Installation Guide – 

continued

User Guide – 

continued

What is a programmable room
thermostat?

...an explanation for householders

A programmable room thermostat is both a programmer

and a room thermostat. A programmer allows you to set

‘On’ and ‘Off ’ time periods to suit your own lifestyle. A room

thermostat works by sensing the air temperature, switching

on the heating when the air temperature falls below the

thermostat setting, and switching it off once this set

temperature has been reached. 

So, a programmable room thermostat lets you choose what

times you want the heating to be on, and what temperature

it should reach while it is on. It will allow you to select

different temperatures in your home at different times of the

day (and days of the week) to meet your particular needs.

Turning a programmable room thermostat to a higher

setting will not make the room heat up any faster. How

quickly the room heats up depends on the design of the

heating system, for example, the size of boiler and radiators. 

Neither does the setting affect how quickly the room cools

down. Turning a programmable room thermostat to a lower

setting will result in the room being controlled at a lower

temperature, and saves energy.

The way to set and use your programmable room

thermostat is to find the lowest temperature settings that

you are comfortable with at the different times you have

chosen, and then leave it alone to do its job. The best way to

do this is to set low temperatures first, say 18C, and then 

turn them up by one degree each day until you are

comfortable with the temperatures. You won’t have to adjust

the thermostat further. Any adjustments above these settings

will waste energy and cost you more money.

If your heating system is a boiler with radiators, there will

usually be only one programmable room thermostat to

control the whole house. But you can have different

temperatures in individual rooms by installing thermostatic

radiator valves (TRVs) on individual radiators. If you don’t

have TRVs, you should choose a temperature that is

reasonable for the whole house. If you do have TRVs, you can

choose a slightly higher setting to make sure that even the

coldest room is comfortable, then prevent any overheating in

other rooms by adjusting the TRVs.

The time on the programmer must be correct. Some types

have to be adjusted in spring and autumn at the changes

between Greenwich Mean Time and British Summer Time.

You may be able to temporarily adjust the heating

programme, for example, ‘Override’, ‘Advance’ or ‘Boost’.

These are explained in the manufacturer’s instructions.

Programmable room thermostats need a free flow of air to

sense the temperature, so they must not be covered by

curtains or blocked by furniture. Nearby electric fires,

televisions, wall or table lamps may prevent the thermostat

from working properly.

Hol Man Auto Day

96.5

31

.3

137.0

Technical Data

Model

22083

22087

Power supply

2 X AA 1.5V 

230V AC 50Hz

alkaline batteries

Battery life

3 years typical

Switch rating
Heating (switch N.O.)

16(2)A 230 Vac

Switch type

SPDT (voltage free contacts)

Min. recommended current

10mA @24Vac (inductive)

Ambient temperature

Operating 0°C to 50°C
Storage – 20°C to 85°C

Ambient humidity

Operating 25% to 85%

(non condensing).

Storage 15% to 95%

Temperature range

0°C to 32°C

Accuracy (between 7°C & 32°C) 0.5°C

Timing resolution

1 minute 

Temperature resolution

0.1°C

Rated impulse voltage

2.5KV

Ball pressure test

75°C

Pollution situation

Degree 2

Protection level

IP30

Wiring :

Designed for fixed wiring only, 
to comply with IEE wiring regulations

Dimensions

Installer Options.

If you wish to change any of the Installer Options as shown
below, enter the Installer Option Menu from Auto mode by
pressing < and + simultaneously for 5 seconds.
Pressing < and + again for 5 seconds will exit the Menu and
return to Auto mode. 
Once the Installer Options screen has been selected (Fig 8), the
< and > buttons allow you to scroll through the Menu (shown
below). The + and - allow you to change values. Once a value
has been changed pressing > before exiting the Menu will save
the new setting. (Fig 9 shows Option 1 OFF).

Access protection lock.

The access protection lock allows the installer to lock the

D3

so that the user cannot make any adjustments.

The default is OFF mode allowing the users to adjust the

D3

(see User Guide).

To Lock the 

D3

settings enter the Installer Options Menu

(Refer to Installer Option 1) and select On and press > to accept.
Once the Installer Options Menu is exited all buttons will be
locked.
To switch off the Protection Lock enter the Installer Menu and
change to OFF. Press > to accept.
Once the Installer Menu is exited all buttons will be free to adjust.

Freeze protection.

Freeze protection will switch on the heating if the room
temperature falls to 5ºC and will then control the temperature at
7ºC even if the 

D3

is in OFF mode.

The freeze protection default is ON.
To switch off the Freeze protection mode enter the Installer
Options Menu (Refer to Installer Options 2) and change to OFF.
Press > to accept.

Low and High Limit set points.

The user temperature set points defaults are High 32ºC and Low
7ºC, to change these limits enter the Installer Options Menu
(Refer to Installer Options 3 & 4).

Intelligent Delayed Start (Energy saving feature).

The Intelligent Delayed Start is an energy saving feature which
automatically reduces the warm up time for the heating system.
As the weather becomes milder, Intelligent Start will delay the
heating start times so that fuel is not wasted bringing the room
up to temperature earlier than necessary.
Note: Intelligent Delayed Start only applies in Auto mode.
Intelligent Delayed Start default is in OFF mode.
To switch on Intelligent Delayed Start enter the Installer Options
Menu (Refer to Installer Options 5).
Note the Intelligent Delayed start option is not suitable for
Hydronic underfloor application.
Ensure Installer option 5 is set to Off  before final commissioning
for Hydronic underfloor application.

Valve protection.

In some hydronic heating systems there may be a requirement to
protect the valve by operating it once a day, for a given period
without bringing on the heating system. 
If valve protection is selected the valve will be operated for a
period as shown in Valve protection time (mins).
Valve protection time every day at 10.00am.
Valve protection default is OFF.
To enable the valve protection mode enter the Installer Options
Menu (Refer to Installer Option 6)

Valve protection time (mins).

Valve protection time can be set between 1 and 5 minutes
(default 3 minutes)
To change this once a day on time enter the Installer Options
Menu (Refer to Installer Option 7).

(Fig 9)

Installer
Options

What is it

Select between

Default

1

Access protection lock 

On

Off

Off

2

Freeze protection

On

Off

On

3

Low limit set point ºC

7

High limit

7

4

High limit set point ºC 

Low limit

32

32

5

Delayed start 
(Energy saving feature)

On

Off

Off

6

Valve protection

On

Off

Off

7

Valve protection time (Mins)

1

5

3

8

Sensor fault function

On

Off

Off

9

Application type

1

0

0

Sensor fault function.

When the display shows an error code (E1) or (E2) this indicates
a sensor fault and the heating system will
remain Off.
(E1) = internal sensor and (E2) = external sensor.
If (E1) is shown the 

D3

should be replaced. 

If (E2) is shown, first check the external sensor terminal block
connections before replacing the 

D3

.

Sensor fault function allows you to temporally set the 

D3

to cycle the heating system 30% On and 70% Off until you have
replaced the product.
This can be done by entering the installer Option Menu (Option
8) and selecting On. Press > to accept.
To reset to default Off, entering the installer Option Menu
(Option 8) and selecting Off. Press > to accept.

Application type.

Model 22083

(Battery) can be used for radiator or Hydronic underfloor
applications.
In installer Option select:
0 =

Radiator.

1 =

Hydronic underfloor.

Default 0 = Radiator.

Model 22087

(Mains) can also be used for electric heat applications.
0 =

Radiator and electric heat.

1 =

Hydronic underfloor.

To change application enter the installer Option Menu and refer
to (Option 9).

Drayton – 

D3

7 day 5:2 day Programmable Room

Thermostat 

Allowing different programs for weekdays and weekends and
also every day of the week can be programmed differently.

(Fig 8)

TEAR

HERE

TEAR

HERE

(Fig 11)

(Fig 12)

(Fig 13)

(Fig 14)

(Fig 14a)

(Fig 15)

(Fig 15a)

Pre-set programs for 

D3

7 day 5-2day.

Program 1 (9 till 5) as shown below

Monday to Friday

Events

1

2

3

4

5

6

Time

6:30

8:30

12:00

14:00

16:30

22:30

Temperature C

20.0

16.0

16.0

16.0

21.0

7.0

Saturday and Sunday

Events

1

2

3

4

5

6

Time

7:00

9:00

12:00

14:00

16:00

23:00

Temperature C

20.0

18.0

21.0

18.0

21.0

7.0

Program 2 (Home for lunch)

Monday to Friday

Events

1

2

3

4

5

6

Time

6:30

8:30

12:00

14:00

16:30

22:30

Temperature C

21.0

16.0

21.0

16.0

21.0

10.0

Saturday and Sunday

Events

1

2

3

4

5

6

Time

7:00

9:00

12:00

14:00

16:30

23:00

Temperature C

21.0

18.0

21.0

18.0

21.0

10.0

Program 3 (Home worker)

Monday to Friday

Events

1

2

3

4

5

6

Time

6:00

8:30

12:00

14:00

17:30

22:30

Temperature C

21.0

19.0

21.0

19.0

21.0

16.0

Saturday and Sunday

Events

1

2

3

4

5

6

Time

7:00

9:00

12:00

14:00

16:30

23:00

Temperature C

21.0

18.0

21.0

18.0

21.0

16.0

How to change the pre-set time/temperature program to my
own selection.

Press > to select the day function. Now press + to select the day
or days you wish to change. The days can be selected as blocks or
as individual days (figs 11 to 13).
Fig 11 showing Monday to Friday as one block.
Fig 12 showing Saturday and Sunday as one block.
Fig 13 showing Monday through to Sunday as individual days.

Once you have selected the required day or days, press > to
view the existing time/temperature event (1). (Fig 14) time will
flash. Press > again to view the temperature setting, temperature
will flash. Press > again to view the second time temperature
event (Fig 14a).

When you get to the event you wish to change press + or - to
change the required time, then Press > to accept. Use + or - to
select the required temperature, then > to accept. 

D3

will now show the next time/temperature event. To exit press <
or > until you return to Auto mode. If you continue to press > it
will display all the time/temperature events and move to the
next day, finally going to auto.

How to change User Options.

If you wish to change any user options 1 to 8 shown in table 1
they can be accessed from Auto or Man by pressing < and >
simultaneously for 3 seconds. Once you have accessed the user
setting Menu (Fig 15) press > to scroll through selectable
options 1 to 8. The settings for each option can be changed by
pr or - as required. Press > to accept the change and
move to the next option. To exit press < and > simultaeously for
3 seconds. Alternatively, not pressing any buttons for 2 mins will
cause the 

D3

to return to Auto. (Fig 15a) shows option 1

24 (24 hour clock).
Only selected options which have been accepted by pressing >
will be changed.

How to change from 24hr to 12hr clock (Option 1).

Enter user options, select option 1 and use + and – keys to select
desired option, 12 = 12hr and 24 = 24hr. Press > to accept change.

How to change the default manual set-point temperature
(Option 2).

Enter user options, select option 2 and use + and – keys to set
desired temperature. Press > to accept desired change.

How to change to another predefined program 1, 2 or 3
(Option 3).

Enter user options, select option 3 and use + and – keys to select
desired program 1, 2 or 3. 1 = program 1, 2 = program 2 and 
3 = program 3. Press > to accept desired change.

How to change the number of program events per day
(Option 4).

Enter user options, select option 4 and use + and – keys to select
desired option. 2 = 2 time / temp events per day, 4 = 4 time /
temp events per day and 6 = 6 time / temp events per day. Press
> to accept desired change.

How to switch on/off the automatic summer / winter time
change (Option 5).

Twice a year the actual time is automatically changed to keep it in
line with the summer / winter time change. Default setting is On.
If you wish to disable / enable this feature enter user options,
select option 5 and press – or + key to display Off or On as
desired. Press > to accept desired change.

How to change temperature offset (Option 6).

The temperature displayed on the thermostat may not match
that of other temperature measuring devices in the controlled
space, because of its location. The displayed and set
temperature may be offset to bring it in line with other devices.
To adjust the temperature, enter the user options, select option
6. The temperature may be offset by +/- 5 degrees by pressing
the + and – keys. Press > to accept the desired change.

How to restore the built in time temperature programs
(Option 7).

Enter user options, select option 7 and use + and – keys to
select desired option. Off = current programs retained. On =
restore factory program settings. Press > to select the desired
change. 

Please note enabling this function will lose any user

changes to the preset programs.

How to switch the 

D3

and heating system off

(Option 8).

To switch the 

D3

and the heating system off you need to

enable the Off function. Enter user options, select option 8 and
use + or – keys to select On to enable the Off function .The
thermostat and heating system will now be Off unless the
temperature in the controlled space falls below 7

o

C the frost

protection set-point. The LCD will display Off and room
temperature only and the keys will not function. To switch On
the 

D3

enter user options select option 8 and use + or –

keys to select Off to disable the Off function. The thermostat
will now regulate the heating system in line with the currently
selected program. Please note this does not effect the operation
of domestic hot water where provided.

User
options What is it

Min

Max

Default

1

Change 12h or 24h clock

12

24

24

2

Change the manual set 
point temperature 

0

C

0

C

32 

0

C

20 

0

C

3

Change to another 
pre-set programme

1

3

1

4

Change the number of 
programme events per day

2, 4 or 6

6

5

Switch on/off automatic 
summer/winter time change

On

Off

On

6

Change temperature offset 

0

C

-5

5

0

7

Restore pre-set programme

On

Off

Off

8

To enable Off function

On

Off

Off

(Table 1)

06490044001 D3  27/9/05  11:28  Page 2