AeroLift 100 / 150 by Draper, Inc.
page 3 of 4
www.draperinc.com
(765) 987-7999
1
/
8
" Min. clearance
Caution: Make
sure there are
no obstructions
to the AeroLift's
operation
AeroLift Clearance
Limit Switch Adjustments
(Continued)
Caution: It is not uncommon to overheat the motor during initial installation
when setting limits. The motor is thermally protected and will stop working until it
has cooled to a safe temperature before it will start operating again. DO NOT
physically pull the unit down when this occurs.
Adjusting “Down”
(SHOW position)
“Down” position may be adjusted by turning the DOWN limit switch adjustment socket
(see Fig. 2 below). Turning the socket clockwise will stop the AeroLift closer to the ceiling.
Turning it counter-clockwise will cause the lift to stop at a lower point.
Adjusting “Up”
(CLOSED position)
Because the “up” (“closed”) position is preset at the factory, Draper does not recommend
changing this position using the limit switch. The “up” position of the closure may be
changed by changing the length of threaded rod (see Fig. 5). If necessary, however,
“up” position may be adjusted by turning the UP limit switch adjustment socket (see Fig.
2 below). Turning the socket counterclockwise creates a higher, or more fully closed
position. Turning it clockwise creates a lower ‘UP” (closed) position.
Caution: Make sure limit switch is set so that the AeroLift 100/150 motor is NOT
still running after the lift is closed. If it continues to cycle once the lift is closed, a
failure may occur, making the unit descend rapidly and causing damage and/or
injury.
Please Note:
If load is off-center of pan, you may need to adjust the pitch of the
fabric rollers. One setscrew is provided on each end of both fabric rollers (see
above drawing). Use these to adjust roller pitch to keep entire fabric panel taut, so
load is evenly distributed. Use
1
/
8
" hex key to adjust.
Installing Optional Environmental Air Space Housing
The Environmental Air Space Housing is shipped in pieces, and must be
assembled by the installer. The height of the Environmental Air Space Hous-
ing is set by drilling out the knockouts at the desired locations then using
screws to connect side panels. It is recommended that an access panel be
installed in the ceiling to allow future access. The optional environmental air
space housing must be installed to isolate the lift from the “other space used
for environmental air.” Includes trim ring for ceiling opening.
See installation instructions included with Environmental Air Space Housing.
Installing Optional Ceiling Closure
If your AeroLift is equipped with optional ceiling closure, it can be used as
is, or in conjunction with a square of existing ceiling tile.
See installation instructions included with ceiling closure.
Installing Optional Ceiling Trim Kit
The AeroLift is available with a ceiling trim kit, which consists of the lower
section of the Environmental Air Space Housing and the optional closure
panel.
See installation instructions included with Ceiling Trim Kit.
Installing Projector Using Universal Projector Mount
(Maximum Capacity 26 lbs)
See Installation Instructions
included with Universal Pojector Mount.
7"
(178mm)
2½"
(64mm)
10" (254mm)
12" (305mm)
12" (305mm)
5½"
(140mm)
7"
(178mm)
2½"
(64mm)
10" (254mm)
12" (305mm)
12" (305mm)
5½"
(140mm)
JUNCTION BOX
UP LIMIT
DOWN LIMIT
Fabric Roller Adjustment Setscrew
Figure
(2)
Figure
(3)
Figure
(5)