background image

- 3 -

CONNECTING YOUR MACHINE TO THE POWER SUPPLY: (240V)

To eliminate the possibility of an electric shock your machine has been fitted with a BS
approved, non rewireable moulded plug and cable which incorporates a fuse, the value
of which is indicated on the pin face of the plug. Should the fuse need to be replaced an

approved BS1362 fuse must be used of the same rating, marked thus

.

The fuse cover is detachable, never use the plug with the cover omitted. If a replacement
fuse cover is required, ensure it is of the same colour as that visible on the pin face of the
plug (i.e. red). Fuse covers are available from your Draper Tools stockist.
If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the cable
should now be suitably prepared and the correct type of plug fitted. See below.

*WARNING:

A plug with bare flexible wires exposed is hazardous if engaged in a live power socket
outlet.

WARNING: THIS APPLIANCE IS DOUBLE INSULATED.

Blue – Neutral, Brown – Live.
As these colours may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured blue must be connected to the terminal which is marked with
the letter ‘N’ or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter ‘L’ or coloured red or brown.

CONNECTING YOUR MACHINE TO THE POWER SUPPLY (110V)

To eliminate the possibility of an electric shock your machine has been fitted with a BS
approved, rewireable plug and cable. If the fitted plug is not suitable, it should be
removed, the end of the cable should be suitably prepared and the correct type of plug
fitted. See below.

WARNING: THIS APPLIANCE IS DOUBLE INSULATED.

Single phase 110 volt machines must be connected using the relevant coding and
matching the colour of the flexible cable to that of the plug. The procedure is as follows:
1. Connect brown coloured core to plug terminal marked letter ‘L’ (live).
2. Connect blue colour core to plug terminal marked letter ‘N’ (neutral).

POWER SUPPLY

WIRING DIAGRAM

DG528

Summary of Contents for 57842

Page 1: ...and safe use We recommend that this manual is read before any operation of the machine before performing any kind of adjustment to the machine and prior to any maintenance tasks By following all the g...

Page 2: ...l Accessories 8 We Draper Tools Ltd Hursley Road Chandler s Ford Eastleigh Hampshire SO53 1YF England Declare under our sole responsibility that the product Stock Number 57842 57843 Part Number DG528...

Page 3: ...e tool If upon inspection it is found that the fault occurring is due to defective materials or workmanship the product will be repaired and tested as soon as possible free of charge normally within f...

Page 4: ...IS DOUBLE INSULATED Blue Neutral Brown Live As these colours may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured blue mu...

Page 5: ...as cutters etc 16 AVOID ACCIDENTAL STARTING Make sure the switch is in the OFF position before plugging the machine into the power supply 17 NEVER LEAVE MACHINE RUNNING UNATTENDED Turn power off Do no...

Page 6: ...5 GETTING TO KNOWYOUR DIE GRINDER 1 Draper Logo 2 Rating Plate 3 Housing Handgrip 4 Switch 5 Head 6 Collet Shaft 7 Collet Nut 8 Spanners 2...

Page 7: ...be used for long periods remember to leave the switch device in the unlocked position GRINDING The grinding point must be perfectly balanced After use the grinding point can be dressed with a grinding...

Page 8: ...arried out by specialized personnel following authorized guidelines In all circumstances Do not abandon in the environment Do not dispose of together with solid urban waste products Contact the specia...

Page 9: ...OPTIONAL ACCESSORIES 8 For a full range of optional accessories please refer to your Draper catalogue...

Page 10: ...NOTES 9...

Page 11: ...NOTES 10...

Page 12: ...0784 HELPLINE 02380 494344 Published by Draper Tools Ltd No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical pho...