Brackets
Section 5 -
Large Hardware Dimensions
CLOTH WIDTH
Pocket Headbox
SHADE WIDTH
Large Dual Roller Pocket Headbox Dimensions
8
216mm
8
216mm
6
165mm
7
186mm
2
59mm
3
86mm
3
76mm
22mm
1.6mm
19mm
2
60mm
1
38mm
2.4mm
Shade Width and Rough Opening will vary depending on motor selection.
7
"
181m
m
4
"
114m
m
Section 6 -
Electrical Connections
Shade operates on 110-120V, 60 Hz. current. Shade is shipped with internal wiring complete and control switch
(es)
fully boxed, and standardly supplied with a 6'
(1.8 m)
cable lead. Longer lead can be substituted by removing two screws in motor end of roller, removing lead, plugging new lead in, and replacing screws. Wire to connect
shade to switch
(es)
and switch
(es)
to power supply should be furnished by installer.
Connections should be made in accordance with attached wiring diagram, and wiring should comply with national and local electrical codes. DO NOT wire motors in
parallel without written permission from Draper.
All operating switches should be “off” before power is connected.
Please Note:
For low-voltage wiring requirements, Draper recommends consulting with a professional low-voltage electrical contractor. It is very important that
shielded and stranded CAT 5 cable be used to prevent any electrical interference.
Please Note:
A Draper Motor Test Cable
(Part# 503109)
and M12 Pigtail
(Part# C107.089.60)
are available for temporary power for testing and limit setting.
IMPORTANT:
To reduce the risk of electric shock, equipment that features a grounding type attachment plug has a third
(grounding)
pin on the attachment plug.
This plug will
ONLY
fit into a grounding type outlet. If the plug does not fit into the outlet, a qualified electrician must install the proper outlet.
Do not change the plug in any way.
Do not use an extension cord. If the power supply cord is too short, a qualified electrician must install an outlet near the drapery operator.