background image

Client

Drayton

File Name

7342 Drayton Amends LP20RF 06515085001 ISSB

Artworker

-

Proof Stage

PRINT

Finished Size

A5 148x210mm

Creative Director

Mike Lane

Artwork %

100%

Modification Date

19/03/15 9:21AM

Bleed

3mm

LP20RF & DRF

Radio frequency controlled room thermostat with dual 

channel programmer

Part number RF562DR

Installation & User Guide

For GREENSTAR CDi, GREENSTAR i JUNIOR and GREENSTAR Si MODELS also 

GREENSTAR i SYSTEM and GREENSTAR CDi SYSTEM MODEL(only when used with 

the optional integral diverter).

!

Spares Part number 31003

Spares Part number 22590DR

Summary of Contents for DIGISTAT6RF

Page 1: ...00 Modification Date 19 03 15 9 21AM Bleed 3mm LP20RF DIGISTAT RF Radiofrequencycontrolledroomthermostatwithdual channelprogrammer PartnumberRF562DR Installation UserGuide ForGREENSTARCDi GREENSTARiJUNIORandGREENSTARSiMODELSalso GREENSTARiSYSTEMandGREENSTARCDiSYSTEMMODEL onlywhenusedwith theoptionalintegraldiverter SparesPartnumber31003 SparesPartnumber22590DR ...

Page 2: ... Centigrade IP IngressProtection V Volt m metre mA milliAmpere Definitions DLS BST Summertimebegins LastSundayinMarchat 1 00amGMT Clocksareputforwardby1hour Summertimeends LastSundayinOctoberat 2 00amBST Clocksareputbackby1hour Protectyourenvironment Properbatteryrecycling Electronicdevicesandbatteries rechargeableornot shouldnotbedisposedofintoordinaryhouseholdwaste Instead theymustberecycledprop...

Page 3: ... 9 21AM Bleed 3mm Tableofcontents TechnicalData 2 InstallationGuide 3 LP20RFInstallation 4 WirelessCommissioning SignalStrength 5 6 SignalStrength 7 UserGuide 8 Digistat RFRoomThermostat 9 AdvancedFeatures 10 12 TamperProofing FaultDiagnosis BatteryReplacement 12 LP20RFProgrammer Receiver 13 TheStandardProgram 14 ChangingtheProgram 15 20 Maintenance 21 1 LP20RF DIGISTAT RF 06515085001 ISSB ...

Page 4: ...emounting Wiring Nowiringrequired Classofprotection Degreeofprotection IP30 IP24 Batterybackuptime date 10yearsmin 10yearsmin Shortestswitchingperiod 1minute 1minute EnergyClass IV 2 Acc EU811 2013 812 2013 813 2013 814 2013 PollutionClass 2 2 SoftwareClass A A Ballpressuretest 90 C 90 C TechnicalData RelevantECDirectives 2006 95 ECLowVoltageDirective 2004 108 ECElectromagneticCompatibilityDirecti...

Page 5: ...ends LP20RF 06515085001 ISSB Artworker Proof Stage PRINT Finished Size A5 148x210mm Creative Director Mike Lane Artwork 100 Modification Date 19 03 15 9 21AM Bleed 3mm InstallationGuide LP20RF DIGISTAT RF 3 LP20RF DIGISTAT RF 06515085001 ISSB ...

Page 6: ...singbefore switchingontheelectricalsupplyandboiler J Switchboileronwhencompleted CAUTION Isolatethemainselectricitysupply beforestartinganyworkandobserve allrelevantsafetyprecautions Observeelectro staticdischarge precautions donottouchthepcb circuit DANGER 230voltsdonottouchtheelectrical componentsorcircuits F InstallationGuide LP20RFProgrammer Receiver Clips Cover panel Tab Blanking plate Tab Co...

Page 7: ...ndafterafew secondsthedisplaywillshow rF whichindicates thattheDigistat RFiscontinuouslysendinga signaltotheLP20RF receiver Thereceiverdisplaywillnowshowthe learnt transmittercodeandtheantenna aswellasthe signalstrengthasindicatedbythechevronsonthe righthandsideofthedisplay J Placethetransmitterinthedesiredfinalposition andreturntotheboilertocheckthereceiver display Theidealtransmitterpositionwill...

Page 8: ...atbladedscrewdriver 2 Carefullyinsertthescrewdriverintotheslot locatedatthebackofthedigistatnearthetopand verygentlyleverupwardsafractiontorelease thetabsecuringthefrontofthetransmittertothe backcover Thebackcovercannowbesecuredto thewall 3 Replacethefrontbylocatinginpositionand pushingfullyontothebackcoveruntilthetab engagesatthetopofthetransmitter 4 Retightenthescrewatthebottomoftheunitto fullys...

Page 9: ...nthetransmitter whilere insertingthebatteriesandkeepthebutton depresseduntilthedisplayshows rF 6 30 OFF 6 30 OFF 6 30 OFF 6 30 OFF LEDIndication Chevrons RFStrength Green 4 Verystrong Amber 3 Strong Red 2 Weak None 1 Veryweak Tocancelsignalstrengthmode 1 Removethebatteriesfromthetransmitterto canceltheconstanttransmission 2 Afterafewsecondsthereceiverdisplaywillshow 3 Press OK onthereceiverdisplay...

Page 10: ...UserGuide LP20RF DIGISTAT RF 8 Installation UserGuide 06515085001 ISSB ...

Page 11: ...ators Ifyoudon t haveTRVs youshouldchooseatemperaturethatis reasonableforthewholehouse IfyoudohaveTRVs youcanchooseaslightlyhighersettingtomakesurethat eventhecoldestroomiscomfortable thenpreventany overheatinginotherroomsbyadjustingtheTRVs Roomthermostatsneedafreeflowofairtosensethe temperature sotheymustnotbecoveredbycurtainsor blockedbyfurniture Nearbyfires televisions wallortable lampsmaypreve...

Page 12: ...rrentroomtemperatureasshown Tochangetheuseradjustablesettings 1 ToentertheUsermenu pressandholdtheSET buttonformorethan5butlessthan10secondsthe displaywillshowPr Presettemperaturesetting asshown 2 IfthedialisturnedclockwiseoneclickthenHI Maximumtemperaturesetting willbedisplayed 3 IfturnedonemoreclickclockwisethenLo Minimumtemperaturesetting willbedisplayed NOTE Thisfeaturecanbeusedtoquicklyadjust...

Page 13: ...ldingtheSetbutton formorethan5butlessthan10seconds Prwill beshown 2 Pressthesetbuttonandthedisplaywillshowthe currentPresetsetting 3 RotatethedialclockwisetoincreasethePreset temperature anti clockwisetoreducethePreset temperature 4 PresstheSetbuttontoconfirmandPrwillbe displayed Toreturntonormaloperation eitherpresstheSet buttonformorethan5secondsorwaitfor1minuteand itwillreturnautomatically Chan...

Page 14: ...e anditwillreturnautomatically TamperProofing Totamperprooftheproducti e preventunauthorised adjustmentoftheproduct settheMin andMax HIand Lo temperaturestothesamedesiredvalueusingthe proceduresabove FaultDiagnosis IfthedisplayshowsE1 thefollowingfaultscouldhave occurred 1 Internaltemperaturesensorhasfailed Replace theunit 2 Ambienttemperatureisoutsideproductoperating temperaturerange 0 Cto50 C Wh...

Page 15: ...guideinasafe placeforfuturereference Introduction Theprogrammerwillautomaticallyswitchyourcentral heatingandhotwateronandoffattimesthatsuityou Thegreenlightonthefrontoftheprogrammer shows wheneachoneison LP20RFhasa7 dayprogram allowingfordifferenttimingsoneachdayofthe week withcentralheatingandhotwaterworking independentlyforupto3heatingperiodseachday Iftheengineerhasn tsetyourtimingsforyou your p...

Page 16: ...offirsttimedperiod 6 30am 6 30am 7 00am 7 00am 1stOFF endoffirsttimedperiod 8 30am 8 30am 9 00am 9 00am 2ndON startofsecondtimedperiod 12 00pm 12 00pm 12 00pm 12 00pm 2ndOFF endofsecondtimedperiod 12 00pm 12 00pm 12 00pm 12 00pm 3rdON startofthirdtimedperiod 4 30pm 4 30pm 4 00pm 4 00pm 3rdOFF finalswith offoftheday 10 30pm 10 30pm 11 00pm 11 00pm NOTE TwoON OFFperiodscanbeusedinsteadofthree bysett...

Page 17: ... PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI 6 30 PROG MON TUE WED THU FRI 6 30 PROG OFF HW HW ON MON TUE WED THU FRI 8 30 6 30 PROG PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI 6 30 PROG MON TUE WED THU FRI 6 30 PROG OFF HW HW ON MON TUE WED THU FRI 8 30 6 30 SettingHotWater HW MON FRI 7...

Page 18: ... PROG MON MON MON MON MON MON TUE WED THU FRI PROG PROG 6 30 PROG 6 30 PROG OFF HW HW ON 8 30 6 30 PROG PROG MON MON MON MON MON MON TUE WED THU FRI PROG PROG 6 30 PROG 6 30 PROG OFF HW HW ON 8 30 6 30 5 Press or tochangetheOFFtime 6 Pressset tosettheOFFtimeandselectthenext ONtime 7 PressOKtoselectthefirstONtime Repeatoperations3to6tosetthefirst secondandthird HWON OFFtimes NOTE Afterpressingset f...

Page 19: ...thenext ONtime PROG SAT SUN SAT SUN SAT SUN PROG PROG PROG 9 00 PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT SUN SAT SUN PROG PROG PROG 9 00 PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT SUN SAT SUN PROG PROG PROG 9 00 PROG OFF HW HW ON 9 00 6 30 NOTE Speedupthedisplaybyholdingdownthe or buttons 7 PressOKtoselectthefirstONtime Repeatoperations3to6tosetthefirst secondandthird HWON OFFtimes NOTE Afte...

Page 20: ...NtimeandselecttheOFF time 5 Press or tochangetheOFFtime 6 Pressset tosettheOFFtimeandselectthe nextONtime PROG SAT SUN PROG PROG PROG PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT PROG SAT SUN PROG PROG PROG PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT PROG SAT SUN PROG PROG PROG PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT PROG SAT SUN PROG PROG PROG PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT 7 ...

Page 21: ...edays HDAY HDAY 00 6 30 03 HDAY HDAY 00 6 30 03 HDAY HDAY 00 6 30 03 HDAY HDAY 00 6 30 03 Settingtheclockandtime 1 Presstheset buttonuntilSETandCLOCK are showninthedisplay 2 PressOKtodisplay24hrandON 3 Press toswitchbetween24hrand12hrdisplay 4 Decidebetween24houror12hourdisplayand pressset toselect nowthehourswillflash 5 Press or tosetthecorrecthour 6 Whenthecorrecthourhasbeenselected press set to...

Page 22: ...ATE DATE DATE MON 36 8 08 DATE DATE DATE DATE DATE MON 36 8 08 DATE DATE DATE DATE DATE MON 36 8 08 DATE DATE DATE DATE DATE MON 36 8 08 8 Whenthecorrectdayhasbeenchosen pressset toselect nowdLSwillbedisplayedandONwill flash 9 Press or toswitchbetweenONorOFF Ifyou chooseONthentheclockwillautomaticallyadjust thetimeforDaylightsaving IfyouchooseOFF thenthetimewillnotchangetotakeaccountofthe Daylight...

Page 23: ...nce Theoutercasingcanbewipedcleanusingadrycloth DONOTusepolishordetergents Theseunitscannotbeserviced Shouldtheexistingunitsfailtofunctioncorrectly check thatthe LP20RFReceivertimesandprogramsettingsare correct RFsignallinkissetup Refertopage2forRFsignal rangedetails Digistat RFRoomthermostatbatteriesarethe correcttype fittedcorrectlyandarenotexhausted Fitnewbatteriesifindoubt Digistat RFRoomtherm...

Page 24: ...06515085001ISSB Support Sales 44 0 845 1305522 Technical 44 0 845 1307722 customer care draytoncontrols co uk www draytoncontrols co uk DraytonHeating DraytonControls ...