CONTROL DESCRIPTION

DISPLAY

A Blue/White LCD display wth three switchable modes of operation: 

FREQ

±PPM

 and 

±%.

The mode that is displayed during power down is saved for the next session.
The display accuracy is 2ppm at all sample rates up to 768kHz, or 0.1Hz increments @
48KHz sample rate

MODE

A switch controls the mode of display enabling you to read the incoming sample rate in your
preferred manner. Pressing the switch toggles through the three modes of 

FREQ

±PPM

 and

±%,

 with led indication.

FREQ

Displays the actual frequency to four decimal
places upto >768kHz.

±PPM

Displays the nominal sample rate with +/- ppm
(part per million) error indication for 32, 44.1, 48,
96 & 192KHz

±%

Displays the  nominal sample rate with percentage
pull up/down indication for 32, 44.1, 48, 96 &
192KHz

INPUT SOURCE

CLOCK PRESENT

Sets the input source
to be used - either AES
or BNC as connected
on the rear panel - with
led indication.

The two LED’s indicate the status of the input
sources. When a led is lit continously a strong
signal is being recieved by that input source and
the D-Clock is “locked on”. If a led flickers, the
signal for that particular input source is weak or
unstable - in this case the source of this weak
signal should be located and improved.

Summary of Contents for D-Clock DMS-2

Page 1: ...ntroduction Features Overlay Installation Power Connection Chapter 2 Control Description Simple Connection Guide Audio Connections Control Description Typical Connection Setup Connection Setup for Pro...

Page 2: ...LL WARRANTIES WHETHER ORAL OR WRITTEN EXPRESSED IMPLIED OR STATUTORY DRAWMER MAKES NO OTHER WARRANTY EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FI...

Page 3: ...nsult the dealer or an experienced radio TV technician for help Unauthorised changes or modification to this system can void the users authority to operate this equipment This equipment requires shiel...

Page 4: ...high impedance to maintain the correct level of the digital sig nal for onward distribution Sixteen BNC clock outputs are situated on the rear panel with a further four BNC clock outputs on the front...

Page 5: ...nput 11 12 6 9 7 16x BNC Clock Outputs BufferedBNCwordclockoutputswith 33 Ohms impedance FEATURES OVERLAY The DMS 2 D Clock is designed for standard 19 rack mounting and occupies 1U of rack space Avoi...

Page 6: ...found close to a TV or radio transmitter it is suggested that the screen of the data cable be connected to the chassis connection on the XLR type connector rather than to pin 1 If ground loop problems...

Page 7: ...ual frequency to four decimal places upto 768kHz PPM Displays the nominal sample rate with ppm part per million error indication for 32 44 1 48 96 192KHz Displays the nominal sample rate with percenta...

Page 8: ...8 CONNECTION SETUP FOR PRODUCTS WITH NO CLOCK OUTPUT TYPICAL CONNECTION SETUP...

Page 9: ...mer Technical Help line Coleman Street Parkgate Rotherham S62 6EL UK Alternatively contact us by E mail on tech drawmer com Further information on all Drawmer dealers Authorised service departments an...

Page 10: ...10 BLOCK DIAGRAM Ref 1v00 B 08 06 04...

Reviews: