![DRENO ALPHA-V 5 M Manual Download Page 28](http://html.mh-extra.com/html/dreno/alpha-v-5-m/alpha-v-5-m_manual_2530843028.webp)
- 28
13. Tools
The tools necessary for a normal maintenance of the electropumps are the following:
• Allen screw keys of : 4, 5 and 6 mm
• Cross screwdriver
• 2 screwdrivers
• Hexagonal keys of: 8 and 17 mm
14. Troubles and remedies
The pump does not start:
•
Loss of electric power supply (check if the fusibles have broken or a protection relay of the circuit intervented);
•
The selection switch is turned OFF (turn ON);
•
Loss of phase (check the connection);
•
The impeller is blocked;
•
Mechanical seal or ball bearing seized.
The pump does not stop:
•
Failure to the stop regulator (clean or replace the stop regulator).
•
The pump is not able to empty the tank till the stop level: there may be leaks in the installation; absence of
the non return ball valve, to avoid the liquid relow; necessity to replace the pump with another one of bigger
capacity.
The pump works, but the delivery is scarce or inexistent:
• The pump works with a wrong rotating direction (this is possible only with threephase motors);
• Check the wear conditions of the hydraulic part, if necessary replace the parts;
• The pump is closed by an air-pocket (switch of the electropump and restart it after few minutes);
• The delivery pipe is obstructed, the non return ball- valves or the sluicegates are in part closed.