SPECIFICATION

Internal Clock Generator

2 x Temperature Compensated Xtal Oscillators (TCXOs)

AES11 GRADE 1 Stability,

+/-1ppm (0-60 Celcius),

Tolerance

<<+/-1ppm (15-30
Celcius)

Phase noise

-130 dBc/Hz @ 1kHz

@ 24.5760 MHz to give Fs

48 kHz, 96 kHz,
192kHz & 384 kHz

@ 22.5792 MHz to give Fs

44.1 kHz, 88.2 kHz,
176.4 kHz & 352.8 kHz

Word Clock Inputs

1 x BNC (Rear Panel)

Input Impedance

75 Ohms

Word Clock Outputs

8 x BNC (Rear Panel)
2 x BNC (Front Panel)

Output impedance

33 ohms

All outputs selectable between

44.1, 48, 88.2, 96, 176.4,
192, 352.8 and 384kHz

General

Power Supply:

Internal, Universal Input, 15 W

Fuse Rating

T315mA for All voltages.
CONFORMING TO: IEC127-2

Fuse Type

20mm x 5mm, Class 3 Slow - Blow
250Volt working

Dimensions:

1u, 19" Rack Mount,
482mm(W) x 44mm(H) x 145mm(D)

Weight

1.755 kg

For warranty service please call Drawmer Electronics Ltd. or
their nearest authorised service facility, giving full details of
the difficulty.

A list of all main dealers can be found on the Drawmer
webpages.

On receipt of this information, service or shipping instructions
will be forwarded to you.

No equipment should be returned under the warranty without
prior consent from Drawmer or their authorised representative.

For service claims under the warranty agreement a service
Returns Authorisation (RA) number will be issued.
Write this RA number in large letters in a prominent position
on the shipping box. Enclose your name, address, telephone
number, copy of the original sales invoice and a detailed
description of the problem.

Authorised returns should be prepaid and must be insured.

All Drawmer products are packaged in specially designed
containers for protection. If the unit is to be returned, the original
container must be used. If this container is not available, then
the equipment should be packaged in substantial shock-proof
material, capable of withstanding the handling for the transit.

CONTACTING 

DRAWMER

Drawmer Electronics Ltd., will be pleased to answer all
application questions to enhance your usage of this
equipment. Please address correspondence to:

Drawmer (Technical Help line)
Coleman Street
Parkgate
Rotherham
S62 6EL
UK

Alternatively contact us by E-mail on :

[email protected]

Further information on all Drawmer dealers, Authorised service
departments and other contact information can be obtained
from our web pages on:

http://www.drawmer.com

M-CLOCK Lite DMS-4 GENERAL INFORMATION

CHAPTER 2

IF A FAULT DEVELOPS

Summary of Contents for M-Clock Lite DMS-4

Page 1: ...ONTENTS Warranty Safety Consideration Radio Frequencies Statement Chapter 1 Introduction Introduction Installation Audio Connections Guide Chapter 2 General Information If a fault develops Contacting Drawmer Specification Block Diagram 2 3 3 4 5 5 6 6 6 7 ...

Page 2: ...ETHER ORAL OR WRITTEN EXPRESSED IMPLIED OR STATUTORY DRAWMER MAKES NO OTHER WARRANTY EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR APARTICULAR PURPOSE OR NON INFRINGEMENT PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE REPAIR OR REPLACEMENT AS SPECIFIED HEREIN IN NO EVENT WILL DRAWMER ELECTRONICS LTD BE LIABLE FOR AN...

Page 3: ...onnected Consult the dealer or an experienced radio TV technician for help Unauthorised changes or modification to this system can void the users authority to operate this equipment This equipment requires shielded interface cables in order to meet FCC class B limit For Canada CLASS B NOTICE This digital apparatus does not exceed the Class B limits for radio noise emissions set out in the Radio In...

Page 4: ...w widely accepted that one of the essential requirements for high quality digital recording is a first class high stability master clock generator These can be complicated devices with many added features which although useful may be surplus to requirements The aim of M Clock Lite is to provide a simple high quality clock generator which is forward compatible with high speed clocks predicted for t...

Page 5: ...the DMS 4 M Clock Lite operates from mains voltages between 85 to 250v eliminating the need to make any changes when touring and allowing the unit to remain fully operational during large fluctuations in the mains power supply The DMS 4 is fitted with a mains fuse that conforms to the IEC127 2 standard and is rated at T315mA If the fuse blows it must be replaced with one of identical type and valu...

Page 6: ...er the warranty without prior consent from Drawmer or their authorised representative For service claims under the warranty agreement a service Returns Authorisation RA number will be issued Write this RA number in large letters in a prominent position on the shipping box Enclose your name address telephone number copy of the original sales invoice and a detailed description of the problem Authori...

Page 7: ...7 BLOCK DIAGRAM Ref 1v01 A 11 02 08 ...

Page 8: ...8 ...