Case Dimensions*
Paragon by Draper
Page 2 of 2
Wiring Diagrams
Single Station Control
Internal Screen
W
iring
W
hite (Common)
Black (Do
w
n)
Red (Up)
Green (Gro
u
nd)
Dashed
w
iring
b
y electrician
Control
s
w
itch
Single gang
b
ox
b
y others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep
Bl
u
e
Black
Red
Location of key
operated on-off
s
w
itch if f
u
rnished
To 110-120
V
Line
M
u
ltiple Station Control
Internal Screen
W
iring
W
hite (Common)
Black (Do
w
n)
Red (Up)
Green (Gro
u
nd)
Dashed
w
iring
b
y electrician
Red
Red
Black
Bl
u
e
Bl
u
e
Cap off
w
ith
w
ire
n
u
t and tape
Black
Red
Bl
u
e
Black
Single gang
b
ox
b
y others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep.
3 sho
w
n. More or less e
qu
ally
feasi
b
le.
Location of key
operated on-off
s
w
itch if f
u
rnished
To 110-120
V
Line
Bottom Closure Removal/Replacement
Step 1
Step 2
Step 3
Step 4
Step 5
Removal and replacement of the bottom closure panel
requires two people positioned about 5' from each end of
the panel. Closure should be handled as shown in Step 5
below to prevent bowing of the closure during handling.
Scre
w
and
w
asher
Before removing bottom
closure, you must fi rst
remove screws at each
end of case (see drawing
at right).
12"
13
1
/
4
"
5"
8"
2"
1
3
/
8
"
*
* - Case s
u
pport
b
rackets
w
ill
b
e e
v
enly spaced along the case
2"
2"
2¼"
2¼"
3
1
/
4
"
3
1
/
4
"
2
7
/
8
"
1"
3
/
8
" dia.
1
/
2
" dia.
2
7
/
8
"
2
7
/
8
"
Optional Wall Mounting Bracket
*Please Note: Optional wall brackets add 1¾" per bracket to case
length. Wall mounting bracket hole location is 1" from end of case.
www.draperinc.com
(765) 9
8
7-7999
Two-Way Serial Communication (RS232) with MC1
See separate
Serial Commu-
nication-RS232
Instruction sheet
for enabling RS232
w
ith the MC1.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
White-Common to screen & 110-120V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110-120V AC-Hot
Black-to 110-120V AC-Hot
Green-Ground
Eye Port
for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
Aux Port
for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
Dashed wiring by electrician
Low voltage wiring by others
White (Common)
Red (Up)
Black (Down)
Green (Ground)
Location of key
operated on-off
switch if furnished
To 110-120V Line
Internal Screen Wiring
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
White-Common to screen & 110-120V AC Neutral
Red-to Screen (directional)
Brown-to Screen (directional)
Black-Hot to 110-120V AC
Green/Yellow-Ground
Fuse
Program LED
Eye Port for IR Eye. For RF Receiver or LED
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
Low Voltage Wiring by others
AC Wiring by electrician
MC1
Location of key
operated on-off
switch if furnished
To 110-120V Line
White (Common)
Red (Up)
Black (Down)
Green (Ground)
Internal Screen Wiring
Low Voltage & Wireless Control