Section 6 -
Electrical Connections
Shade operates on 110-120V, 60 Hz. current. Shade is shipped with internal wiring complete and control switch
(es)
fully boxed, and standardly supplied with a 6’
cable lead. Wire to connect shade to switch
(es)
, and switch
(es)
to power supply, should be furnished by installer. Connections should be made in accordance with
attached wiring diagram, and wiring should comply with national and local electrical codes. DO NOT wire motors in parallel without written permission from Draper.
All operating switches should be “off” before power is connected.
Please Note:
For low voltage wiring requirements, Draper recommends consulting with a professional low voltage electrical contractor. It is very important that
shielded and stranded CAT 5 cable be used to prevent any electrical interference.
Data Cable Pin-Out - RJ45 Connector
MOTOR Pin-Out - RJ9 Connector
4 - GROUND - (BROWN)
3 - POWER + (BLUE)
2 - DATA - (ORANGE)
1 - DATA + (ORANGE/WHITE)
1 - DATA + (ORANGE/WHITE)
2 - DATA - (ORANGE)
3 - N/A (GREEN/WHITE)
4 - POWER + (BLUE)
5 - POWER - (BLUE/WHITE)
6 - N/A (GREEN)
7 - GROUND - (BROWN/WHITE)
8 - GROUND - (BROWN)
Section 7 -
IntelliFlex I/O Components, Wiring and Controls
110-120V Line
Data Cable
with RJ45
Connector
Dashed Wiring
by Electrician
Network
Device Connector
Network
Device Connector
Network
Device Connector
Network
Device Connector
Handheld
Remote
Wireless
Gateway
Wall Switch
AV Gateway
Network
Device Connector
Contact
Closure
Interface
M12
Connectors
RS485
120VAC
Motor
Single gang box
(by others)
Min. 4” x 2
1
/
8
” x 1
7
/
8
” deep
(10 x 5.4 x 48mm)
B
W
G
RS485
120VAC
Motor
Data Cable
with RJ45
Connector
Dashed Wiring
by Electrician
Network
Device Connector
Network
Device Connector
Network
Device Connector
Network
Device Connector
Handheld
Remote
Wireless
Gateway
Wall Switch
AV Gateway
Network
Device Connector
Contact
Closure
Interface
Controls & System Overview
120VAC Motors
M12
Connectors
B W G
110-120V Line
B W G
110-120V Line
RS485
120VAC
Motor
RS485
120VAC
Motor
Controls & System Overview
120VAC Motors
I/O 120V
AC Motor
I/O 120V
AC Motor
page 6 of 8
FlexShade
®
2 Pocket Headbox