Connecting the Batteries in Series

 

Why Connect in Series?

 

When batteries are connected in series, current capacities remain the same, but the system voltage is additive. For 
example, two BB

5012

 batteries connected in series form a nominally 24V system (shown in Fig. 4) and should be 

charged using a bulk and absorption voltage of 28.8V, and a float voltage of 27.2V. 

How to Make a Series Connection

 

Note: Battle Born 

BB

5012

 Batteries are capable of being connected in series up to 48V. DO NOT exceed a 48V setup or you will void the 

battery’s warranty

1. Before making any connections, make sure to charge each battery up to 14.6V with a proper lithium charger. ALL

BATTERIES SHOULD BE AT THE SAME STATE OF CHARGE PRIOR TO CONNECTING, otherwise you will encounter
balance issues within your system. You can check your battery’s state of charge with a multimeter.

2.

Identify the positive and negative terminals. These are labeled and color-coded 

red for positive (+)

black for

negative (–).

3. Determine the appropriate finishing hardware set you will use. Verify that your bolt can fully seat into

the nylok insert of the nut. If multiple lugs are used, longer bolts may be required for the bolt to fully seat into
the nylok insert of the nut.

4. Make the proper cable connections to the negative of the first battery. Please reference Fig. 1 for the proper order

of hardware.

5. When connecting to your battery terminals, 

DO NOT 

finger tighten. Use a torque wrench to torque your hardware

to the specification of 9 to 11 ft-lbs. Failure to adequately secure connections can result in severe damage and will
void your warranty.

6. Connect the other end of your cable to the positive terminal of the other battery you are connecting to. Repeat step

4.

7.

Repeat steps 3-6 for additional batteries, but 

DO NOT 

exceed 48V. An example of a correct series

connection can be found below in Fig. 4.

Figure 4: 

Two 

BB

5012

 

Batteries Connected in Series to create a 24V 

5

0Ah

 Battery Bank 

How to Properly Charge the Batteries

 

To properly charge your Battle Born Batteries, you will want to verify that any charging component in your system is 
capable of being programmed for the following specifications. Charging components can include, but are not 
limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc. 

Bulk/Absorption: 14.2V – 14.6V

Absorption Time: 

3

0 minutes per 

100Ah of 

battery

 bank

Float: 13.4V – 13.8V

Equalization: 14.4V/ Disabled

Temperature Compensation: 0/Disabled

NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the 
other items mentioned disabled if applicable. Consult your charger’s manual or the manufacturer

.

 

Summary of Contents for Battle Born Batteries BB5012

Page 1: ...Dragonfly Energy Battle Born Batteries Model BB5012 50Ah 12V Deep Cycle LiFePO4 Battery Manual and Installation Guide Dragonfly Energy Corp Phone 855 292 2831 Email info battlebornbatteries com...

Page 2: ...ruction manual prior to use and installation Table of Contents What is in the Box 2 What Do I Need for Installation 3 Connecting Load Specified Cables to the Batteries 3 Connecting the Batteries in Pa...

Page 3: ...for negative 2 Determine which finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required for the...

Page 4: ...are labeled and color coded red for positive black for negative 2 Determine the appropriate finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut I...

Page 5: ...er cable connections to the negative of the first battery Please reference Fig 1 for the proper order of hardware 5 When connecting to your battery terminals DO NOT finger tighten Use a torque wrench...

Page 6: ...MS will not allow a charging current under 25 F 3 9 C but will continue to discharge down to 4 F 20 C High Current Discharge Surges The BMS in our 50Ah batteries allow for 60A continuous a current of...

Page 7: ...rs or dealers to be free of defects for a period of 10 years the Warranty Period from the date of sale as determined by either the customer s sale receipt the shipping invoice and the battery serial n...

Page 8: ...handise authorization RMA is issued Items 60 days past the original invoice will be reviewed at Battle Born s discretion Returns will not be accepted without an RMA number which can be obtained by fil...

Reviews: