Draper Paragon V Series Installation & Operating Instructions Download Page 2

Case Dimensions*

Paragon/Series E and V 220V by Draper

Page 2 of 2

Wiring Diagrams

Bottom Closure Removal/Replacement

Removal and replacement of the bottom closure panel 

requires two people positioned about 152 cm from each end 

of the panel. Closure should be handled as shown in Step 5 

below to prevent bowing of the closure during handling.
Before removing 

bottom closure, you 

must first remove 

screws at each end 

of case (see drawing  

at right).

83 mm

83 mm

73 mm

25 mm

3

/

8

" (9.5 mm) dia.

1

/

2

" (12 mm) dia.

73 mm

73 mm

Optional Wall 

Mounting 

Bracket

*Please Note: Optional wall brackets add 4.5 cm per bracket to case 

length. Wall mounting bracket hole location is 2.54 cm from end of case.

www.draperinc.com

(765) 987-7999

MC1

See separate Se-
rial Communication-
RS232 Instruction 
sheet for enabling 
RS232 with the MC1.

Low Voltage and Remote Control

*

* - Case support brackets will be evenly spaced along the case

51

mm

51 mm

57

mm

57

mm

Series V

Viewing

Surface

54

mm

Series E

Viewing

Surface

Varies

305 mm

337

mm

127

mm

203

mm

51 mm

35 mm

Please Note: Do not wire motors in parallel.

Step 1

Step 2

Step 3

Step 4

Step 5

Screw and washer

Tab-Tension 

Adjustment Procedure 

for Paragon

Draper’s Tab-Tensioning System 

is factory-set; under normal 

circumstances field adjustment is 

not required. If you notice wrinkles, 

waves or other indications that 

tensioning cables need adjusting, 

follow these steps:

1

  Determine which side requires  

 adjustment.

2

  Secure dowel with one hand.

Caution: Don't touch or bend 

viewing surface.

3

  Use Phillips-head screwdriver to  

  depress spring-loaded  

  adjustment screw. Slowly turn  

  clockwise to tighten tension or  

  counterclockwise to loosen  

  tension. The screw adjusts in ¼  

  turn increments. Adjust only 

one  

 increment

 (¼ turn) at a time.

4

  If problem is not corrected, leave  

  screen in position for 24 hours to  

  allow surface material to stretch  

  into position.

5

  If problem still is not corrected,  

  repeat steps 2 and 3.

Dowel

Adjustment

Screw

Tensioning

Cable

Neutral

L1

220v, 
50 Hz.

Dashed wiring 
by installer

Control
switch

Single Station Control

CE Approved

Junction box at 

left end of screen

Internal Screen Wiring

Blue-220v (Common)

Brown-220v (Down)

Black-220v (Up)

Dashed wiring 
by installer

Neutral

Hot

Multiple Station Control

Not CE Approved

Cap off with wire
nut & tape

Red

Red

Red

Blue

Blue

Blue

Black

Black

220v, 50 Hz.

Black

Junction box at 

left end of screen

Internal Screen Wiring

Blue-220v (Common)

Brown-220v (Down)

Black-220v (Up)

Green/Yellow (Motor Ground)

Green/Yellow (Motor Ground)

3 Button Wall Switch  

DOWN - Black 

COM - White 

UP - Red 

White or Blue-Common to screen & 110/220V AC Neutral

Red-to screen (directional)

Brown-to screen (directional)

Yellow-to 110/220V AC-Hot

Black-to 110/220V AC-Hot

Green/Yellow (Ground)

Eye Port

 for IR Eye, RF Receiver or LED 

Wall Switch. For more than one of  

these, a splitter is required. 

Aux Port 

for connecting additional LVC-III  

modules (up to six total can be linked- 

connect from Aux to Eye). 

 

Dashed wiring by electrician 

Low voltage wiring by others 

White/Blue (Common)

Red 110/Black 220 (Up)

Black 110/Brown 220 (Down)

Location of key 

operated on-off  

switch if furnished 

To

110/220V

Line

Internal Screen Wiring 

 

STOP 

Control  

Switches 

24v DC 

STOP 

Green/Yellow

(Motor Ground)

RS232 Data FROM Control System 

RS232 Data TO Control System 

Signal Ground & Manual Switch Common 

Manual Switch Down 

Manual Switch Up 

White or Blue-Common

Red-to Screen (directional)

Black-to Screen (directional)

Brown-Hot to AC

Green/Yellow-Ground

Fuse 

Program LED 

Eye Port for IR Eye. For RF Receiver or LED 

Wall Switch, a Splitter and a Power Supply 

is required. Plug RF Receiver or LED Wall  

Switch and Power Supply into splitter, then  

run cable from Splitter to MC1 Eye Port. 

Low Voltage Wiring by others 

AC Wiring by electrician 

MC1 

Location of key 

operated on-off  

switch if furnished 

To AC Line 

White/Blue (Common)

Red 110/Black 220 (Up)

Black 110/Brown 220 (Down)

Internal Screen Wiring 

 

Green 110V/

Green/Yellow 220V

(Motor Ground)

 

 

No. of 

  

Intermediate 

 

Case Width 

Brackets

 

<244 cm 

0

 > 244 and < 457 cm 

1

 > 457 and < 610 cm 

2

 > 610 and < 878 cm 

3

Brackets are equally spaced from each 

other and each end. For example, if the 

case length is 513 cm, then each of the 

two brackets will be placed approxi-

mately 171 cm from each end (with 171 

cm between them).

Caution: Be sure to replace screws 
and washers at each end of case 
when replacing closure!