DPS Telecom NetGuardian 216F User Manual Download Page 1

USER MANUAL

NetGuardian 216F

March 19, 2019

D-UM-NETGF

Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs.

Summary of Contents for NetGuardian 216F

Page 1: ...USER MANUAL NetGuardian 216F March 19 2019 D UM NETGF Visit our website at www dpstelecom com for the latest PDF manual and FAQs...

Page 2: ...fromDPS Telecom except as required by United States copyright laws The material in this manual is for information purposes and is subject to change without notice DPS Telecomshall not be liable for e...

Page 3: ...ptional 66 Block Connector 6 5 3 13 Integrated Temperature and Battery Sensor 6 5 4 14 Analog Dipswitches 6 5 5 15 Data Port 6 5 6 16 6 5 6 1 Connecting NetGuardian Accessories 16 Optional Wire Wrap B...

Page 4: ...Configuration Data via FTP 11 3 4 32 11 3 4 1 Reloading NetGuardian Configuration Data 32 Debug Input and Filter Options 11 3 5 33 Reference Section 12 34 Display Mapping 12 1 34 System Alarms Display...

Page 5: ...units and to what level Ping IP network devices and verify that they re online and operating Optional build would include 4 additional data ports Contact DPS Sales for more information at 800 622 3314...

Page 6: ...onfiguring the NetGuardian using the Windows based Edit216F utility software or the Web Interface Shipping List 3 Please make sure all of the following items are included with your NetGuardian 216F If...

Page 7: ...3 x1 x8 14ft Ethernet Cable D PR 932 10B 14 3 8 Ear Screws 2 000 60375 05 x4 x4 Standard Rack Screws 1 000 12500 06 Metric Rack Screws 2 000 80750 03 x4 x4 Pads 2 015 00030 00 Zip Ties 1 012 00106 00...

Page 8: ...Sensor D PR 998 10A 07 The NetGuardian 216F s external temperature sensor cable for manual hook up Note The NetGuadian 216F also has an internal temperature sensor x2 Pluggable Back Panel D PK 16PAN...

Page 9: ...Guardian 216F Entry Control Unit G2 D PK ECUG2 The Building Access System BAS is a comprehensive building entry management system that can provide centralized door access control to your NetGuardian T...

Page 10: ...face Web browser with multi level security access SNMP Traps to at least 2 masters natively Special amphenol to Wire Wrap termination module Includes our new digital temperature probe on 10 ft lead co...

Page 11: ...Yost RS 232 port 4 RJ45 Yost RS 232 ports optional build 1 50 pin amphenol connectors discretes controls and analogs 1 4 pin screw connector external temp sensor 1 stereo input jack for external temp...

Page 12: ...used Small Standard No 2 Screwdriver Mounting 6 2 The NetGuardian can be flush or rear mounted The NetGuardian mounts in a 19 rack or a 23 rack using the provided rack ears for each size Two rack ear...

Page 13: ...s to the unit have been made 2 Remove the power connector plug from Power Connector A Note that the plug can be inserted into the power connector only one way this ensures that the barrier plug can on...

Page 14: ...g through LAN To connect the NetGuardian 216F to the LAN insert a standard RJ45 Ethernet cable into one of the Ethernet ports From the NetGuardian 216F the connection can be routed via Ethernet to a l...

Page 15: ...1 1 26 ALM 9 9 34 ALM 2 2 27 ALM 10 10 35 ALM 3 3 28 ALM 11 11 36 ALM 4 4 29 ALM 12 12 37 ALM 5 5 30 ALM 13 13 38 ALM 6 6 31 ALM 14 14 39 ALM 7 7 32 ALM 15 15 40 ALM 8 8 33 ALM 16 16 41 Alarm ampheno...

Page 16: ...12 6 5 2 Discretes 1 16 Connector Pinout Diagram Pinout Diagram for Discretes 1 16 connector...

Page 17: ...lock Connector part number D PR 966 10A 00 For 66 block pinout and color code information see diagram below for Discretes 1 16 Note If connecting to a 50 pair split block all connections should be mad...

Page 18: ...4 pin connector Reported as analog channel 2 User Channel 3 Amphenol only Reported as analog channel 3 User Channel 4 Amphenol only Reported as analog channel 4 Monitor Power Feed A Internal Reported...

Page 19: ...it in the on position For normal operation place the dipswitch in the off position Note that the dipswitch is internal and requires the case to be opened in order to change the setting Hot Tip WARNING...

Page 20: ...t RS 485 RJ45 Connector 1 CTS Clear to Send 2 DSR Data Set Ready 3 RXD Receive Data 4 GND Ground 5 GND Ground 6 TXD Transmit Data 7 DTR Data Terminal Ready 8 RTS Request to Send Yost RS 232 RJ45 Conne...

Page 21: ...s and control relays to the wire wrap panel connect themto the pin block on the front of the panel Integrated 10 100 1000BaseT Ethernet Switch 6 7 NetGuardian integrated Ethernet switch The NetGuardia...

Page 22: ...face Blink Green Transmit traffic on LAN interface Serial Blink Red Receive traffic on Serial interface Blink Green Transmit traffic on Serial interface Loop Solid Red Loopback detected on SFP interfa...

Page 23: ...ED Status message descriptions Configuring the NetGuardian 9 The NetGuardian must be provisioned with log on passwords alarm descriptions port parameters ping targets control descriptions and other sy...

Page 24: ...you can connect via the craft port just to configure the NetGuardian s Private LAN IP address and then do the rest of your configuration via a LAN connection via LAN 10 2 NetGuardian LAN Link Once LA...

Page 25: ...ent IP address and subnet mask and write this information down 2 Reset your PC s IP address to 192 168 1 200 3 Reset your PC s subnet mask to 255 255 0 0 You may have to reboot your PC to apply your c...

Page 26: ...mulation software and a connection to the NetGuardian This connection can be a direct connection to the NetGuardian s front panel craft port or a remote connection via Telnet Some initial software con...

Page 27: ...thernet port parameters 1 Once a connection is established the NetGuardian will respond with Password 2 Type the default password dpstelecom then press Enter Note DPS strongly recommends changing the...

Page 28: ...ft port or connect via LAN using a Telnet client with emulation to port 2002 to reach the monitor menu selection This section allows you to do full system monitoring of the NetGuardian including all a...

Page 29: ...e alarms from the M onitor menu A larms option Under Status the word Alarm will appear if an alarm has been activated and Clear will appear if an alarm condition is not present If groups are used the...

Page 30: ...condition is not present The Ping info submenu allows you to change ping targets 11 3 1 3 Monitoring and Operating Relays Controls The NetGuardian comes equipped with 2 relays that can be used to cont...

Page 31: ...are set to measure voltage as the factory default If your sensors output is current change the appropriate analog dipswitch to the current measuring position The scaling worksheet in the provisioning...

Page 32: ...status will be displayed System Alarms can be viewed from the M onitor menu S ystem option 11 3 1 6 Monitoring Data Port Activity View the status of the NetGuardian s data port from the M onitor menu...

Page 33: ...atus and parameters are displayed in the TTY interface The TTY interface displays information about the transceiver such as its Type Vendor Part No and Wavelength as well as diagnostic information on...

Page 34: ...t will take 15 30 seconds after power up for the micro OTDR to run Once micro OTDR runs the vendor name field will change from OpticalZonu Corp to OZC followed by OTDR data 1 The first number after OZ...

Page 35: ...nts for the various alarms include both alarm and clear status Refer to the table for event log field descriptions Note All information in the event log will be erased upon reboot or a power failure M...

Page 36: ...ss Enter 8 After reloading type bye and press Enter to exit Note The backup file name can have a maximumof eight characters before the file extension 11 3 4 1 Reloading NetGuardian Configuration Data...

Page 37: ...Shows Web Browser processing H HDLC debug switch Shows SFP Fiber Interface channel protocol activity i PING toggle switch k Socket toggle switch Shows current dcu resources o Osstart toggle switch Mis...

Page 38: ...etGuardian Expansion 2 Relays 1 8 6193 6200 7193 7200 99 1 16 NetGuardian Expansion 3 Alarms 1 48 6257 6305 7257 7305 99 1 17 NetGuardian Expansion 3 Relays 1 8 6321 6328 7321 7328 Display description...

Page 39: ...ned 8671 9671 32 Undefined 8672 9672 33 Unit Reset 8673 9673 34 Undefined 8674 9674 35 Undefined 8675 9675 36 Lost Provisioning 8676 9676 37 DCP Poller Inactive 8677 9677 38 NET1 not active 8678 9678...

