MiStat
MiStat
Technical Data
Step 5:
Installer Settings
Step 5:
Installer Settings (continued)
Feature:
Description:
Factory Pre-Set:
Installer settings
!
CAUTION!
These settings should only be set-up by a qualifi ed person. They can infl uence safety and the
proper functioning of the system.
Zone settings
Customise the MiStat according to personal requirements
Rename zone
To rename an existing zone
Heating
Minimum temp
It will not be possible to set a lower temperature
5°C
Maximum temp
It will not be possible to set a higher temperature
30°C
Backlight
Available options are: On with timeout, Always Off
On with timeout
Powersave
To reduce power use when not being adjusted. Available options are: Partial
display with key data, no display until button press.
Partial display
Temp. offset
Adjust the displayed temperature to personal needs
0.0°C
Screen lock
Enable or disable the lock in the room unit.
To Lock: Enter a 3 digit code for protection
To Unlock: Enter the 3 digit code
Disabled
Master Code 401
RF binding
Bind the remote thermostat to the receiver.
Pre-bound
System settings
Customise the MiStat according to system requirements
Control type
Select TPI, TP or On/Off
TPI
Cycle rate (only when
Control type is TPI or TP)
Select 6 (Gas) cph (cycles per hour), 12 (Electric) cph or 3 (Oil) cph
6 cph
Min on/off (only when
Control type is On/off)
Select 1 to 30 minutes (The minimum duration for the relay to be On or Off)
5 min.
Hysteresis (only when
Control type is On/off)
Select Off, 0.1 to 5° (Off = No temperature hysteresis, even on very low temp.
changes, the relay will switch over according to Min On/Off time)
0.5°C
Frost protection
Enable or disable the Frost protection in the MiStat unit. (Temperature = 5°C)
Disabled
Valve protection
The output will be activated for the specifi ed time (in minutes). This will happen
weekly, related to the last actuation of the output. Select 0 to 10 minutes.
0 minutes (Off)
Optimum/Delayed start
Available options are: Off, Optimum, Delayed
Off
System reset
Will reset all settings to factory pre-sets
View product information
View the product details, e.g. Part number, Firmware revision etc.
Signal strength
Informs about the current signal strength, see step 3.
Service settings
To help comply with regulation 36 of the Gas safety [Installation & Use] regulations 1998. On expiry of
the warning period, the alarm sounds, starting at midday and continuing until a button is pressed. This is
repeated daily until the service function is reset. To enter these settings a code is requested.
Si status
Enable or disable Service mode
Disabled
Si type
Select between, Reduced comfort, Switched off & No effect (warnings only)
Reduced Comfort
Reduced comfort duration
Set the duration for the reduced comfort setting (0 to 60mins.)
15 min.
Si due date
Set the date the next boiler service is due
Today
Warning start
Set the number of days for the on-screen service due warning (0 to 60 days)
30 days
Boost status
Enable or disable Service Boost
Disabled
No. of boosts
Set the number of Boosts to be available after service is due (1 to 99)
10
Audible alarm
Enable or disable Service Alarm
Enabled
Installer tel.
Enter the Installer telephone number if required
Set password
Set password to restrict access to the Service settings
0000
Step 6:
Commissioning
Note:
Only needed if not already bound, ie if
replacing either the MiStat thermostat or the
MiStat receiver.
1.
Turn on power for the receiver. The red LED will
come on.
If LED is green or Off, the device is already
bound, no further action needed here
(If a
separate programmer/Timer is fi tted, ensure
that it is switched on)
2.
Push the button for >5 Seconds and the LED
will fl ash red – yellow – green --- -red – yellow -
green…
3.
Enter binding mode on the corresponding
MiStat room unit, see Step 5: Installer settings
Important:
It is essential, that the binding is
carried out between the corresponding room
unit and the receiver
4.
The possible results are as follows;
1.
‘
Bind OK’ will be indicated on the MiStat
room unit if binding was successful.
After a few seconds the Signal strength will be
indicated on both the MiStat room unit and the
MiStat receiver, see below.
2
. ‘
Bind Failed’ will be displayed if
unsuccessful.
3.
If ‘Poor’ signal is displayed, look for a better
location.
4.
If ‘No Signal’ is displayed, try connecting
again with the room unit in a different position.
MiStat Room Unit
MiStat Receiver
Immediately after binding, these signals will indicate
the signal quality for 1 minute.
•
three green fl ashes = Very good signal
•
double amber fl ashes = Good signal
•
single red fl ashes = Poor signal
•
steady red = No signal
To check the wireless connection
A green LED on the receiver will indicate a good RF
connection.
From the Home screen, select
Settings
, then
Installer settings
as shown.
From here you can edit the
assigned zones, rename them if
required and adjust the Service
settings.
If using the Service feature,
remember to set the
Password
when complete.
Step 4:
Mounting Options
Once the best position has been identifi ed, the MiStat
should be fi xed to the wall using the wall bracket as
shown.
Care should be taken to mount the thermostat in a
position which is not subject to direct sunlight or
draughts. Preferably it should be mounted on an inside
wall about 1.2m (4ft) above the fl oor in a position where
it can respond to room temperature but away from the
direct infl uence of radiators or other appliances giving
off heat.
NB. MiStat can also be positioned using the table
stand included.
MiStat
MiStat
It has to be placed in a location where it will be able to
control the room temperature.
Installer Notes:
Customise the controller according to application
requirements (from installer only)
MiStat P721R & MiStat R111M
Supply voltage
MiStat P: 2 x AA 1,5V alkaline
batteries
MiStat R: 230V
Switch rating
MiStat R: 2(1)A 230V a.c.
Ambient
temperature
Operating: 0°C to 45°C;
Storage: –20°C to 55°C;
Battery life
MiStat P: 2 years (typically)
Temperature
range
5°C to 30°C
Temperature
resolution
0.5 °C, display and setting
Control accuracy
<0.6°C at 4°/hour
Wiring
MiStat R: Fixed wiring only, to comply
with current IEE regulations (BS7671)
MiStat P: No wiring required
Mounting
MiStat R: Industry standard wallplate
MiStat P: Wall bracket or table stand
Radio frequency
868.3MHz (Bi-directional
communication)
Radio signal range
30m typically. The range may be
affected by the composition / density
and number of walls between the
MiStat P and MiStat R
Pollution degree
2
Software class
A
Rated impulse
voltage
MiStat R: 2.5kV
Ball pressure test
temperature
MiStat R: 75°C
Energy Class
IV = 2% (According to EU 811/2013,
812/2013, 813/2013, 814/2013)
Relevant EC
Directives:
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic
Compatibility Directive
1995/5/EC R&TTE Directive
2006/66/EC Battery Directive
2011/65/EU RoHS Directive
Applied
Standards:
EN60730-1; EN60730-2-7; EN60730-2-9
ETSI EN 300 220-3; ETSI EN 301 489-3
User Code:
1.2m
Client
Invensys
File Name
7378 Drayton Instruction Manual Update 06490189001
Artworker
-
Proof Stage
Finished Size
280x297mm
Creative Director
Mike Lane
Artwork %
100%
Modification Date
20/04/15 11:59AM
Bleed
3mm