![Draper Access MultiView Installation & Operating Instructions Download Page 1](http://html1.mh-extra.com/html/draper/access-multiview/access-multiview_installation-and-operating-instructions_2528449001.webp)
Bottom flange of Access housing
Bottom access panel pushup
points for panel removal
Installation/Operating Instructions
Access/MultiView Electric Pro jec tion Screen & Masking System by Drap er
Hanging Screen
When locating
v
iewing s
u
rface and checking clearance for screen operation,
remember s
u
rface is centered in the length of the case. Regardless of mo
u
nt-
ing method
u
sed, the following points apply:
➀
Mo
u
nting brackets are packed separately in carton. Engage each bracket
with top of ho
u
sing as shown below and tighten set screws. A bracket
sho
u
ld be within 18" of each end of screen case. Brack ets can be
remo
v
ed and case mo
u
nted with lag screws thro
u
gh top of case (holes
drilled on site).
➁
Screen sho
u
ld be positi
v
ely and sec
u
rely s
u
pported so that
v
ibration or
e
v
en ab
u
si
v
e p
u
lling on
v
iewing s
u
rface or masking will not weaken
installation.
➂
Installer m
u
st ins
u
re that fasteners
u
sed are of adeq
u
ate strength and
s
u
itable for the mo
u
nting s
u
rface chosen. S
u
pporting hardware (chains,
cables, rods, etc.) m
u
st be essentially
v
ertical.
➃
Entire bottom of case m
u
st be readily accessible after installation is
complete.
➄
Front, back and top of case m
u
st be straight—not forced to warp or bow.
➅
If case is painted on location, remo
v
al of roller/fabric assembly is recom-
mended prior to painting. If not remo
v
ed, slot on bottom of case sho
u
ld be
shielded to protect
v
iewing s
u
rface from paint splatters or o
v
erspray.
➆
Do not seal
u
nit in ceiling
u
ntil electrical connections ha
v
e been made
and screen has been operated s
u
ccessf
u
lly.
Electrical Connections
Screen and masking each operate on 110-120
v
, 60 Hz. c
u
rrent.
All connections are made in the j
u
nction box located j
u
st abo
v
e the bottom
access panel at left end of screen. Remo
v
e the bottom access panel for ac-
cess to the j
u
nction box co
v
er (see Bottom Access Panel Remo
v
al in str
u
c -
tions below).
Remo
v
e fo
u
r (4) hex head screws that sec
u
re the co
v
er to the j
u
nction box to
expose two sets of red, black, and white pigtail leads and the green gro
u
nd
wire per wiring diagram on page 4.
If optional low
v
oltage control or
v
ideo interface control is specifi ed and factory
installed for either motor, please refer to wiring diagram on page 3.
Screen is shipped with internal wiring complete and control switch(es) f
u
lly
boxed. Wire to connect screen to switch(es) and switch(es) to power s
u
pply
sho
u
ld be f
u
rnished by installer. Connections sho
u
ld be made in accordance
with attached wiring diagram, and wiring sho
u
ld comply with national and
local electrical codes.
All operating switches should be “off” before power is connected.
Copyright ©2005 Draper Inc. Form AccessMultiView_Inst05
Printed in U.S.A.
Bottom Access Panel Installation/Removal
Bottom access panel hooks o
v
er the lower inside edge of the screen ho
u
sing
and then is pi
v
oted downward
u
ntil the engagement brackets on each end of
the bottom panel click into place with the ball detents on each endcap. Make
s
u
re bottom access panel clicks in place at each end of its length.
Caution
➀
Read instr
u
ctions thro
u
gh completely before proceeding.
➁
Follow instr
u
ctions caref
u
lly. Installation contrary to instr
u
ctions in
v
ali-
dates
warranty.
➂
Entire bottom of screen case sho
u
ld be
u
nobstr
u
cted to permit access
to bottom panel for making electrical connections or ser
v
icing.
➃
Screen sho
u
ld be installed le
v
el (
u
sing a carpenter’s le
v
el).
➄
Nothing sho
u
ld be fastened to screen dowel,
v
iewing s
u
rface or masking.
➅
Operating switches packed separately in screen carton. Do not discard
with packing material.
➆
Screen operates on 110-120
v
, 60 Hz. c
u
rrent.
NOTE:
Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
W
ith
b
ottom access panel
angled up approx. 20 degrees,
engage hook on the panel
w
ith lip of the housing
Using the hook and lip as a pivot,
pull the panel do
w
n
w
ard until the
engagement
b
rackets click into
place
w
ith the
b
all detent
on each endcap
Engagement
b
racket
(one on each end of the
b
ottom access panel)
Remo
v
e bottom access panel by p
u
shing
u
p at each corner of panel
adjacent to slot in bottom of the ho
u
sing. With bottom access panel angled
u
p approximately at 20° it can be lifted off of the lip of the ho
u
sing and then
lowered o
u
t of the ho
u
sing completely.
Access case as seen from below
6
5
/
8
"
7
7
/
16
"
8
"
7
/
8
" electrical
connection hole
standard on
top of case.
1"
¾"
3
7
/
16
"
1
3
/
16
"
Threaded rod
b
y others
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3)
and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
If you encounter any diffi culties installing or servicing your
Access MultiView screen, call your dealer or Draper, Inc.,
Spiceland, Ind., (765) 987-7999; fax (765) 987-7142; or e-mail
[email protected].