 OPERATION AND FITTING INSTRUCTIONS 

2.1

 

OPERATING CONDITIONS 

 

The tank shall only be used in accordance with the conditions specified on the power plate 

and  in  instructions  for  electric  wiring.

  

Besides  legally  acknowledged  national  regulations 

and standards, also conditions for connection defined in local electric and water works have 

to be adhered to, as well as the installation and operation manual.

 

The room, in which the 

appliance  will  be  operated,  must  be  frost

-

free.

 

The  appliance  has  to  be  mounted  at  a 

convenient  place,  it  means  that  the  appliance  must  be  easily  available  for  potential 

necessary maintenance, repair or replacement, as the case may be.

  

We emphasize that the tank shall not be connected to power supply if flammable liquids 

(benzine, stain cleaner) or gases, etc., are handled in its proximity.

 

 

If water is strongly calcareous we recommend that any of the common decalcifying devices 

was installed with the appliance, or that the thermostat was set to the minimum operating 

temperature  of  60

o

C.

 

For  proper  operation,  drinkable  water  of  adequate  quality  shall  be 

used.

 

To avoid potential deposits we recommend that water filter is connected in series with 

the tank.

 

 

2.2

 

PLUMBING FIXTURE

 

 

Tanks are connected to plumbing fixtures as shown in Figure 5.

 

For potential disconnection 

of the tank, utility water inlets and outlets must be provided with Js 3/4“ screw coupling.

 

If 

the hot utility water (HSW) distribution is equipped with circulation circuit, the reverse pipe 

is connected to the inlet identified as CIRCULATION.

 

The 100, 125, 160 NTR and 100, 125 

NTR / HV types are equipped with a discharge outlet.

 

The tank shall be equipped with safety 

valve  to  ensure  operation.

 

The  safety  valve  is  mounted  on  the  cold  water  inlet  identified 

with a blue ring.

 

 

Every hot utility water pressure tank shall be equipped with membrane spring loaded with 

safety valve.

 

Safety valve shall be easily accessible, fitted as close as possible to the tank.

 

Supply piping shall have minimum inside diameter identical with that of safety valve.

 

Safety 

valve  is  placed  high  enough  to  secure  dripping  water  drain  by  gravity.

 

We  recommend 

mounting  the  safety  valve  onto  a  branch  pipe.

 

Easier  exchange  without  the  necessity  of 

draining  water  from  the  tank.

 

Safety  valves  with  fixed  pressure  settings  from  the 

manufacturer are used for the assembly.

 

The starting pressure of the safety valve must be 

identical to the maximum allowed pressure of the tank, and at least 20 % higher than is the 

maximum  pressure  in  the  water  main  (Table  2).

 

If  the  water  main  pressure  exceeds  such 

value, a reduction valve must be added to the system.

 

No closing armature may be mounted 

between the tank and the safety valve.

 

During assembly, follow the guide provided by the 

safety equipment manufacturer.

 

Summary of Contents for OKH 100 NTR

Page 1: ...INDIRECT HOT WATER TANKS OKH 100 NTR HV OKH 100 NTR OKH 125 NTR HV OKH 125 NTR OKH 160 NTR Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou Phone 420 326 370 990 Fax 420...

Page 2: ...ICAL INSTALLATION 11 2 3 2 ELECTRONIC THERMOSTAT WIRING METHODS 11 2 4 CONNECTION OF INDIRECT TANK TO HOT WATER SYSTEM 12 2 5 FIRST COMMISSIONING 13 2 6 PUTTING OUT OF SERVICE DISCHARGE 13 2 7 INSPECT...

Page 3: ...like to thank you for your decision to use a product of our brand The present instructions will introduce you to the use construction maintenance and other information regarding electrical water tank...

Page 4: ...ts of users 1 2 2 ENERGY SAVING Hot utility water reservoir is insulated by means of top quality polyurethane foam with zero CFCs content Set the temperature on the tank thermostat to that you need fo...

Page 5: ...and the flange Thermowells for thermostat sensors and thermometer installation are placed in the flange lid An anode rod is mounted onto the M8 nut The water reservoir is insulated by means of polyure...

Page 6: ...OKH 160 NTR Figure 3 neck 1 1 outer neck 2 3 4 inner neck 3 3 4 outer neck 4 1 2 inner A mm B mm C mm D mm E mm F mm L mm OKH 100 NTR 885 882 129 520 182 622 522 OKH 125 NTR 1050 1047 129 520 182 752...

Page 7: ...Figure 4 neck 1 3 4 outer neck 2 3 4 outer neck 3 3 4 outer neck 4 3 4 outer neck 5 3 4 outer neck 6 1 2 inner A mm B mm C mm D mm E mm F mm G mm OKH 100 NTR HV 885 882 127 520 165 119 182 OKH 125 NTR...

Page 8: ...RE OF THE RECEPTACLE MPa 0 6 MAXIMUM PRESSURE OF THE EXCHANGER MPa 1 MAXIMUM HSW TEMPERATURE C 80 RECOMMENDED HSW TEMPERATURE C 60 HSW CONNECTION G HEATING WATER CONNECTION G 1 G 1 G 1 G G ELECTRICAL...

Page 9: ...l disconnection of the tank utility water inlets and outlets must be provided with Js 3 4 screw coupling If the hot utility water HSW distribution is equipped with circulation circuit the reverse pipe...

Page 10: ...First of all close water inlet in the tank Find necessary pressure values in the following table For proper safety valve operation a backflow valve shall be mounted on the inlet pipes preventing spont...

Page 11: ...50 Hz Elastic cable CYSY 4Cx0 75 can be used for cross connection Connecting terminals are identified on the tank s terminal board 2 3 2 ELECTRONIC THERMOSTAT WIRING METHODS Wiring of tanks of the be...

Page 12: ...flush the heating circuit before the assembly All wiring connections must be properly insulated from heat If the system works with priority heating of HSW using a three way valve always follow the ins...

Page 13: ...nd that the flange lid bolts are fastened 6 Screw down the electric installation guard 7 When heating utility water with heat energy from the hot water heating system open the heating water inlet and...

Page 14: ...s of heated water its temperature and on the volume of hot water used We recommend checking and cleaning the tank from lime scale and eventual replacement of the anode rod after two years of operation...

Page 15: ...input pressure defective safety valve Table 3 Do not attempt to repair the failure yourselves Seek either expert or service help It does not take much for an expert to remove the defect When organizi...

Page 16: ...ure may be mounted between the tank and the safety valve If the overpressure in the eater main exceeds 0 6 MPa a reduction valve must be mounted before the safety valve All outlets of hot water must b...

Page 17: ...our own interest to check the completeness of the accessories 4 3 DISPOSAL OF PACKAGING MATERIAL AND NON FUNCTIONING PRODUCT A service fee for providing return and recovery of packaging material has b...

Reviews: