Device Access Descriptions

16

The 

Device Access

 options, listed in pink on the left side of the web interface, provide options for generating reports,

updating  the  NetGuardian E16 DX G2's firmware, and rebooting the unit.  Click any of the options under 

Device

Access

 to perform the desired action.

The control menu is located in the bottom left of the web interface

Device Access Option

Description

Backup Config

Backs up the units configuration settings

Read

Reads a configuration file from the unit

Write

Commits all changes made in the web interface to the NetGuardian E16 DX G2's non-

volatile memory

Initialize

Sets the unit's configuration to factory default values

Reboot

Reboots  the  NetGuardian E16 DX G2.

Summary of Contents for NetGuardian E16 DX G2

Page 1: ...USER MANUAL NetGuardian E16 DX G2 March 26 2019 D UM X2E16 Firmware Version 1 0A Visit our website at www dpstelecom com for the latest PDFmanual and FAQs...

Page 2: ...tronic or any other means in whole or in part without prior written consent fromDPS Telecom except as required by United States copyright laws The material in this manual is for information purposes a...

Page 3: ...ontrol Relay Connections 7 5 8 Connecting via the USB port 8 10 Bypass Password 9 16 Setting the DCP Address 10 16 Updating Firmware with dsPICLoader 11 17 Updating Firmware via the web 12 18 Operatio...

Page 4: ...rdian NOTE Only a single E16 DX G2 may be connected to a base NetGuardian and it must be the last expansion in a daisy chain Because the E16 DX G2 has only an input serial port and no output serial po...

Page 5: ...314 NetGuardian E16 DX G2 NetGuardian E16 DX G2 User Manual D PK X2E16 D UM X2E16 RJ45 to RJ45 connection cable USB Cable D PR 1028 10C 00 D PR 046 10A 06 23 Rack Ears 19 Rack Ears D CS 325 10A 01 D C...

Page 6: ...use 2 3 4 Amp GMT Operating Temperature 32 140 F 0 60 C Operating Humidity 0 95 non condensing Interfaces Two 50 pin connectors for discrete alarms and control relays 1 RJ45 Ethernet jack not used 1 R...

Page 7: ...ower feeds alarm inputs control outputs and communication lines are on the back panel of the NetGuardian E16 as shown in Figure 4 LAN Connection 6 To connect the unit to LAN insert a standard RJ45 Eth...

Page 8: ...ct discrete alarm inputs 6 Connect control outputs 7 Connect to the NetGuardian 832 or 864 G5 You can connect to the NetGuardian E16 DX G2 through the front panel craft port Please note that the NetGu...

Page 9: ...ower supply Battery lead left and Ground right Grounding Lug left dual power inputs right 1 Insert a battery ground wire into the connector s right terminal Shown above and battery lead into the left...

Page 10: ...7 Communication Lines 7 4 Fig 7 Serial Port is in the lower right corner of the NetGuardian E16 DX G2 s back panel as shown in Figure 7 Fig 8 Serial Port Pinouts...

Page 11: ...nectors Discrete alarms and control relays are connected to the NetGuardian E16 DX G2 using the two 50 pin connectors on the back panel shown in Figure 9 Pinouts for all connections are shown in Figur...

Page 12: ...T 4 CO 5 CT 12 CO 17 GND 11 AM11 36 CT 4 NC 31 CT 12 NC 43 GND 12 AM12 37 CT 4 NO 6 CT 12 NO 18 GND 13 AM13 38 CT 5 NC 32 CT 13 NC 44 GND 14 AM14 39 CT 5 NO 7 CT 13 NO 19 GND 15 AM15 40 CT 5 CO 33 CT...

Page 13: ...use the TTY interface Make sure you are using a standard A B USB cable this same cable is commonly used for USB printers to make a USB craft port connection We ll be using HyperTerminal to connect to...

Page 14: ...11 2 Select Install from a list or specific location Advanced 3 Click Next 4 Select Search for the best driver in these locations 5 Insert NetGuardian Resource Disc CD into your PC 6 Click Browse...

Page 15: ...will confirm installation of a new USB Communications Port 8 Click Finish to close the Wizard Now that the driver has been installed a new COM port is being emulated on your PC Before using hyperterm...

Page 16: ...13 9 Right click the My Computer icon on your desktop then click Manage 10 Click Device Manager in the left pane...

Page 17: ...ch HyperTerminal or other terminal software 12 Click on the Start menu select Programs Accessories Communications HyperTerminal 13 At the Connection Description screen enter a name for this connection...

Page 18: ...ecom NOTE If you don t receive a prompt for your user name and password check the Com port you are using on your PC and make sure you are using the cable provided Additional cables can be ordered from...

Page 19: ...interface Note The default DCP address is 1 Most likely you will not need to change this To connect to the TTY interface connect a serial port on your PC to the front craft port on the E16 DX G2 using...

Page 20: ...DX G2 firmware using dsPICLoader with firmware you have downloaded from dpstele com follow these steps 1 Connect to the USB Port See Connecting via the USB port 2 Select a task file by clicking the br...

Page 21: ...his screen click the Restore Configuration link located in the System Controls section To upload firmware click on Upload on the top right corner of the web interface At the Firmware Load screen simpl...

Page 22: ...ransmitting data on craft port Status Blink Green NetGuardian E16 G2 is monitoring Blink Red Alarms are active Alarm Off No active alarms Blink Red For Future Use Error Blink Green For Future Use Blin...

Page 23: ...rface will then prompt you to either Write your changes to the unit or Reboot the unit for changes to take effect in the top left corner of your browser The relevant options will be highlighted in the...

Page 24: ...it Optional field Location The location of this NetGuardian E16 DX G2 unit Optional field Contact Contact telephone number for the person responsible for this NetGuardian E16 DX G2 unit Optional field...

Page 25: ...e IP you ve already assigned to the unit becomes inactive Using DHCP means the unit will NOT operate in a T Mon environment Unit IP IP address of the NetGuardian E16 DX G2 Subnet Mask A road sign to t...

Page 26: ...arms by indicating if an alarm has been triggered Under the State column the status will appear in red if an alarm has been activated The status will be displayed in green when the alarm condition is...

Page 27: ...e Monitor Controls menu Control Relay Operation ID ID number for the control relay Description Description for the NetGuardian E16 DX G2 s control relay defined in the Provisioning Controls menu State...

Page 28: ...ice Access to perform the desired action The control menu is located in the bottom left of the web interface Device Access Option Description Backup Config Backs up the units configuration settings Re...

Page 29: ...ance is available 24 hours a day 7 days a week For emergency assistance after hours allow the phone to ring until it is answered with a paging message You will be asked to enter your phone number An o...

Page 30: ...hall be commenced and maintained only in Fresno County California In the event suit is brought or an attorney is retained by any party to this Agreement to seek interpretation or construction of any t...

Page 31: ...lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment fr...

Page 32: ...www dpstelecom com 4955 E Yale Fresno CA 93727 559 454 1600 800 622 3314 559 454 1688 fax We protect your network like your business depends on it TM Your Partners in Network Reliability Management...

Reviews: