Drayton MiStat C C110C Homeowner'S Manual Download Page 2

ID

Feature:

Description:

Factory Pre-Set:

5

BACKLIGHT

Available options are:  On with timeout (TIMED),  Always Off (OFF)

TIMED

7

LOCK

Protect MiStat against unauthorised use. If active, any key press will show LOCKED for a few Secs.
To lock: Enter your 3 digit code for protection.
To unlock: Press +&- key for approx. 5 sec. Enter your 3 digit code

000
Master code 401

10

VALV-PROT

The output will be activated for the specified time (in Minutes). This will happen weekly, related to 
the last actuation of the output. Select OFF, 1 to 10 Minutes.

OFF

11

WIRELESS

To create a radio link with the receiver or to view the RF signal quality

Pre-bound

12

BIND

Press 

( )

 key to start connecting to the receiver.

NB. “binding” must also be activated on the receiver, see Step 6 Commissioning

BINDING

An RF connection to the receiver will be created. If successful, the SIGNAL level will be displayed. 
If unsuccessful, FAILED will be displayed.

13

SIG-LEVEL

Indicates the quality of the RF transmission 
VERY GOOD, GOOD, POOR, NO SIGNAL

DONE

To exit WIRELESS sub menu  

15

PROD-INFO

View the product details, e.g. Part number, Firmware revision etc. Use 

( )

 key to show the details

16

RESET

Will reset all settings to factory pre-sets 

OFF

DONE

Exit from the settings menu to INST-S

 

INSTALLATION

 Guide

Step 3:

 Signal Strength

The MiStat Cylinder thermostat is prebound to the MiStat 
receiver in the factory so they just need to be positioned 
in the best place for wireless communication. To help 
with this there is a built in Signal strength indicator, 
available in the Installer settings menu on the MiStat 
thermostat, as shown. 

It is recommended that the signal strength is Good 
or Very Good to ensure ongoing communication is 
maintained. 

To enter signal strength menu

 (see step 5 for more detail)

•  Press + & - for approx. 5 secs, then scroll (+/-) to show 

INST-S, 

• press 

( )

 to enter the installer menu, 

• Press +/- until 11 WIRELESS is shown,
• press 

( )

 to enter, 

• press +/- to show 13 SIG-LEVEL as shown, 
• press 

( )

 to see the current signal strength.

Step 4 

(Continued)

Step 5:

 Installer Settings

Customize the MiStat according to application needs.

Step 1:

 Mounting the Wallplate

Step 2:

 Wiring

IMPORTANT:

Installation must only be carried out by a 
qualified electrician or heating engineer.

Make sure mains input has a 3 amp fuse.

CAUTION! Before installation, make sure the 

mains supply is switched off!

Option 2: Using an existing wall-plate

Loosen the securing screws on the old receiver 
and unplug it.  Check that there’s 20mm clearance 
to the right of the wall-plate and 25mm above it.  
Check the wiring diagram for your product model 
to compare terminals and, if necessary, change 
the wiring of the wall-plate to suit.  Now plug the 
MiStat R unit into the wall-plate and tighten the 
securing screws.

Check the 3A fuse, and switch on the mains.

Option 1: Fitting a new wall-plate

The ideal location is close to the boiler or central 
heating system.  For the best performance install 
in an open space, at least 30cm distance from 
any metal objects including wall boxes and the 
boiler housing.  It is recommended that the 
MiStat R is mounted on the wall nearest the final 
location of the MiStat C room unit and not less 
than 30cm from the boiler side panel. 

Loosen the securing screws, remove the 
wallplate and, if surface wiring is to be used, 
snap out the cable entry strip on the bottom 
edge of the wallplate with a pair of pliers.  Fix the 
wallplate, terminals at the top, either direct onto 
the flat wall using wall plugs and no 6 x1” wood 
screws or on a plastic flush mounting single 
conduit box using M3.5 x 14 screws. Check that 
there’s 20mm clearance to the right of the wall-
plate and 25mm above it.   Complete the wiring 
to the MiStat R wallplate in accordance with the 
wiring diagram in step 2, to comply with current 
IEE regulations.  Place the MiStat R onto the 
wallplate and tighten the securing screws. 

Check the 3A fuse, and switch on the mains.

Warning:

 Installing the MiStat R too close to the 

metal side panel or mains cables may interfere 
with the radio signal.

DO NOT 

use a surface 
mounting box

This product is double insulated and 
does not require an earth connection. 
The MiStat R should be wired to the 
boiler or central heating wiring using the 
correct type of cable or flex. The MiStat 
R should be wired to replace hard wired 
room or programmable thermostats, 
as shown on the system or boiler wiring 
diagrams. 

Always check other manufacturers 
instructions for compatibility.

N                  L                   1 

     2                   3

230V AC 50Hz
Fused 3A

Common

heating 

satisfied 

or call for 

cooling

Call for 

heat

Volt free contacts

Combi boiler basic wiring layout

Zone control basic wiring layout

Note:

 If not bound, the bind screen will be visible.

For commissioning see Step 6

Note:

 Only needed if not already bound, ie if 

replacing either the MiStat thermostat or the 
MiStat receiver.

To exit Installer Settings 

Press +/- until ‘DONE’ is shown, then press ‘Select’ or 
press + & – keys for approx. 5 seconds to exit. If there 
is no key pressed for 2 Minutes, the system will exit the 
menu, any changes will be saved.

1. 

Turn on power for the receiver. The red lamp will 
come on. (if green lamp is visible, the device is 
already bound, no further action needed here) 
(If a separate programmer/Timer is fitted, ensure 
that it is switched on)

2. 

Push the button for >5 Seconds and the LED will 
flash red – yellow – green --- -red – yellow - green…

3. 

Enter binding mode on the corresponding 
MiStat room unit, see Step 5: Installer settings , 
item 11 

Important:

 It is essential, that the binding is 

carried out between the corresponding room 
unit and the receiver

4. 

If binding is successful, the signal strength will 
be indicated on both the MiStat room unit and 
the MiStat receiver as follows. If unsuccessful, 
FAILED will be displayed. If POOR SIGNAL 
is displayed, look for a better location. If NO 
SIGNAL is displayed, try connecting again with 
the room unit in a different position.

MiStat Room Unit

MiStat Receiver

Immediately after binding, these signals will indicate 
the signal quality for 1 minute.
• 

three green flashes = Very good signal

• 

double amber flashes = Good signal

• 

single red flashes = Poor signal

• 

steady red = No signal

To check the wireless connection 

A green lamp on the receiver will indicate a good RF 
connection.

To enter Installer Settings 

Press  

+ & –

 keys for  approx. 5 Seconds to enter the 

settings menu as shown.

Note:

 If not bound, the bind screen will be visible.

For commisioning see Step 6

Technical Data

Step 6:

 Commissioning

MiStat C110C & MiStat  R111M

Supply voltage 

MiStat C: 2 x AA 1,5V alkaline 

batteries 

MiStat R: 230V

Switch rating 

MiStat R: 2(1)A 230V a.c.

Ambient 
temperature 

Operating: MiStat C 0°C to 50°C; 

MiStat R 0º to 45ºC

Storage: –20°C to 55°C;

Battery life

MiStat C: 2 years (typically)

Temperature 
range

40°C to 70°C

Control accuracy

+/- 8°C

Wiring

MiStat R: Fixed wiring only, to comply 

with current IEE regulations (BS7671)

MiStat C: No wiring required

MiStat Sensor: Ø0.5mm2 2 core

cable between Sensor & MiStat.

Mounting

MiStat R: Industry standard wallplate

MiStat C: Wall bracket

MiStat Sensor: Direct mounting onto 

cylinder

Radio frequency

868.3 (Bi-directional communication)

Radio signal range

30m typically.  The range may be 

affected by the composition / density 

and number of walls between the 

MiStat C and MiStat R

Pollution degree

2

Software class

A

Rated impulse 
voltage

MiStat R: 2.5kV

Ball pressure test 
temperature

MiStat R: 75°C

Relevant EC 
Directives:

2006/95/EC Low Voltage Directive 

2004/108/EC Electromagnetic 

Compatibility Directive

1995/5/EC R&TTE Directive

2006/66/EC Battery Directive

2011/65/EU RoHS Directive

Applied 
Standards:

EN60730-1; EN60730-2-9
ETSI EN 300 220-3; ETSI EN 301 489-3

eg.

eg.

eg.

eg.

User Code:

 

N     L     1     2      3

           

       

L

 

               

MiStat R

MiStat R

Switched live 

from wiring 

centre

Motorised valve 

To boiler 

and/or 

pump 

Radio signals 

to MiStat R - no wiring

  

230V AC 

fused 3A 

N     L     1     2      3

           

 L  - 
 N - 

Radio signals 

to MiStat R - no wiring

Switched  

230V AC 

fused 3A, 

Internal 

boiler 

electronics 

External 

controls 

connections 

N     L     1     2      3

           

       

L

 

               

MiStat R

MiStat R

Switched live 

from wiring 

centre

Motorised valve 

To boiler 

and/or 

pump 

Radio signals 

to MiStat R - no wiring

  

230V AC 

fused 3A 

N     L     1     2      3

           

 L  - 
 N - 

Radio signals 

to MiStat R - no wiring

Switched  

230V AC 

fused 3A, 

Internal 

boiler 

electronics 

External 

controls 

connections 

If POOR is displayed, look for a better location. 
If NO SIGNAL is displayed, try connecting again with 
the room unit in a different position.

Step 4:

 Mounting Options

The MiStat C should be located in a convenient position 
for the end user, close to the domestic hot water cylinder 
being controlled.

Once the best position has been identified, the MiStat 
C should be fixed to the wall using the wall bracket as 
shown.

MiStat

Wiring

Cylinder Thermostat

External Sensor

Cylinder Thermostat Sensor

Locate the external sensor terminal block on the lower 
edge of the MiStat C thermostat, connect a 2-core 
cable, cut to the required length to reach the sensor 
position. Connect to the sensor in the position shown 
and fold wires back through the cable grip & out 
through the cable entry, re-assemble the housing.

Clip the spacer 
provided onto 
the sensor 
housing

The sensor should be installed approximately one 
third of the way up the hot water cylinder. With pre-
insulated cylinders, mark the position and size, and 
remove just enough insulation to allow the sensor to fit 
against the metal of the cylinder in the recess formed.

The plastic covered spring fixing cable should be cut 
to an un-stretched length of approximately 60-75mm 
(2½”-3”) less than the circumference of the cylinder 
and the hook and eyelet should be screwed into the 
ends. Stretch the cable round the cylinder, over the 
insulation, and position it in the groove across the front 
of the sensor housing, Engage the hook and eyelet.

1/3 cylinder height

Cylinder

Insulation

Fixing cable

Sensor

Sensor

Cylinder

Cable entry

Connect here

NTC 
Sensor

Cable 
grip