Drayton MiStat P710R Installation Manual Download Page 2

MiStat

MiStat

Technical Data

Step 5:

 Installer Settings

Step 5:

 Installer Settings (continued)

Feature:

Description:

  Factory Pre-Set:

Installer settings

CAUTION! 

 These settings should only be set-up by a qualifi ed person. They can infl uence safety and the 

proper functioning of the system.

Zone settings

Customise the MiStat according to personal requirements

Rename zone

To rename an existing zone

Heating

Minimum temp

It will not be possible to set a lower temperature

5°C

Maximum temp

It will not be possible to set a higher temperature

30°C

Backlight

Available options are:  On with timeout,  Always Off

On with timeout

Powersave

To reduce power use when not being adjusted. Available options are: Partial 

display with key data, no display until button press.

Partial display

Temp. offset

Adjust the displayed temperature to personal needs

0.0°C

Screen lock

Enable or disable the lock in the room unit. 

To Lock: Enter a 3 digit code for protection

To Unlock: Enter the 3 digit code

Disabled

Master Code 401

RF binding

Bind the remote thermostat to the receiver.

Pre-bound

System settings

Customise the MiStat according to system requirements

Control type

Select TPI, TP or On/Off

TPI

Cycle rate (only when 

Control type is TPI or TP)

Select 6 (Gas) cph (cycles per hour), 12 (Electric) cph or 3 (Oil) cph

6 cph

Min on/off (only when 

Control type is On/off)

Select 1 to 30 minutes (The minimum duration for the relay to be On or Off)

5 min.

Hysteresis (only when 

Control type is On/off)

Select Off, 0.1 to 5° (Off = No temperature hysteresis, even on very low temp. 

changes, the relay will switch over according to Min On/Off time)

0.5°C

Frost protection

Enable or disable the Frost protection in the MiStat unit. (Temperature = 5°C)

Disabled

Valve protection

The output will be activated for the specifi ed time (in minutes). This will happen 

weekly, related to the last actuation of the output.  Select 0 to 10 minutes.

0 minutes (Off)

Optimum/Delayed start

Available options are:  Off,  Optimum, Delayed

Off

System reset

Will reset all settings to factory pre-sets

View product information

View the product details, e.g. Part number, Firmware revision etc.

Signal strength

Informs about the current signal strength, see step 3.

Service settings

To help comply with regulation 36 of the Gas safety [Installation & Use] regulations 1998. On expiry of 

the warning period, the alarm sounds, starting at midday and continuing until a button is pressed. This is 

repeated daily until the service function is reset.   To enter these settings a code is requested.

Si status

Enable or disable Service mode

Disabled

Si type

Select between, Reduced comfort, Switched off & No effect (warnings only)

Reduced Comfort

Reduced comfort duration

Set the duration for the reduced comfort setting (0 to 60mins.)

15 min.

Si due date

Set the date the next boiler service is due

Today

Warning start

Set the number of days for the on-screen service due warning (0 to 60 days)

30 days

Boost status

Enable or disable Service Boost

Disabled

No. of boosts

Set the number of Boosts to be available after service is due (1 to 99)

10

Audible alarm

Enable or disable Service Alarm

Enabled

Installer tel.

Enter the Installer telephone number if required

Set password

Set password to restrict access to the Service settings

0000

Step 6:

 Commissioning

Note:

 Only needed if not already bound, ie if 

replacing either the MiStat thermostat or the 
MiStat receiver.

1. 

Turn on power for the receiver. The red LED will
come on. 

If LED is green or Off, the device is already 
bound, no further action needed here 

(If a

separate programmer/Timer is fi tted, ensure 
that it is switched on)

2. 

Push the button for >5 Seconds and the LED 
will fl ash red – yellow – green --- -red – yellow -
green… 

3. 

Enter binding mode on the corresponding 
MiStat room unit, see Step 5: Installer settings

Important:

 It is essential, that the binding is

carried out between the corresponding room 
unit and the receiver

4. 

The possible results are as follows;

1.

 Bind OK’ will be indicated on the MiStat

room unit if binding was successful. 
After a few seconds the Signal strength will be 
indicated on both the MiStat room unit and the
MiStat receiver, see below. 

2

. ‘

 Bind Failed’ will be displayed if

unsuccessful.

3.

 If ‘Poor’ signal is displayed, look for a better

location. 

4.

 If ‘No Signal’ is displayed, try connecting

again with the room unit in a different position.

MiStat Room Unit

MiStat Receiver

Immediately after binding, these signals will indicate 
the signal quality for 1 minute.
• 

three green fl ashes = Very good signal

• 

double amber fl ashes = Good signal

• 

single red fl ashes = Poor signal

• 

steady red = No signal

To check the wireless connection 

A green LED on the receiver will indicate a good RF 
connection.

From the Home screen, select 

Settings

, then 

Installer settings

 

as shown.

From here you can edit the 
assigned zones, rename them if 
required and adjust the Service 
settings.

If using the Service feature, 
remember to set the 

Password

 

when complete.

Step 4:

 Mounting Options

Once the best position has been identifi ed, the MiStat 
should be fi xed to the wall using the wall bracket as 
shown.

Care should be taken to mount the thermostat in a
position which is not subject to direct sunlight or 
draughts. Preferably it should be mounted on an inside 
wall about 1.2m (4ft) above the fl oor in a position where 
it can respond to room temperature but away from the 
direct infl uence of radiators or other appliances giving 
off heat.

NB. MiStat can also be positioned using the table 
stand included.

MiStat

MiStat

It has to be placed in a location where it will be able to 
control the room temperature.

 

Installer Notes:

Customise the controller according to application 
requirements (from installer only)

MiStat P721R & MiStat R111M

Supply voltage 

MiStat P: 2 x AA 1,5V alkaline 
batteries
MiStat R: 230V

Switch rating 

MiStat R: 2(1)A 230V a.c.

Ambient 
temperature 

Operating: 0°C to 45°C;  
Storage: –20°C to 55°C;

Battery life

MiStat P: 2 years (typically)

Temperature 
range

5°C to 30°C

Temperature 
resolution

0.5 °C, display and setting

Control accuracy

<0.6°C at 4°/hour

Wiring

MiStat R: Fixed wiring only, to comply 
with current IEE regulations (BS7671)
MiStat P: No wiring required

Mounting

MiStat R: Industry standard wallplate
MiStat P: Wall bracket or table stand

Radio frequency

868.3MHz (Bi-directional 
communication)

Radio signal range

30m typically.  The range may be 
affected by the composition / density 
and number of walls between the 
MiStat P and MiStat R

Pollution degree

2

Software class

A

Rated impulse 
voltage

MiStat R: 2.5kV

Ball pressure test 
temperature

MiStat R: 75°C

Energy Class

IV = 2%  (According to EU 811/2013, 
812/2013, 813/2013, 814/2013)

Relevant EC 
Directives:

2006/95/EC Low Voltage Directive 
2004/108/EC Electromagnetic 
Compatibility Directive
1995/5/EC R&TTE Directive
2006/66/EC Battery Directive
2011/65/EU RoHS Directive

Applied 
Standards:

EN60730-1; EN60730-2-7; EN60730-2-9
ETSI EN 300 220-3; ETSI EN 301 489-3

User Code:

 

1.2m

Client

Invensys

File Name

7378 Drayton Instruction Manual Update 06490189001

Artworker

-

Proof Stage

PRINT

Finished Size

280x297mm

Creative Director

Mike Lane

Artwork %

100%

Modification Date

20/04/15 11:59AM

Bleed

3mm

Reviews: