background image

SAP LEVEL

L               R

VIDEO IN

AUDIO IN

EAS IN

RF OUTPUT

SAP

OVERMODULATION

SAP AUDIO IN

FUSE

.5 A / 250 V

SLO-BLO

115 VAC, 60 Hz

27 WATT

MADE IN THE U.S.A. BY

SERIAL #

CAUTION:-

RISK OF 

FIRE-REPLACE FUSE AS 
MARKED AFTER
DISCONNECTING
UNIT FROM AC LINE.

ATTENTION:

-RISQUE D'INCENIDE-
REMPLACEZ FUSIBLE DU
TYPE INDIQUÉ APRÉS
DEBRANCHER DU SECTEUR.

®

Rear Panel Controls and Connections     5

R1

R1 - RF OUTPUT
This is the modulator output, 54 to 864 MHz.

R2 - EAS IN Connector
Apply a 44 MHz (45.75 MHz video carrier) signal at
30 dBmV to this input from an EAS IF modulator.  Any level
above +20 dBmV will activate the auto switching circuitry.

R3 - SAP Level *
Adjusts the modulation level of the SAP subcarrier.
Advance level until indicator R5 just illuminates.

R4 - SAP AUDIO IN *
Apply the audio program for the SAP audio channel to this
input.

R5 - SAP OVERMODULATION *
Indicates overmodulation of the SAP audio channel.  Adjust
audio with SAP level control, R3.

R6 - AUDIO IN,  L/R
These are unbalanced audio inputs to the IF circuits.
These “RCA” (phono) connector inputs accept baseband
through 15 kHz audio at a nominal level of 250 mV RMS
(approximately -10 dBu).

R2

R5

R7

R6

R9

R10

R3 R4

R8

R7 - VIDEO INPUT ("RCA" type or "F" type)
These are used as the baseband input to the IF circuits.
Use ONE of these inputs (either the "RCA" or "F" type)
which accepts baseband through 4.2 MHz video at levels
from 0.7 Vp-p to 1.5 Vp-p.

R8 - Fan Vents
To ensure proper cooling of the unit, do not block these
vents for the cooling fan.

R9 - FUSE
Always replace this fuse with one of the same type and
rating: .5 Amp, 250 V SLO-BLO®, 5 x 20 mm type.

R10 - LINE CORD
This is a three-wire power cable.  When the cable is
connected to a properly wired AC power line outlet, this
cable grounds the instrument cabinet.  Connect to a
nominal 115 VAC ±10%, 60 Hz source.  Do not defeat the
safety purpose of the center ground prong on the attached
line cord plug.

Figure 2 - REAR PANEL

SAP option must be installed in the VM2862.

The SAP option may be field installed, by a qualified
technician, into a VM2862.  For purchase information, call
Drake Customer Service at 1 (937) 746-6990.

Summary of Contents for VM2860

Page 1: ...ruction Manual is a registered trademark of the R L Drake Company Copyright 2003 R L Drake Company P N 3852471C 2 2003 Printed in the U S A VM2860 VM2862 Commercial Video Modulator For use in NTSC sys...

Page 2: ...attention to cords at plugs convenience receptacles and the point where they exit from the product 14 Outdoor Antenna Grounding If an outside antenna or cable system is connected to the product be su...

Page 3: ...low noise floor mixing ensures very low broadband noise at the output Thus a full complement of up to all 134 available channels from VM2860 or VM2862 modulators may be combined while maintaining an e...

Page 4: ...POWER Indicator This LED lights when the unit is connected to a source of AC power The LED flashes when on an invalid channel or if there is a synthesizer error F2 VIDEO LEVEL Control The setting of t...

Page 5: ...ese are unbalanced audio inputs to the IF circuits These RCA phono connector inputs accept baseband through 15 kHz audio at a nominal level of 250 mV RMS approximately 10 dBu R2 R5 R7 R6 R9 R10 R3 R4...

Page 6: ...at will shorten component life and modulator performance will be degraded without proper cooling FCC PART 76 612 The VM2860 VM2862 synthesizer has been programmed to comply with FCC requirements for o...

Page 7: ...792 00 798 00 804 00 810 00 816 00 822 00 828 00 834 00 842 00 848 00 854 00 860 00 EIA CH OutputChannel Switch Setting 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27...

Page 8: ...25 175 25 181 25 187 25 193 25 199 25 205 25 211 25 2 3 4 5 6 7 8 9 10 11 12 13 Visual Carrier Frequency MHz VHF BROADCAST CHANNELS VHF BROADCAST CHANNELS VHF BROADCAST CHANNELS VHF BROADCAST CHANNELS...

Page 9: ...th the VM2860 and VM2862 models If the VM2860 model is used with an external stereo encoder that provides the 2 IF LOOP 5 AUDIO LOOP 6 VIDEO LED 7 CLAMP SLOW NORM ON ON 8 4 5 MHz TRAP 3 AUDIO PRE EMPH...

Page 10: ...orking days after it arrives at R L DRAKE if we have all the facts If we must call you it may take longer R L DRAKE is not responsible for damage caused by lightning nonprofes sional alterations acts...

Page 11: ...important to obtain proper performance from this product Therefore carefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE COMPANY determines is due to 1 Improp...

Page 12: ...R L Drake Company 230 Industrial Drive Franklin Ohio 45005 U S A Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 743 4576 World Wide Web Site http www rldrake com...

Reviews: