Replaceable Parts
Make sure to unplug the AC cord before opening the case and replacing parts.
All of these parts can be found on Mouser or Digi-Key.
Fuses
The fuses are small white ceramic fuses with metal ends, housed in an off-white plastic
holder.
Most of the fuses are 375mA, although some one (LIMIT SWITCHES) is 62mA.
375mA: Littelfuse 0154.375DR (0.375A OMNI BLOK 154)
62mA: Littelfuse 0154.062DR (0.062A OMNI BLOK 154)
Trigger Connector
If you lose the green trigger connector (or somehow destroy it) you can order a new
one.
Part: Phoenix Contact #1781043
RJ45 Step/Direction Output Drivers
If the step and direction signals on one or more channels stops working, the problem
could be a blown differential line driver.
Part: TI AM26C31CN
Motor Drivers
If you somehow blow a driver, you can replace it.
Geckodrive G250X with male headers.
Dragonframe DMC+ User Guide
Pg. 12