DRAKE AC1686 Instruction Manual Download Page 3

ii.

Caution Statements

ii.

Important Safety Instructions

iii.

Table of Contents / Specifications

iii.

General Description

2.

Front and Rear Panel Connections and Controls

3.

Installation - Applications

4.

Service / If You Need To Call For Help

5.

Warranty

SPECIFICATIONS

Bandwidth:

Number of Inputs:

Input Impedance:

Input Return Loss:

Input-Input Isolation:

Gain (any input to output):

Input Adjustable Attenuator:

Maximum Input Level:

54 - 860 MHz
16.
75 Ohms (type F connectors).
14 dB, typical.
30 dB minimum, 54 - 550 MHz.
25 dB minimum, 550 - 860 MHz.
3 dB typical, 0 dB minimum,
54 - 550 MHz.
2 dB typical, -1 dB minimum, 550 -
860 MHz.
Front panel setting, 15 dB
minimum range.
+60 dBmV (input attenuator set to
limit output level to rated
maximum), each input.

+48 dBmV each video carrier with
16 equal input NTSC signals.
-60 dBc, 16 channels at output
level of +48 dBmV per channel.
-60 dBc, 16 channels at output
level of +48 dBmV per channel.
14 dB, typical.
-20 dB ±2 dB.
14 VAC/700 mA supplied by
included AC adapter.
120 VAC/60 Hz.
0

0

 C to 50

0

 C, ambient.

19" W x 1.75" H x 4.0" D.
4 Lbs.

Maximum Output Level:

Composite Triple Beat:

Cross Modulation:

Output Return Loss:

Output Test Point:

Power Requirements:

AC Adapter Input:

Operating Temperature:

Size:

Weight:

Output

Level

AC1686

OUTPUT

Monitor Output

Power

Supply

INPUTS 1-16

+60 dBmV

maximum

AC1686 BLOCK DIAGRAM

The AC1686 Active Combiner permits combining the
outputs of up to 16 Audio/Video Modulators, Channel
Processors, etc. onto a single coax.  The unit includes a
low distortion Ga As output amplifier to permit linear
signal output and very low input noise figure.

Attenuator

0-15dB

adjustable

-20 dB

Input

Amp

Low Noise

Ga As Amp

+20 dB

The AC1686 is housed in a standard 1-3/4" H x 19" W
rack space.  A monitor output is provided at the front
panel of the combiner.

Table of Contents/Specifications/General Description      iii

AC1686 ACTIVE COMBINER

POWER

OUTPUT TEST

20 dB

OUTPUT LEVEL

14 VAC

Power Input

Power Indicator

GENERAL DESCRIPTION

TABLE OF CONTENTS

Summary of Contents for AC1686

Page 1: ...Instruction Manual is a registered trademark of the R L Drake Company Copyright 2004 R L Drake Co P N 3853620A 5 2004 Printed in the U S A AC1686 Active Combiner ...

Page 2: ...se of the polarized plug Alternate Warnings If this product is equipped with a three wire grounding type plug a plug having a third grounding pin the plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 1...

Page 3: ...f 48 dBmV per channel 14 dB typical 20 dB 2 dB 14 VAC 700 mA supplied by included AC adapter 120 VAC 60 Hz 00 C to 500 C ambient 19 W x 1 75 H x 4 0 D 4 Lbs Maximum Output Level Composite Triple Beat Cross Modulation Output Return Loss Output Test Point Power Requirements AC Adapter Input Operating Temperature Size Weight Output Level AC1686 OUTPUT Monitor Output Power Supply INPUTS 1 16 60 dBmV m...

Page 4: ...or is approximately 20 dB below the level of the respective signal present at the rear panel RF OUTPUT connector The rear panel output connector must be terminated in 75 Ohms R1 INPUTS 1 16 Connectors These type F connectors accept signals with levels up to 60 dBmV each maximum R2 RF OUT Connector This type F connector provides the single coax output connection of the combined signal inputs With t...

Page 5: ...rmissible output levels for the specific number of combined input channels from 2 16 NUMBER OF COMBINED CHANNELS MAXIMUM PERMISSIBLE OUTPUT LEVELS each channel at RF OUT If these levels are exceeded second and third order distortion products may exceed acceptable levels dBmV 60 55 50 45 40 8CH 16CH 2 3 4 5 6 7 8 9 10 Application Notes 1 Use with 16 modulators with 45 dBmV output levels Set all mod...

Page 6: ...it arrives at R L DRAKE if we have all the facts If we must call you it may take longer R L DRAKE is not responsible for damage caused by lightning nonprofes sional alterations acts of God shipping damage poor storage handling etc R L DRAKE will make note of any shipping damage upon receipt Should your warranty card not be on file at R L DRAKE you will need to send proof of purchase to receive war...

Page 7: ...e are important to obtain proper performance from this product Therefore carefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE COMPANY determines is due to 1 Improper maintenance or repair including the installation of parts or accessories that do not conform to the quality and specifications of the original parts 2 Misuse abuse neglect or improper install...

Page 8: ...R L DRAKE COMPANY 230 INDUSTRIAL DRIVE FRANKLIN OHIO 45005 U S A CUSTOMER SERVICE AND PARTS TELEPHONE 1 937 746 6990 TELEFAX 1 937 743 4576 WORLD WIDE WEB SITE http www rldrake com ...