background image

4.6 

Electrical wiring

The Draftbooster must always be connected to an outlet with a protective ground.

•  The wireless outlet should be connected to an appropriately located wall outlet close to the oven and 

chimney. The plug from the Draftbooster can now be connected and the Draftbooster can be controlled 

by the on / off on the remote control. (Check that the Draftbooster can be switched on and off. If not the 

distance between the wireless outlet and the remote control must be reduced

•  If the wireless outlet is not used the plug from the Draftbooster can be pluged directly to a wall outlet. 

Possibly with an on / off switch.

DANGER

If the need arises to replace the original Draftbooster cord, use a cord of the same type. Otherwise, the 

insulation can melt or erode, exposing the cord itself.

4.7 

Start-up

DANGER

Check the oven to make sure it is working properly, while the Draftbooster is running. Make sure that 

no fumes are escaping into the room as this can lead to carbon monoxide poisoning.

1.  Before lighting the fire, turn on the Draftbooster (open the air intake completely on the stove)

2.  Place the wood in the stove

3.  Make sure that the Draftbooster is turned on, before you attempt lighting the fire. Strike a match inside 

the stove and keep it there, noting if the smoke from the match is being drawn towards the top of the 

stove and out of the chimney*

4.  Listen carefully as well. You should be able to hear the blade of the Draftbooster revolving**

5.  Light the fire and make sure that no smoke is escaping from the stove

6.  Close the doors. 

 -Is smoke escaping from the closed stove?

 - Close the air-intake of the stove

 - Open the windows in the room where the oven is located to ventilate the room thoroughly

 - If necessary, call for qualified assistance in order to remedy the problem

 - If defects are detected, these must be repaired before using the Draftbooster and the stove again.

 */** NOTE: If the Draftbooster does not draw the smoke from the match towards the top of the stove, or if you cannot 

hear the Draftbooster running, do not light the fire. Consult the section troubleshooting (section 4.8.2 on page 38). If 

this does not rectify the problem, call for qualified assistance.

CAUTION

Do not over-heat the stove. Small deposits of soot can kindle and start a chimney fire, which may cause 

dangerously high temperatures in the chimney. 

If you have experienced a chimney fire, you must ensure that the mechanical and electrical functioning 

of the Draftbooster is checked. If defects are found, these must be repaired before further use of the 

Draftbooster and the stove.

3120034-DB7-DK-SE-NO-UK-DE

UK • 

37

Summary of Contents for DB7*0 Series

Page 1: ......

Page 2: ......

Page 3: ...roblems by creating a mechanical draught on chimneys with circular core and a maximum internal diameter of ø220 mm The Draftbooster is designed to withstand high temperatures associated with wood burning at a max temperature of 250 C and tolerates continuous operation on stoves and closed inserts The Draftbooster must always be on during start up lighting the fire and during refueling When the ope...

Page 4: ... Impedance protected Yes Max temperature during opera tion C 250 Max temperature at standstill C 250 4 4 1 Precautions 1 Ensure sufficient supply of fresh air in the room where the stove is placed 2 Ensure firm support of the Draftbooster 3 Appropriate precautions must be taken in order to guarantee safe use of heat sources Requirements of supply air Required supply of fresh air must comply with l...

Page 5: ...4 5 Installation 4 5 1 Assembly parts 1 4 x 2 4 x 3 4 x 4 4 x 5 1 x 6 2 x 7 1 x 8 1 x 9 1 x 10 4 x 11 1 x 12 1 x Be aware of sharp and pointy parts 3120034 DB7 DK SE NO UK DE 32 UK ...

Page 6: ...ange adjust the flange legs to fitting the inner diameter of your chimney and fix the legs in this position The example below shows the setting for an inside chimney diameter of ø150 mm The legs must be fastened permanently in the adequate position with the 4 self tapping screws 4 4 4 4 150 180 200 220 3120034 DB7 DK SE NO UK DE UK 33 ...

Page 7: ...4 5 4 Installing the bottom flange and wire on the Draftbooster 3 4 x 9 6 3120034 DB7 DK SE NO UK DE 34 UK ...

Page 8: ... steel wire must always be securely fastened both to the Draftbooster and to the chimney Wrap the wire around the chimney and through the wire lock Tighten the wire in a downward direction and tighten the wire lock The wire must be tight to secure that the Draftbooster stays on the chimney but not so tight that it makes the Draftbooster tilt 7 3120034 DB7 DK SE NO UK DE UK 35 ...

Page 9: ...e Draftbooster and to the chimney Begin by attaching the wire bracket to the chimney tighten the loop and clamp down the wire lock The wire is tightend in a downward direction enough to secure that the Draftbooster stays on the chimney but not so tight that it makes the Draftbooster tilt 8 6 5 3120034 DB7 DK SE NO UK DE 36 UK ...

Page 10: ... the fire Strike a match inside the stove and keep it there noting if the smoke from the match is being drawn towards the top of the stove and out of the chimney 4 Listen carefully as well You should be able to hear the blade of the Draftbooster revolving 5 Light the fire and make sure that no smoke is escaping from the stove 6 Close the doors Is smoke escaping from the closed stove Close the air ...

Page 11: ...rainage holes The manufacturer cannot be held responsible for water penetration into the chimney 4 8 2 Troubleshooting Observation Problem Solution No power supply to the Draftbooster The switch is off Poor electrical connections Check the switch Check and remedy the problem The power supply to the Draftbooster is on but it s not working Poor electrical connections Worn out battery in the remote c...

Page 12: ...attas av denna deklaration överensstämmer m ota tämä selvitys koskee on seuraavien standardien mukainen sem eru meðtalin i staðfestingu Pessari eru i fullu samræmi við eftirtalda staðla sono stati fabbricati in conformità con le norme degli standard seguenti EN60335 1 EN60335 2 80 DS EN ISO 12100 2012 i h t bestemmelser i direktiv in accordance with entsprechen gemäß den Bestimmungen der folgenden...