Install the bottom set of screws and nuts as shown
in Figure 32.
After all three sets of screws and nuts are installed,
tighten each set.
Figure 32: Lower screws and nuts installed
After all hardware is tightened, install the red
tamper seals (supplied) on the Endpoint Module as
shown in Figure 33.
Figure 33: Attach top AMR mounting bracket
screws
9
Pulse Output Connections
This section provides information about connecting the pulse outputs with the meter and configuring
them with the Dresser MeterWare software.
Each Dresser Series D meter comes standard with two (2) flow frequency pulse outputs (Pulse Outputs 1
and 2) that represent volumetric information for remote data collection. Pulse Outputs 1 and 2 can be
configured for faults and alarm signals. Pulse Output 3 is reserved for fault and alarm signals only.
The pulse output cable is routed through a cable gland located at the back of the meter. The output
location is recessed and covered by a protective plate as shown in Figure 34.
Figure 34: Pulse output cable under the protective plate