- 6-

Transistor hFE Test

1. Set the selector switch to the hFE position.
2. Determine whether the transistor is NPN or PNP.
3. Locate the emitter (E), base (B) or (C)and collect legs into the correct holes in the socket on the

front panel.

4. The display will read the approximate hFE value at the test condition of base current 

10µA VCE 3.2V.

Frequency Measurement

1. Connect the red test lead to the ‘V/

/F’ jack socket and the black lead to the ‘COM’

jack socket.

2. Set the selector switch to the Hz position and the range button to 20KHz.
3. Connect the test leads to the circuit/source to be measured.
4. The frequency value should now be displayed on the digital display.

Note: Readings can be taken from input voltages above 10Vms, but  the accuracy  is not
guaranteed. In noisy environments, it is recommended that shielded cables are used for
measuring small signals.

Capacitance Measurement

1. Set the selector switch to the desired setting within the ‘F’ range (nF or µF).

NOTE: The range control mode in capacitance measurement is manual ranging and only two 
ranges (326nF, 32.6µF) are provided. If the range control button is used in this function 
measurement, decimal points may appear in wrong positions.

2. Before testing the capacitor be sure that the capacitor has been fully discharged.
3. When measuring capacitors with short leads, a testing adaptor has been provided. Insert 

the adaptor into the testing sockets, but remember to remove it before selecting another 
function, to avoid the risk of an electric shock.

4. Once the capacitor has been placed into the testing sockets, the capacitance value will be 

displayed on the digital display.

Continuity Diode Test

1. Connect the red test lead to the V/

/F jack socket and the black lead to the ‘COM’

jack socket.

2. Set the selector switch to the                  position.
3. Connect the test leads to the circuit/source to be tested.
4. If continuity exists (i.e. resistance is less than 50

) the audible buzzer will sound.

Autoranging Feature

1. Ranges for A.C./D.C. voltage, A.C./D.C. amps (µA and mA only), resistance and frequency can 

be measured manually or automatically by following this sequence:

a. Set the selector function switch to the required function.
b. Press the red range button until ‘R-H’ is displayed in the top left hand corner of the LCD screen.
c. To change the range, press the red range button until the desired measurement range is 

displayed.

d. To turn the autoranging feature to manual, depress and hold the red range button down for 

more than three seconds.

Summary of Contents for DMM11

Page 1: ...AUTORANGING MULTIMETER STOCK No 59315 PART No DMM11 12 99 INSTRUCTIONS IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL ...

Page 2: ...only the correct fuse as shown on the rear cover of the meter Fuse is bypassed on 20A setting ensure you refer to point 5 and 6 on page 3 D C Voltage 3 26V 32 6V 326V accuracy 0 3 of rdg 2 digits 326mV 1000V accuracy 0 5 of rdg 2 digits A C Voltage 3 26V 32 6V 326V 750V accuracy 0 8 of rdg 3 digits D C Amps 326µA 3260µA 32 6mA 326mA accuracy 1 3 of rdg 3 digits 10A accuracy 2 0 of rdg 5 digits A C...

Page 3: ...he result of operator error see warning on front page If the meter battery is in need of replacement will appear on the display ACCESSORIES PART No YDMM7 STOCK No 53549 DESCRIPTION Multimeter Crocodile clip and Probe Set PART No YDMM7 STOCK No 53548 DESCRIPTION Spare Probe Set Fig 1 ...

Page 4: ... 3 KNOWYOUR MULTIMETER ...

Page 5: ...et Suitable for both NPN and PNP transistors 8 A C D C Amps or Selecting Button Suitable for diode or continuity testing 9 Range Control Button For selecting measurement reading ranges on LCD display unit 10 Data Hold Button For storing measurement readings in a memory system To clear or cancel the reading automatically turn the autoranging function switch to another function setting OTHER METER M...

Page 6: ...M jack socket For measurements between 200mA and 10A connect the red test lead to the A socket Max 20A 2 Set the selector switch to the desired A C D C range µA mA or A and push the button 3 Open the circuit to be measured and connect the test leads IN SERIES with the load in which current is to be measured See Fig 1 4 Turn on the power to the circuit to be measured the AMPERAGE value should appea...

Page 7: ...nt decimal points may appear in wrong positions 2 Before testing the capacitor be sure that the capacitor has been fully discharged 3 When measuring capacitors with short leads a testing adaptor has been provided Insert the adaptor into the testing sockets but remember to remove it before selecting another function to avoid the risk of an electric shock 4 Once the capacitor has been placed into th...

Page 8: ...Fax 023 8026 0784 Published by Draper Tools Ltd No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior permission in writing from Draper Tools Ltd YOUR DRAPER STOCKIST ...

Reviews: