background image

4

DRAWMER

D-Cloc

D-Cloc

D-Cloc

D-Cloc

D-Clock

k

k

k

k-R

-R

-R

-R

-R

DMS-6

DUAL REDUNDANT  WORD CLOCK DISTRIBUTION AMPLIFIER

 

Expanding on the renowned Drawmer D-Clock in providing

word clock measurement and distribution to digital audio
environments the D-Clock-R has been designed with not
only studio recording in mind but also the live and broadcast
environment, where reliability and stability are absolutely
imperative. Designed for fail-safe operation the D-Clock-R
as been developed with dual redundancy for both the
power supplies and also the word clock inputs, ensuring
that the show will go on regardless of technical difficulties.

The Drawmer D-CLock-R is an auto-sensing dual
redundancy input, sixteen output word clock distributor
with a 16 character blue LCD display providing a high
accuracy reference measurement of the incoming sample
rate. It uses a high stability TCXO (temperature
compensated xtal oscillator) along with a microcontroller
to measure the incoming sample rate to an accuracy of
2ppm and displays the information in three different
formats, actual frequency (to one decimal place), nominal
fre/- ppm error, or nominal frequency plus
percentage of pull up or pull down.

The D-Clock-R has two BNC inputs, a default
and auxiliary, which is automatically selected
depending on the strength and quality of the
signal, and capable of locking on to both
word clock (upto 768KHz) and AES-3id (upto
192kHz), it has twelve BNC clock outputs
situated on the rear panel with a further four
BNC clock outputs on the front panel for
quick patching to other digital devices.

CHAPTER 1

INTRODUCTION

Dual Redundancy power supply via 2 x
Universal voltage filtered mains power
inlets for continuous operation & reliability.

Dual Redundant input / 16 output Clock
Measurement and Distribution Amplifier

Inputs: 2 x Auto-Sensing WordClock /
AES3id  BNC dual redundant inputs (@75
Ohms impedance) - should one fail input
is automatically switched to the alternative
source.

Outputs: 16 BNC clock outputs - 33 Ohms
impedance - 4 on the front panel for
convenience.

3 sample rate measurement LCD modes
accurate to 2ppm.

DUAL REDUNDANT INPUTS

Auto-Sensing, auto-switching

inputs provides a fail-safe backup

should one input fail.

TWO INDEPENDENT POWER SUPPLIES

PROVIDE DUAL REDUNDANCY

Can fully operate on a single supply or both (with power load

balancing), providing a fail-safe backup should one fail.

Summary of Contents for D-Clock-R DMS-6

Page 1: ...encies Statement Chapter 1 Introduction Introduction Features Overlay Installation Power Connection Chapter 2 Control Description Simple Connection Guide Audio Connections Control Description Chapter...

Page 2: ...ALL WARRANTIES WHETHER ORAL OR WRITTEN EXPRESSED IMPLIED OR STATUTORY DRAWMER MAKES NO OTHER WARRANTY EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY F...

Page 3: ...sult the dealer or an experienced radio TV technician for help Unauthorised changes or modification to this system can void the users authority to operate this equipment This equipment requires shield...

Page 4: ...one decimal place nominal frequency ppm error or nominal frequency plus percentage of pull up or pull down The D Clock R has two BNC inputs a default and auxiliary which is automatically selected dep...

Page 5: ...heat If the unit is to be used in a mobile situation it is strongly recommended that the rear of the unit is supported in the carrying rack to avoid bending the front panel rack mounting ears Use fib...

Page 6: ...will completely undermine the performance benefits which might be achieved by using a master clock in the first place AES3id calls for unbalanced 75 ohm connections which make its hardware requiremen...

Page 7: ...192KHz The LED s indicate the status of the input sources forbothSync1 Sync2 in word clock A E S 3 i d When a led is lit continuously a strong signal is being received by that input source and the D...

Page 8: ...e your usage of this equipment Please address correspondence to Drawmer Technical Help line Coleman Street Parkgate Rotherham S62 6EL UK Alternatively contact us by E mail on tech drawmer com Further...

Page 9: ...9 BLOCK DIAGRAM Ref 1v00 A 06 03 12...