFFICE LOCATIONS

About Dresser Masoneilan

Dresser  Masoneilan,  headquartered  in  Houston,  Texas, 
has  been  the  leading  global  partner  in  process  control 
valves and solutions for more than 100 years. A business 
segment of Dresser, Inc., the company delivers customized 
products, services and diagnostic solutions for oil and gas, 
process and power generation applications. www.dresser.
com

© 2010 Dresser, Inc.  All rights reserved.

BELGIUM
Phone: 

+32-2-344-0970

Fax: 

+32-2-344-1123

BRAZIL
Phone: 

+55-11-2146-3600

Fax: 

+55-11-2146-3610

CANADA
Ontario
Phone: 

+905-335-3529

Fax: 

+905-336-7628

CHINA
Phone: 

+86-10-8486-4515

Fax: 

+86-10-8486-5305

FRANCE
Courbevoie
Phone: 

+33-1-4904-9000

Fax: 

+33-1-4904-9010

GERMANY
Viersen
Phone: 

+49-2162-8170-0

Fax: 

+49-2162-8170-280

INDIA
Mumbai
Phone: 

+91-22-8354790

Fax: 

+91-22-8354791

New Delhi
Phone: 

+91-11-2-6164175

Fax: 

+91-11-5-1659635

ITALY
Phone: 

+39-081-7892-111

Fax: 

+39-081-7892-208

JAPAN
Chiba 
Phone: 

+81-43-297-9222

Fax: 

+81-43-299-1115

KOREA
Phone: 

+82-2-2274-0748

Fax: 

+82-2-2274-0794

MALAYSIA
Phone: 

+60-3-2161-0322

Fax: 

+60-3-2163-6312

MEXICO
Phone:  

+52-5-310-9863

Fax:  

+52-5-310-5584

THE NETHERLANDS
Phone: 

+31-15-3808666

Fax: 

+31-18-1641438

RUSSIA
Veliky Novgorod
Phone: 

+7-8162-55-7898

Fax: 

+7-8162-55-7921

Moscow
Phone: 

+7 495-585-1276

Fax: 

+7 495-585-1279

SAUDI ARABIA
Phone: 

+966-3-341-0278

Fax: 

+966-3-341-7624

SINGAPORE
Phone: 

+65-6861-6100

Fax: 

+65-6861-7172

SOUTH AFRICA
Phone: 

+27-11-452-1550

Fax: 

+27-11-452-6542

SOUTH & CENTRAL 

AMERICA AND THE CARIBBEAN
Phone: 

 +55-12-2134-1201

Fax:    

 +55-12-2134-1238

SPAIN
Phone: 

+34-93-652-6430

Fax: 

+34-93-652-6444

UNITED ARAB EMIRATES
Phone: 

+971-4-8139-200

Fax: 

+971-4-8838-038

UNITED KINGDOM
Wooburn Green
Phone: 

+44-1628-536300

Fax: 

+44-1628-536319

UNITED STATES
Massachusetts
Phone: 

+1-508-586-4600

Fax:  

+1-508-427-8971

Corpus Christi, Texas 
Phone: 

+1-361-881-8182

Fax: 

+1-361-881-8246

Dresser Direct
Deer Park, Texas
Phone: 

+1-281-884-1000

Fax: 

+1-281-884-1010

Dresser Flow Technologies
Houston, Texas
Phone: 

+1-281-671-1640

Fax: 

+1-281-671-1735

California
Phone: 

+1-562-941-7610

Fax: 

+1-562-941-7810

EH10000 06/10

About Dresser, Inc.

Dresser  Inc.  is  a  global  leader  in  providing  highly- 
engineered  infrastructure  products  for  the  global  energy 
industry. Leading brand names within the Dresser portfolio 
include Dresser Wayne® retail fueling systems, Waukesha® 
natural  gas-fired  engines,  Masoneilan®  control  valves, 
Consolidated® pressure relief valves, and ROOTS® blowers 
and  rotary  gas  meters.  The  company  has  manufacturing 
and  customer  service  facilities  strategically  located 
worldwide and a sales presence in more than 150 countries.  
www.dresser.com

Summary of Contents for Masoneilan 10000 Series

Page 1: ...Instruction Manual EH10000 06 10 10000 Series Double Ported Globe Valves Putting You In Control ...

Page 2: ... 3 Installation 2 4 Air Piping 2 5 Body Disassembly Refer to Figure 9 3 6 Maintenance Repair 3 6 1 Seat Ring Removal 3 6 2 Bushing Removal 3 6 3 Lapping Seats 3 6 4 Plug Stem Pinning 4 6 5 Packing Box 5 6 6 Packing Box Optional Lubrication Figure 7 5 7 Valve Body Reassembly 6 Based on general field failure data and product design analysis a useful life period of 25 years or longer can be expected ...

Page 3: ... subject to change without prior notice The information contained in this manual in whole or part shall not be transcribed or copied without Masoneilan s written permission Please report any errors or questions about the information in this manual to your local supplier These instructions are written specifically for the 10000 Series Control Valve and do not apply for other valves outside of this ...

Page 4: ...hat the larger of the two V notches in the plug is oriented to face the inlet of the valve 3 1 Before installing the valve in the line clean piping and valve of all foreign materials such as welding chips scale oil grease or dirt Gasket surfaces should be thoroughly cleaned to ensure leak proof joints 3 2 To allow for in line inspection maintenance and removal of the valve without service interrup...

Page 5: ...n should be read and understood before proceeding 6 1 Seat Ring Removal Threaded seat rings 15 and 16 are installed tightly at the point of manufacture and after years of service they are often difficult to remove To facilitate removal seat ring wrenches can be fabricated to engage the seat ring lugs and adapted to a shock wrench see Figure 3 If the ring is exceptionally resistant to removal the a...

Page 6: ...dy until it is seated G Place bonnet 6 on the body and using body stud nuts 12 spaced equally apart fasten to the body using only slight pressure and tighten evenly Do not tighten nuts to torque specifications at this time The bonnet is used temporarily for guiding purposes H Insert two or three pieces of packing 17 into the packing box to assist in guiding the stem and plug during lapping I Screw...

Page 7: ...his could prevent smooth operations of the valve If all compression is used up and the valve leaks new packing is required Valve must be isolated and pressure vented before performing packing box maintenance Proceed as follows A Loosen and remove packing flange nuts 2 B Raise packing flange 3 and packing follower 19 up the valve stem C Remove packing 17 Note Only the top pieces of the old packing ...

Page 8: ...es in that plug is in line with the inlet of the valve Placement of a witness mark on the stem may be helpful E Install bonnet gasket 13 bonnet 6 and loosely install body stud nuts 11 Note For ease of accessibility the bonnet should be positioned so that the packing flange studs are at right angles to the flow center line Refer to Figure 10 for proper bolt torque and tightening sequence specificat...

Page 9: ...Instructions EH10000 06 10 10000 Series Double Ported Globe Valves 7 Figure 9 Note V Port is shown 90 out of position It must be installed as explained in Section 3 Figure 10 ...

Page 10: ...Instructions EH10000 06 10 10000 Series Double Ported Globe Valves 8 Notes ...

Page 11: ...Instructions EH10000 06 10 10000 Series Double Ported Globe Valves 9 Notes ...

Page 12: ...0 5584 THE NETHERLANDS Phone 31 15 3808666 Fax 31 18 1641438 RUSSIA Veliky Novgorod Phone 7 8162 55 7898 Fax 7 8162 55 7921 Moscow Phone 7 495 585 1276 Fax 7 495 585 1279 SAUDI ARABIA Phone 966 3 341 0278 Fax 966 3 341 7624 SINGAPORE Phone 65 6861 6100 Fax 65 6861 7172 SOUTH AFRICA Phone 27 11 452 1550 Fax 27 11 452 6542 SOUTH CENTRAL AMERICA AND THE CARIBBEAN Phone 55 12 2134 1201 Fax 55 12 2134 ...

Reviews: