Draper 220V Signature/Series E Installation & Operating Instructions Download Page 2

220V Signature/Series E & V by Draper

Single Station Control

CE Approved

Terminal strip in
junction box at left
end of screen

Dashed wiring 
by electrician

Neutr

al

L1

230V, 
50 Hz.

Terminal strip in
junction box at left
end of screen

Dashed wiring 
by electrician

Neutr

al

Hot

Multiple Station Control

Not CE Approved

Cap off with wire
nut & tape

Red

Red

Red

Blue

Blue

Blue

Black

Black

230V, 50 Hz.

Control
switch

Black

PE

Wiring Diagrams

Case Dimensions and Methods of Installation

Page 2 of 2

Do

w

el

Adj

u

stment

Scre

w

Tensioning
Ca

b

le

Draper’s Tab-Tensioning System is factory-set, and 
under normal circumstances will not require fi eld 
adjustment. If, however, you notice wrinkles, waves, or 
other indications that the tensioning cables need to be 
adjusted, follow the procedure below.

  Determine which side requires adjustment.

  Secure dowel with one hand.

Caution: Do not touch or bend surface.

  Using Philips-head screwdriver, depress 

  spring-loaded adjustment screw (see 
  Fig. 1) and slowly turn clockwise to tighten 
  tension, or counterclockwise to loosen tension.
  The screw adjusts in ¼ turn increments. Adjust 
 only 

one increment

 (¼ turn).

  If problem is not corrected, leave screen in position 

  for 24 hours to allow surface material to stretch into position.

  If problem still is not corrected, repeat steps 2 and 3.

Tab-Tensioning Cable Adjustment

Figure 1

www

.draperinc.com

(765) 9

8

7-7999

MC1

See separate Serial Communication-RS232 Instruction sheet for 
enabling RS232 with the MC1.

3 Button Wall Switch 
DOWN - Black
COM - White
UP - Red

Eye Port

 for IR Eye, RF Receiver or LED

Switch For more than one of these, 
a splitter is required.

Aux Port 

for connecting additional

LVC-III modules (up to six total-
connect from Aux to Eye).

Red-to screen (directional)
Brown-to screen (directional)
White-Common to screen, 110-120V AC
Black-to 110-120V AC
Yellow-to 110-120V AC
Green-Ground

Dashed wiring by electrician
Low voltage wiring by others

Terminal strip in
junction box at left
end of screen

230V, 50 Hz.

Neutr

al

Hot

All-Pole Disconnect
by Others

STOP

Control 
Switches
24v DC

STOP

RS232 Data FROM Control System

RS232 Data TO Control System

Signal Ground & Manual Switch Common

Manual Switch Down

Manual Switch Up

Red-to Screen (directional)
Black-to Screen (directional)
Blue-Common
Brown-Hot to 230V AC
Green/Yellow-Ground

Fuse

Program LED

Eye Port for IR Eye. For RF Receiver 
or LED Wall Switch, a Splitter and a 
Power Supply is required. Plug RF 
Receiver or LED Wall Switch and 
Power Supply into splitter, then run 
cable from Splitter to MC1 Eye Port.

Low Voltage Wiring by others

AC Wiring by electrician

MC1

Terminal strip in
junction box at left
end of screen

230V, 50 Hz.

Neutr

al

Hot

All-Pole Disconnect
by Others

STOP

Control 
Switches
24v DC

STOP

Low Voltage & Wireless Control

SCREEN SIZE 

CASE SIZE

Total Drop < 396 cm or viewing width < 366 cm 

Small

Total Drop > 396 cm or viewing width > 366 cm 

Large

NOTE: Viewing surface shown is Series V with tab tensioning. 

Series E, without tab tensioning, is  also available.

Case length

38 mm Typ

Viewing surface

54 mm

A

 Series 

A

 E-small case  81 mm
 E-large case  114 mm
 V  Varies

Ceiling grid 

and tile

(by others)

232

cm

152
mm

248

cm

Audience

Electrical connection
to internal splice box

on left end of case. 22mm

knockout for 13 mm

conduit. J-Box cover located

under splice box.

Shown with

9.5 mm 

threaded rod

(provided

by others).

Ceiling grid and tile

(by others)

Audience

Electrical connection
to internal splice box

on left end of case. 22mm

knockout for 13 mm

conduit. J-Box cover located

under splice box.

Shown with

11 mm 

 threaded

rod (provided

by others).

Ceiling grid and tile

(by others)

232

cm

152
mm

280

cm

Small Signature Case

Large Signature Case