Page 40: ...59 GLD BSU 1 Fail 8699 9699 60 GLD BSU 2 Fail 8700 9700 61 GLD BSU 3 Fail 8701 9701 62 CHAN timeout 8702 9702 63 Craft Timeout 8703 9703 64 Event Que Full 8704 9704 Display 11 System Alarms point des...

Page 41: ...creasing the DCP timer setting under timers or check how long it takes to cycle through the current polling chain on the Master system 38 Ethernet not active The Net1 LAN port is dow n Check LAN cable...

Page 42: ...data 4 K if BAC active Check proxy connection The serial port data may not be getting collected as expected 49 Serial 2 RcvQ full 50 Serial 3 RcvQ full 51 Serial 4 RcvQ full 52 Serial 5 RcvQ full 53 S...

Page 43: ...raps points _OV_vTraps 1 3 6 1 4 1 2682 1 2 0 PointSet 20 PointClr 21 SumPSet 101 SumPClr 102 ComFailed 103 ComRestored 014 P0001Set 10001 through P0064Set 10064 P0001Clr 20001 through P0064Clr 20064...

Page 44: ...9 1 10 1 4 Undefined 99 1 10 5 64 Disp 11 Relays 1 8 99 1 11 1 8 Undefined 99 1 11 9 16 Timed Tick 99 1 11 17 Exp Module Callout 99 1 11 18 Netw ork Time Server 99 1 11 19 Accumulation Event 99 1 11 2...

Page 45: ...CHAN timeout 99 1 11 62 CRFT timeout 99 1 11 63 Event Que Full 99 1 11 64 Alarm point descriptions continued No data indicates that the alarm point is defined but there is no description entered Undef...

Page 46: ...Version Public Request Trap Request 1 3 6 1 4 1 2682 1 2 Enterprise 126 10 230 181 Agent address Enterprise Specific Generic Trap 8001 Specific Trap 617077 Time stamp 1 3 7 1 2 1 1 1 0 Object NetGuar...

Page 47: ...al surrounded by brackets e g IF A received BREAK will appear as BRK Abbreviation Description Abbreviation Description NUL Null DLE Data Link Escape SOH Start of Heading DC Device Control STX Start of...

Page 48: ...t all What s going on A Make sure your using the right COM port settings Your COM port settings should read Bits per second 9600 9600 baud Data bits 8 Parity None Stop bits 1 Flow control None Importa...

Page 49: ...vel or a edge A The NetGuardian s standard configuration is for all alarm points to be level sensed You cannot use configuration software to convert alarm points to TTL edge sensed operation TTL alarm...

Page 50: ...u can also configure up to eight secondary SNMP managers which is configured by selecting the secondary SNMP managers as pager recipients Community strings are configured globally for all SNMP manager...

Page 51: ...traps aren t getting through What should I try A Try these three steps 1 Make sure that the Trap Address IP address of the SNMP manager is defined If you changed the Trap Address make sure you saved...

Page 52: ...serial number ready 3 Have access to troubled equipment Please be at or near your equipment when you call DPS Telecom Technical Support This will help us solve your problem more efficiently 4 Call du...

Page 53: ...for any purpose whatsoever The Software may not be reverse engineered compiled or disassembled No title to or ownership of the Software or any of its parts is transferred to the End User Title to all...

Page 54: ...50...

Page 55: ...51...

Page 56: ...ge 5 operating fromSNMP manager 46 craft port making a craft port connection 20 serial format 44 current draw 5 debug filter 33 debug input 33 dimensions 5 discrete alarminputs capacity 5 display mapp...

Page 57: ...n 2 software configuration guides 2 specifications 5 TTYinterface 1 2 user manual 2 Web Browser interface 1 2 NetGuardian Expansion 5 NVRAM 44 parts 2 numbers 2 ordering 2 power input 5 9 rack ears 2...

Page 58: ...perature external temperature sensor 14 integrated temperature and battery sensor 1 14 specifications 5 TTY Analogs 27 Base Alarms 25 Controls 26 Data Port Activity 28 Ethernet Port 23 menu keys 22 Mo...

Page 59: ......

Page 60: ...rm Management Dependable Powerful Solutions that allow users to monitor larger more complicated networks with a smaller less trained staff www dpstelecom com 4955 E Yale Fresno CA 93727 559 454 1600 8...

Reviews: