Rev. 1.2.
12
Performance
z
The control uses a blue color back light liquid crystal display with white back light
induction type touching key.
z
Turning the steam on will fill the generator with water automatically, when system is
shut-down an automatic water draining system turn on.
z
Includes steam and light and fan control functions.
z
Steam temperature regulation range: Centigrade temperature 30~60C, Fahrenheit
86~140F; Steam time regulation range: 0~60 minutes.
z
Automatic temperature controls also include tracking of excess temperature, over
pressure and power leakage protection function.
Operation Instructions:
Switch-on: Push the power switch, the present cabin temperature is shown on the
display, the top light turns on, and the system stays in the state of readiness.
Steam: Push the steam key directly to turn steam function on or off.
Temperature-set: Push temperature setting key, ambient temperature is shown on
the screen. Push the “tempe” or “temperature –“key to get the wanted steam
temperature. The temperature will gradually increase or decrease within 30 ~ 6
0℃.
“Celsius” displays the Celsius temperature; “Fahrenheit” displays Fahrenheit
temperature. If the ambient temperature in the cabin is higher than that set by the
steam bath temperature, the steam generator can not be started.
Time-set: Push the time setting key and the steam generator and control go into the
time-set state; and push the “time +” or “time –“key to get desired time of the steam
bath. The time range is 5~60 minutes.
Lighting: Push the light key, and the light and the fan can be switched on or off.
Switch-off: Push the power key and switch off all the functions.
If not using steam options/control for a long time – we suggest that you switch off
the main electric power of the units
Warnings
Do not connect this steam shower with other electric appliances not recommended by
DreamLine™, and do not take apart the hermetically sealed lines or the electric lines
from the power box.
A drainage pipeline shall be fixed to auto-drain valve of the main steam generator,
and it’s better to add a water filter before the water entrance to increase generator’s
service life.
The steam generator should be working with water hardness levels 60-120 mg/l. If
hardness of your water more than recommended it can cause “scale” (mineral build
up in pipes and plumbing fixtures). Scale can cause of your steam unit damage. You
need to treat your water. Water softeners are the most frequently used of all water-
conditioning devices and are installed for reducing hardness for private wells and
utility supply with high levels of calcium or magnesium.
The line from the power box shall be plugged according to the digit capacity and the
size. Do not short circuit.
The steam generator is complicated option and shall be installed by the qualified and
authorized technical persons.
DreamLine™ shall not be responsible for negative consequences due to any
incorrect installation or improper operations per instructions listed above.