background image

Dual Roller Motorized FlexShade

®

 

(Large Hardware)

page 7 of 9

Brackets

Section 5 -

 Large Hardware Dimensions

CLOTH WIDTH 

Pocket Headbox

SHADE WIDTH

Large Dual Roller Pocket Headbox Dimensions

8

216mm

8

216mm

6

165mm

7

186mm

2

59mm

3

86mm

3

76mm

22mm

1.6mm  

19mm  

2

60mm  

1

38mm  

2.4mm

Shade Width and Rough Opening will vary depending on motor selection.

7

"

181m

m

4

"

114m

m

Section 6 -

 Electrical Connections

Shade operates on 110-120V, 60 Hz. current. Shade is shipped with internal wiring complete and control switch

(es)

 fully boxed, and standardly supplied with a 6' 

(1.8 m)

 

cable lead. Longer lead can be substituted by removing two screws in motor end of roller, removing lead, plugging new lead in, and replacing screws. Wire to connect 

shade to switch

(es)

 and switch

(es)

 to power supply should be furnished by installer. 

Connections should be made in accordance with attached wiring diagram, and wiring should comply with national and local electrical codes. DO NOT wire motors in 

parallel without written permission from Draper.

All operating switches should be “off” before power is connected.

Please Note:

 For low-voltage wiring requirements, Draper recommends consulting with a professional low-voltage electrical contractor. It is very important that 

shielded and stranded CAT 5 cable be used to prevent any electrical interference.

Please Note:

 A Draper Motor Test Cable 

(Part# 503109)

 and M12 Pigtail 

(Part# C107.089.60)

 are available for temporary power for testing and limit setting. 

 

IMPORTANT:

 To reduce the risk of electric shock, equipment that features a grounding type attachment plug has a third 

(grounding)

 pin on the attachment plug. 

This plug will 

ONLY

 fit into a grounding type outlet. If the plug does not fit into the outlet, a qualified electrician must install the proper outlet.  

Do not change the plug in any way.  

Do not use an extension cord. If the power supply cord is too short, a qualified electrician must install an outlet near the drapery operator.

Summary of Contents for FlexShade DHMO

Page 1: ...eamed Hem OPERATOR END IDLER END OPERATOR END IDLER END M12 Connector Retainer Clip Overview Components CAUTION Read and understand all warnings Page 2 of this document before beginning installation FLEXSHADE DHMO 2 1 PERSONNEL REQUIRED Draper Inc 411 S Pearl St Spiceland IN 47385 draperinc com 765 987 7999 800 238 7999 2021 All Rights Reserved FORM DR_FS_MO_Large_Hardware_Inst21 Dual Roller Motor...

Page 2: ...r workmanship related to the product at place of installation 4 It is the installer s responsibility to make sure appropriate fasteners are used for mounting 5 All brackets fascia headboxes pockets wall clips and other hardware must be installed level Unit must be level and square 6 Never leave the area while operating the unit during installation maintenance or normal operation unless it is secur...

Page 3: ...ng for placement of mounting brackets 2 Drill small starter hole if necessary in mounting surface 3 Mount brackets using appropriate fasteners for surface 4 Place operator motor end of rear shade into its bracket Fig 2 5 Secure motor plate with the provided clips Fig 2 6 Slide notched pin into idler bracket Secure with retainer clip and lock into place with rotating idler lock Fig 3 7 Repeat with ...

Page 4: ...IONAL VENT HOLES POCKET MOUNTING HOLES ENDCAP MOUNTING HOLES Headbox Headbox Closure Panel Closure Panel WALL Brackets mounted to continuous blocking by others secured to building structure Ceiling by others 1 2 page 4 of 9 Dual Roller Motorized FlexShade Large Hardware Section 2 Pocket Headbox Installation PLEASE NOTE Installer must provide adequate clearance for removal of Roller Assembly during...

Page 5: ...ilding Structure Continuous Blocking by others Ceiling by others Wall Clip pre attached to headbox Window WALL 8 216mm 6 165mm 7 186mm 2 59mm 3 86mm 22mm 1 6mm 19mm 2 60mm 1 38mm 3 76mm Closure Panel Figure 3 Section 3 Installing Closure Panel Follow Steps 1 2 Fig 4 Headbox Headbox Closure Panel Closure Panel Figure 4 1 2 ...

Page 6: ...on these motors see instructions packaged with the RS485 Address Limit Setting Tool part C156 241 Section 4 3 Limit Switch Adjustments RTS Motors For limit setting instructions on these motors see Radio Frequency Remote Control Programming Instructions FS_MO_RFRC_ProgInst Section 4 4 Limit Switch Adjustments IntelliFlex I O Motors For limit setting instructions on these motors see instructions pac...

Page 7: ...gram and wiring should comply with national and local electrical codes DO NOT wire motors in parallel without written permission from Draper All operating switches should be off before power is connected Please Note For low voltage wiring requirements Draper recommends consulting with a professional low voltage electrical contractor It is very important that shielded and stranded CAT 5 cable be us...

Page 8: ...0 61 15 5 mm 2 WHITE 2 WHITE 1 BLACK 3 RED 4 GREEN 2 WHITE 2 WHITE 2 WHITE 1 BLACK 3 RED 4 GREEN 2 WHITE W B R G To Switch 120VAC To Motor 60 1 5 m Standard 12 30 5 cm Standard M12 Connector for 4 Wire Motors Ø 0 61 15 5 mm Dashed Wiring by Electrician Controls System Overview Sonesse RTS 120VAC Motors M12 Connector B W G RTS MOTOR 120V 110 120V Line DecoFlex Wire Free Keypad Telis 1 RF Remote STO...

Page 9: ... Dashed Wiring by Electrician Network Device Connector Network Device Connector Network Device Connector Network Device Connector Handheld Remote Wireless Gateway Wall Switch AV Gateway Network Device Connector Contact Closure Interface Controls System Overview 120VAC Motors M12 Connectors B W G 110 120V Line B W G 110 120V Line RS485 120VAC Motor RS485 120VAC Motor stem Overview 120VAC Motors Dat...

Reviews: