Dranetz HDPQ-DN-MVSTR Quick Reference Manual Download Page 1

 

 

   

 

 

   

 

    

 

 

Quick Reference Guide 

 

HDPQ DataNode with Terminal Block Voltage 

and Hypertronic Current Connectors 

(Dranetz Model HDPQ-DN-MVSTR) 

 

 
 
 

Dranetz   

1000 New Durham Road, Edison, New Jersey 08818 

Telephone 1-800-372-6832 or 732-287-3680 

Fax 732-248-1834 

 

www.dranetz.com

 

Summary of Contents for HDPQ-DN-MVSTR

Page 1: ...DataNode with Terminal Block Voltage and Hypertronic Current Connectors Dranetz Model HDPQ DN MVSTR Dranetz 1000 New Durham Road Edison New Jersey 08818 Telephone 1 800 372 6832 or 732 287 3680 Fax 73...

Page 2: ...ety training on the hazards involved Qualified personnel who work on or near exposed energized electrical conductors must follow applicable safety related work practices and procedures including appro...

Page 3: ...ado ANSI NFPA 70E 2015 de los E E U U y cualquier requisito de seguridad adicional del lugar de trabajo aplicable a su instalaci n AVERTISSEMENT Si l instrument est mal connect la mort des blessures g...

Page 4: ...zugeh rigen Gefahren vertraut ist Qualifiziertes Personal das an bearbeiten oder herausgestellte angezogene elektrische Leiter sich n hern mu anwendbare Sicherheit bezogener Arbeit Praxis und Verfahre...

Page 5: ...trument on live power lines Connections must be made to the instrument first then connect to the circuit to be monitored Wear proper personal protective equipment including safety glasses and insulate...

Page 6: ...ogram 18 Making Measurement Connections 21 Connecting the Voltage and Current Connectors 22 Connecting Current Probes 24 Single Phase 26 Split Phase 27 3 Phase Four Wire Wye 28 3 Phase Floating or Gro...

Page 7: ...e HDPQ DN MVSTR allows you to customize threshold settings for power quality energy and demand It can monitor power quality and energy demand phenomena for troubleshooting and or compliance purposes I...

Page 8: ...nput stated on the unit nameplate can cause damage to the unit La operaci n del HDPQ DataNode desde una fuente de voltaje de ca que no sea la entrada de voltaje nominal indicada en la placa de identif...

Page 9: ...s found at the rear panel of the unit The rear panel for DataNode Model HDPQ DN MVSTR is shown below Power Source The rear panel marking provides information about the input power rating Voltage range...

Page 10: ...ss of power the unit will seamlessly switch to the internal battery backup and will switch back to the normal power source when restored Front Panel The front panel shows the following three 3 LED ind...

Page 11: ...t to Factory Defaults for details on how to manually reset the instrument to factory configuration Power Switch use to turn unit power on or off Power indicator lamp on front panel flashes when unit i...

Page 12: ...the rear panel of the HDPQ DataNode Press in the internal reset button and hold for ten 10 seconds Continue to hold until the Status LED indicator at the front panel stops blinking which indicates tha...

Page 13: ...stablish communications with the server software Refer to the procedures in the next sections to connect to the HDQP DataNode to change communication and other settings In order to connect to the HDPQ...

Page 14: ...the rear panel to turn the instrument ON 4 In order to complete the Ethernet connection the computer IP address needs to be changed to be in the same range as the HDPQ DataNode address Once the compu...

Page 15: ...isplayed Click the Commissioning Setup tab and select Ethernet Setup Result The following screen is displayed 7 On the Commissioning Setup Ethernet Setup screen enter the applicable setting changes an...

Page 16: ...ed connection first to enable and to set up the WiFi connection to the instrument Refer to the previous section Connecting via Wired Ethernet Connection on page 14 and follow Steps 1 to 5 Once the HDP...

Page 17: ...ect from the available WiFi networks on the dropdown menu and then click on the NEXT button to the right 6 Provide the required credentials for the WiFi network you are connecting to Wireless network...

Page 18: ...irements Operating System Category 5e Cable Internet Browser Windows 10 Windows 8 Professional Standard RJ45 connector cross over cable Not Included Internet Explorer 11 x Edge Firefox etc Follow thes...

Page 19: ...address 5 Click on the Get button to populate the left fields with your HDPQ Ethernet Settings Result The following screen opens 6 If you wish to change any of the setting you can edit the field and...

Page 20: ...20 Once the HDPQ DataNode is set up connect to the instrument to verify the settings NOTE You may have to change the Internet settings on your computer to connect...

Page 21: ...de instalaci n y operaci n durante el uso de este instrumento AVERTISSEMENT Si l instrument est mal connect la mort des blessures graves ou un danger d incendie peuvent s en suivre Lisez attentivement...

Page 22: ...onnect to the voltage current input connections Step Action 1 Make sure all circuits are de energized before making connections 2 Connect the data cables Plug the cables into the appropriate connector...

Page 23: ...To reduce the risk of fire electrical shock or physical injury it is strongly recommended to fuse the voltage measurement inputs Fuses must be located as close to circuit connection as possible to max...

Page 24: ...t position of the probe is necessary for correct power measurements where in phase voltage and current measurements are necessary Use only Dranetz current probes and adapter cables for proper operatio...

Page 25: ...EMPLOYEZ PAS les noyaux courants non isol s de sonde autour d un fil nonisol Des sondes de ce type sont concues pour l usage autour des fils isol s seulement L utilisation seulement a compl tement is...

Page 26: ...re important but optional CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation NOTE Be sure to connect the current probe with the arrow on t...

Page 27: ...und measurements are important but optional CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation NOTE Be sure to connect the current probe w...

Page 28: ...nd measurements are important but optional CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation NOTE Be sure to connect the current probe wi...

Page 29: ...nnected to line currents A B and C CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation NOTE Be sure to connect the current probe with the a...

Page 30: ...rrent inputs A and B CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation NOTE Be sure to connect the current probe with the arrow on the ha...

Page 31: ...annels CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation NOTE Be sure to connect the current probe with the arrow on the handle pointing...

Page 32: ...annels CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation NOTE Be sure to connect the current probe with the arrow on the handle pointing...

Page 33: ...tage Accessories Fuse Voltage Adapter for single phase connection FVA 1K1 Fuse Voltage Adapter for three phase connection FVA 1K4 Current Probe Accessories TR Series Current Probes TR 2501B 100mA to 1...

Page 34: ...ANFLEX300MHB 3A 30A 300A 8 DRANFLEX300MHB 3A 30A 300A 12 118430 G1 118431 G1 118432 G1 Input Connector Accessories factory installed Wireless WiFi includes 1 inch antenna not user installable Use for...

Page 35: ...voltage level goes below 1 0 volts The maximum input signal level is 200VDC All logic transitions are time stamped to the millisecond and available for simultaneous comparison to all other data colle...

Page 36: ...the terminal of your monitoring source which serves as the reference Each terminal 1 2 3 4 5 6 7 8 of the instrument connects to the terminal of your monitoring source External Supply If an external...

Page 37: ...Environmental Operating 0 to 55 C 32 to 131 F Storage 40 to 70 C 40 to 158 F Humidity 5 to 95 non condensing Altitude 2000m 6560 ft maximum Installation categories Mains supply Installation Category I...

Page 38: ...for a period of one year from the date of invoice Warranties for products and accessories sold by but not branded as Dranetz are covered by their respective manufacturer s warranties and are not warra...

Page 39: ...area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense Notice Regarding Proprietary Rights This publication contains in...

Page 40: ...40...