Quick Connect Cylinder Coupling

Self contained breathing apparatus

Approvals

The Dräger quick connect cylinder coupling is approved and certified by NIOSH, and by 

SEI and meets the requirements of NFPA 1981:2007. 

Refer to the User Instructions for the associated self contained breathing apparatus for 

full details of the Approvals.

For your safety

2.1 

General safety statements

●  Strictly  follow  this  User  Instruction  and  the  User  Instruction  supplied  with  the 

associated breathing apparatus.

●  Use of this apparatus requires wearer training, knowledge, observance of these 

User Instructions, and compliance with National Regulations, Laws and Standards, 

governing the use of respiratory apparatus in the country of use.

●  Use the apparatus only for the purpose specified in this User Instruction, or as 

confirmed in writing by Dräger.

●  Only  trained  and  competent  personnel  should  carry  out  the  charging  of  the 

compressed air cylinders.

●  Use only original Dräger Spare Parts for service and maintenance.

●  Notify Dräger in the event of component fault or failure.

2.2 

Definitions of alert icons

Alert icons are used in this document to provide and highlight text that requires a greater 

awareness by the user. A definition of the meaning of each icon is as follows:

 

WARNING

 

Indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  could 

result in death or serious injury.

 

CAUTION

 

Indicates a potentially hazardous situation which, if not avoided, could result in 

physical injury or damage to the product or environment. It may also be used 

to alert against unsafe practices.

 

NOTICE

 

Indicates additional information on how to use the product.

Warranty and liability statement

Terms and Conditions of warranty, for the Dräger Quick Connect Coupling can be found 

in the original Dräger Invoice Document, or can be obtained from Dräger on request.

Responsibility for reliable function of the unit transfers to the owner or operator when 

assembled, serviced, or repaired by untrained personnel, (not employed or authorised 

by Dräger) or when used in a manner not conforming to its intended use.

The  liability  for  the  proper  function  of  the  compressed  air  cylinders  is  irrevocably 

transferred to the owner or operator to the extent that the compressed air cylinders are 

serviced or repaired by personnel not employed or authorised by Dräger Service or if 

the cylinders are used in a manner not conforming to their intended use.

Dräger Safety cannot be held responsible for damage caused by non-compliance with 

the recommendations given above. The warranty and liability provisions of the terms of 

sale and delivery of Dräger Safety are likewise not modified by the recommendations 

given above.

Description and intended use

The Dräger Quick Connect Coupling is designed to replace the conventional threaded 

connection between the first stage pressure regulator of the Dräger PSS

®

 Series self 

contained breathing apparatus and the associated cylinder valve. 

The unit functions as a single action ‘press to connect’ feature that secures the first 

stage  pressure  regulator  to  the  cylinder  valve. This  action  significantly  reduces  the 

cylinder change-over time. 

The Dräger Quick Connect Coupling is available in a choice of two pressure variants, 

i.e. 2216 psig or 4500 psig. Each unit comprises the following elements:
1off    Latching mechanism with handgrip (part of first stage pressure regulator).

1off    Male adaptor (separate screw-on adaptor).

The  Dräger  PSS  Series  with  Dräger  Quick  Connect  Coupling  is  supplied  with  the 

latching mechanism with handgrip already fitted to the first stage pressure regulator of 

the breathing apparatus. The male adaptor is supplied with the breathing apparatus for 

fitting by the user to the associated valve assembly. 

This User Instruction describes the assembly of the male adaptor to the cylinder valve 

and the subsequent use of the Dräger Quick Connect Coupling.

4.1 

Technical data 

 High pressure connections

The  following  self  contained  breathing  apparatus  high  pressure  Quick  Connect 

Couplings are available for associated and suitably modified valves of compressed air 

cylinder assemblies.

●  2216 psig 

●  4500 psig

!

!

i

i

Use

5.1 

Fitting the male adaptor to the valve

Tools Required

Torque Handle c/w 24 mm spanner 

 

                                  3356172

 

NOTICE

 

Adjust the torque handle to a setting of 14-15 lbf ft (18-20 Nm)

 

Refer to Figure 1.

1.  Select a fully charged cylinder and inspect and check that the external thread of the 

cylinder valve port is clean and not damaged. Ensure that the bore of the valve port 

is clean and free from dirt and contamination.

2.  Inspect  and  check  that  the  internal  thread  and  internal  bull  nose  of  the  male 

adaptor (supplied) is clean and not damaged. Ensure that the back-up ring and 

O-ring are in place in the small bore and that the bore is clean and free from dirt 

and contamination.

3.  Screw the male adaptor to the external thread of the cylinder valve port. Securely 

hold the cylinder assembly and then using the torque handle, c/w spanner, tighten 

the male adaptor to the valve to a torque of 14-15 lbf ft (18-20 Nm).

4.  Assembly complete.

5.2 

Fitting the cylinder to the breathing apparatus

 

Refer to Figure 2.

1.  Lay the carrying frame of the breathing apparatus horizontal and fully extend the cylinder 

support strap. Insert the cylinder (valve end first) through the loop of the support strap, 

from the top end of the backplate, and then slide the cylinder aligning the valve with the 

latching mechanism with handgrip of the first stage pressure regulator.

 

i

i

 

Refer to Figure 3.

2.  Pivot  the  pressure  regulator  to  align  the  valve  to  the  bore  of  the  latching 

mechanism.

 

Refer to Figure 4.

3.  Push the valve port (male adaptor) into the bore of the latching mechanism until 

a  positive  ‘click’  is  heard.  The  handgrip  will  rapidly  rotate  approx.  45°  counter 

clockwise indicating that the valve is connected to the pressure regulator.

 